Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › SPIRAL CABLE › 2014.08–2016.08
RM25T0E _58 Vehicle Interior _029929 SUPPLEMENTAL RESTRAINT SYSTEMS _0137999 SPIRAL CABLE G

SUPPLEMENTAL RESTRAINT SYSTEMS  SPIRAL CABLE  INSPECTION  


PROCEDURE

Hide 84306 1.INSPECT SPIRAL CABLE SUB-ASSEMBLY

NOTICE:

As the spiral cable sub-assembly may break, do not rotate the spiral cable sub-assembly more than the specified amount.


a.

Visually check for defects with the spiral cable sub-assembly.

i.

The defects are as follows:

·

Scratches

·

Small cracks

·

Dents

·

Chips

·

Cracks or other damage to the connector


OK:

No defects are found.


If any of the defects is found, replace the spiral cable sub-assembly with a new one.



b.
B374340C01
1.865,0.26 2.188,0.469 0.323,0.208 0.438,1.198 0.76,1.406 0.323,0.208 1.26,4.208 1.583,4.417 0.323,0.208 2.042,4.271 2.365,4.479 0.323,0.208 2.01,3.99 1.927,3.469 true 2.135,4 2.25,3.49 true 1.302,3.729 1.188,3.375 true 0.073,0.094 0.385,0.25 0.313,0.156 10 false *a 1.948,0.281 2.26,0.479 0.313,0.198 10 false Z1 0.531,1.219 0.844,1.417 0.313,0.198 10 false Z2 2.094,4.281 2.406,4.479 0.313,0.198 10 false L29 1.313,4.219 1.625,4.417 0.313,0.198 10 false L27 1.74,3.354 2.052,3.552 0.313,0.198 10 false D+ 2.271,3.354 2.583,3.552 0.313,0.198 10 false D- 0.948,3.281 1.26,3.479 0.313,0.198 10 false HO
*a Component without harness connected
(Spiral Cable Sub-assembly)


Check the spiral cable.

i.

Set the spiral cable sub-assembly to the center position.

Click hereVehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>SPIRAL CABLE>INSTALLATION


ii.

Measure the resistance between each terminal of the spiral cable sub-assembly according to the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L29-1 (D+) - z2-2 Always 3 Ω or less
L29-2 (D-) - z2-1
L27-8 (HO) - z1-1



iii.

After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise, and measure the resistance as shown in the table below. Then rotate the spiral cable sub-assembly 5 times counterclockwise, and measure the resistance as shown in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L29-1 (D+) - z2-2 Always 3 Ω or less
L29-2 (D-) - z2-1
L27-8 (HO) - z1-1



iv.

After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise. Then while rotating the spiral cable sub-assembly 5 times counterclockwise, measure the resistance as shown in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L29-1 (D+) - z2-2 Always 3 Ω or less
L29-2 (D-) - z2-1
L27-8 (HO) - z1-1


If the result is not as specified, replace the spiral cable sub-assembly.