Home › Power Source / Network › 1HZ (BATTERY / CHARGING) › CHARGING SYSTEM
RM25T0E _57 Power Source / Network _029611 1HZ BATTERY / CHARGING _0134067 CHARGING SYSTEM G

1HZ BATTERY / CHARGING  CHARGING SYSTEM  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.CHECK BATTERY CONDITION

NOTICE:

If the battery is weak or if the engine is difficult to start, recharge the battery and perform inspections again before returning the vehicle to the customer.


a.

Check the battery for damage and deformation. If severe damage, deformation or leakage is found, replace the battery.


b.

Check the electrolyte quantity of each cell.

i.

For maintenance-free batteries:

·

If the electrolyte quantity is below the lower line, replace the battery.

·

If the electrolyte quantity is above the lower line, check the battery voltage when cranking the engine.

If the voltage is below 9.6 V, recharge or replace the battery.


HINT:

Before checking the battery voltage, turn off all the electrical systems (headlights, blower motor, rear defogger, etc.).



ii.

For non-maintenance-free batteries:

·

If the electrolyte quantity is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte's specific gravity.

Standard specific gravity:

1.25 to 1.29 at 20°C (68°F)


·

If the electrolyte quantity is above the lower line, check the battery voltage when cranking the engine. If the voltage is below 9.6 V, recharge or replace the battery.

HINT:

Before checking the battery voltage, turn off all the electrical systems (headlights, blower motor, rear defogger, etc.).





c.

Check the voltage.

i.

Turn the ignition switch off and turn on the headlights for 20 to 30 seconds. This will remove the surface charge from the battery.


ii.

Measure the battery voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
Positive (+) terminal -Negative (-) terminal 20°C (68°F) 12.6 to 12.8 V


HINT:

If the voltage is not as specified, charge the battery.




Hide 28800 2.INSPECT BATTERY TERMINALS, FUSIBLE LINKS AND FUSES

a.

Check that the battery terminals are not loose or corroded.

Torque:
Positive (+) battery terminal : 5.4 N*m (55 kgf*cm, 48 in.*lbf)
Negative (-) battery terminal : 5.4 N*m (55 kgf*cm, 48 in.*lbf)

If the terminals are corroded, clean the terminals.


b.

Measure the resistance of all related fuses.

Standard resistance:

Below 1 Ω


If the result is not as specified, replace fuse.


Hide 16361A 3.INSPECT FAN AND GENERATOR V BELT

Hide 27020 4.INSPECT GENERATOR WIRING

a.

Visually check the generator wiring.

i.

Check that the wiring is in good condition.



Hide 5.INSPECT FOR ABNORMAL NOISES

a.

Listen for abnormal noises from the generator assembly.

i.

Check that no abnormal noises are heard from the generator assembly while the engine is running.



Hide 6.INSPECT CHARGE WARNING LIGHT CIRCUIT

a.

Turn the ignition switch to ON. Check that the charge warning light comes on.


b.

Start the engine and check that the light goes off.

If the light does not operate as specified, troubleshoot the charge warning light circuit.


Hide 7.INSPECT CHARGING CIRCUIT WITHOUT LOAD

A129972C03
2.313,1.99 2.427,1.323 2.427,1.323 2.667,1.323 true 0.333,2.615 0.563,2.771 0.229,0.156 10 false *1 2.552,2.323 2.865,2.521 0.313,0.198 10 false *2 2.698,1.25 3.01,1.448 0.313,0.198 10 false *a
*1 Battery
*2 Generator Assembly
*a Terminal B


a.

If a tester is not available, connect a voltmeter and ammeter to the charging circuit as follows.

i.

Disconnect the wire from terminal B of the generator and connect it to the negative (-) lead of the ammeter.


ii.

Connect the positive (+) lead of the ammeter to terminal B of the generator assembly.


iii.

Connect the positive (+) lead of the voltmeter to the positive (+) terminal of the battery.


iv.

Ground the negative (-) lead of the voltmeter.



b.

Check the charging circuit.

i.

Maintain the engine speed at 2000 rpm and check the reading on the ammeter and voltmeter.

Standard current:

10 A or higher


Standard voltage:
for 12 V type:

13.8 to 14.7 V at 25°C (77°F)

13.2 to 14.0 V at 135°C (275°F)

for 24 V type:

27.7 to 28.7 V at 25°C (77°F)

26.0 to 28.7 V at 135°C (275°F)


If the result is not as specified, replace the generator assembly.

HINT:

If the battery is not fully charged, the ammeter reading will sometimes be more than the standard current.




Hide 8.INSPECT CHARGING CIRCUIT WITH LOAD

a.

With the engine running at 2000 rpm, turn the high beam headlights on and turn the heater blower switch to the HI position.


b.

Check the reading on the ammeter.

Standard current:
for 12 V type:

30 A or higher

for 24 V type:

15 A or higher


If the ammeter reading is less than the standard current, repair the generator assembly.

HINT:

If the battery is fully charged, the indication will sometimes be less than the standard current.

In this case, increase electrical load by operating devices such as the wiper motor and rear window defogger. Then recheck the reading on the ammeter.