27020 1.INSTALL GENERATOR ASSEMBLY
Temporarily install the generator assembly with the 2 bolts.
Attach the 2 wire harness clamps.
Connect the generator connector.
Connect the generator wire with the nut.
Install the terminal cap.
16361A 2.INSTALL FAN AND GENERATOR V BELT
88310A 3.INSTALL NO. 1 V BELT (w/ Air Conditioning System)
28800 4.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
5. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL
When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART