The No. 1 ATF temperature sensor converts the fluid temperature into a resistance value for use by the TCM.
The TCM applies a voltage to the temperature sensor through terminal THO1 of the TCM.
The sensor resistance changes with the No. 1 ATF temperature. As the temperature becomes higher, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance and voltage goes down as the temperature becomes higher.
The TCM calculates the fluid temperature based on the voltage signal.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P071011 | Transmission Fluid Temperature Sensor "A" Circuit Short To Ground | When the ignition switch is ON, the No. 1 ATF temperature sensor voltage is below 0.142 V for 0.5 seconds or more (1-trip detection logic). |
·
Short in ATF temperature sensor circuit
·
Transmission wire (No. 1 ATF temperature sensor)
·
TCM |
Comes on | DTC stored | SAE: P0712 |
This DTC indicates a short in the No. 1 ATF temperature sensor circuit. The No. 1 ATF temperature sensor converts the ATF temperature into an electrical resistance value. Based on the resistance, the TCM determines the ATF temperature, and can detect a short in the No. 1 ATF temperature sensor circuit. If the resistance value of the No. 1 ATF temperature sensor is below 79 Ω*, the TCM interprets this as a malfunction of the No. 1 ATF temperature sensor or in the wire harness, illuminates the MIL and stores this DTC.
*: 150°C (302°F) or higher is indicated regardless of the actual ATF temperature.
The ATF temperature can be checked in the Data List.
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON.
Wait for 3 seconds or more with the ignition switch ON.
Enter the following menus: Powertrain / Transmission / Utility / All Readiness.
Input the DTC: P071011.
Check the DTC judgment result.
| GTS Display | Description |
|---|---|
| NORMAL |
·
DTC judgment completed
·
System normal |
| ABNORMAL |
·
DTC judgment completed
·
System abnormal |
| INCOMPLETE |
·
DTC judgment not completed
·
Perform driving pattern after confirming DTC enabling conditions |
| N/A |
·
Unable to perform DTC judgment
·
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit |
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform the Confirmation Driving Pattern and check the DTC judgment result again.
Perform registration and/or initialization when parts related to the automatic transmission are replaced.
DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Warm up the engine.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| A/T Oil Temperature No.1 | ATF temperature sensor value | Min.: -40°C (-40°F) Max.: 150°C (302°F) |
·
Approximately 80°C (176°F): After stall speed test
·
Equal to ambient temperature: While engine is cold |
If value is -40°C (-40°F) or 150°C (302°F), ATF temperature sensor circuit is open or shorted |
| Tester Display |
|---|
| A/T Oil Temperature No.1 |
When DTC P071011 is output and the GTS shows 150°C (302°F) or higher, there is a short circuit.
When DTC P071015 is output and the GTS shows -40°C (-40°F), there is an open circuit.
Check the temperature displayed on the GTS in order to check if a malfunction exists.
| Temperature Displayed | Malfunction |
|---|---|
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or higher | Short circuit |
Warm up the engine.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| A/T Oil Temperature No.1 | ATF temperature sensor value | Min.: -40°C (-40°F) Max.: 150°C (302°F) |
·
Approximately 80°C (176°F): After stall speed test
·
Equal to ambient temperature: While engine is cold |
If value is -40°C (-40°F) or 150°C (302°F), ATF temperature sensor circuit is open or shorted |
| Tester Display |
|---|
| A/T Oil Temperature No.1 |
| Result | Proceed to |
|---|---|
| Data display is within Normal Condition range | A |
| Data display is not within Normal Condition range | B |
A
B
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C36)Location & Routingewd_type=routing;type=c;code=C36 |
||
| C36-52 (THO1) - C36-53 (E2) | Always | 79 Ω to 156 kΩ |
| C36-52 (THO1) - Body ground and other terminals | Always | 10 kΩ or higher |
| C36-53 (E2) - Body ground and other terminals | Always | 10 kΩ or higher |
If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.
| ATF Temperature | Specified Condition |
|---|---|
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
NEXT
Disconnect the transmission wire connector.
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C33,C36)Location & Routingewd_type=routing;type=c,c;code=C33,C36 |
||
| C33-1 (OT+) or C36-52 (THO1) - Body ground and other terminals | Always | 10 kΩ or higher |
| C33-2 (OT-) or C36-53 (E2) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG