Based on the ON-OFF combinations of the solenoid (SL1, SL2, SL3, SL4, SL5, SL6, SC1 and SR) valves, the TCM performs gear shifts from 1st gear to 10th gear.
If a circuit related to a solenoid valve is open or shorted, the TCM uses the fail-safe function to turn other solenoid valves ON or OFF. If an open or short has occurred, the TCM cuts power to the malfunctioning solenoid valve.
The following table shows normal operation of the solenoid (SL1) valve when the shift lever is in D.
| Gear | Solenoid (SL1) Valve |
|---|---|
| 1st | ON |
| 2nd | ON |
| 3rd | OFF |
| 4th | OFF |
| 5th | OFF |
| 6th | ON |
| 7th | ON |
| 8th | OFF |
| 9th | ON |
| 10th | OFF |
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P074512 | Pressure Control Solenoid "A" Circuit Short to Battery | Solenoid (SL1) valve circuit current is higher than specified value for the target current continuously for 1 second or more while driving with gear changes (1-trip detection logic). |
·
Harness and connector
·
Transmission wire
·
Solenoid (SL1) valve
·
TCM |
Comes on | DTC stored | SAE: P0963 |
This DTC indicates a short in the solenoid (SL1) valve circuit. The TCM commands gear shifts by turning the solenoid valves on or off. When there is an open or short in any solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores a DTC.
The TCM performs the fail-safe function and turns the other normal solenoid valves on or off. In case of an open or short circuit, the TCM stops sending current to the open or shorted solenoid.
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for at least 30 seconds.
Perform the D Position Shift Test inspection in Road Test.
Enter the following menus: Powertrain / Transmission / Utility / All Readiness.
Input the DTC: P074512.
Check the DTC judgment result.
| GTS Display | Description |
|---|---|
| NORMAL |
·
DTC judgment completed
·
System normal |
| ABNORMAL |
·
DTC judgment completed
·
System abnormal |
| INCOMPLETE |
·
DTC judgment not completed
·
Perform driving pattern after confirming DTC enabling conditions |
| N/A |
·
Unable to perform DTC judgment
·
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit |
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform the Confirmation Driving Pattern and check the DTC judgment result again.
Perform registration and/or initialization when parts related to the automatic transmission are replaced.
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C36)Location & Routingewd_type=routing;type=c;code=C36 |
||
| C36-6 (SL1+) - C36-25 (SL1-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| C36-6 (SL1+) or C36-25 (SL1-) - Other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
NEXT
Disconnect the transmission wire connector.
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C33,C36)Location & Routingewd_type=routing;type=c,c;code=C33,C36 |
||
| C33-23 (SL1+) or C36-6 (SL1+) - Other terminals | Always | 10 kΩ or higher |
| C33-24 (SL1-) or C36-25 (SL1-) - Other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Solenoid (SL1) Valve |
Remove the solenoid (SL1) valve.
Click hereDrivetrain>AJA0F (AUTOMATIC TRANSMISSION / TRANSAXLE)>VALVE BODY ASSEMBLY>DISASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect a positive (+) lead from the battery with a 21 W bulb to terminal 1 and a negative (-) lead to terminal 2 of the solenoid valve connector. Check that the valve moves and makes an operating sound.
Valve moves and makes an operating sound.
| Proceed to |
|---|
| OK |
| NG |
OK