| *1 | CLEAN AIR FILTER | *2 | AIR FILTER CASE |
| ● | Non-reusable part | - | - |
Use the same procedure for RHD and LHD vehicles.
The procedure listed below is for LHD vehicles.
87130K
1.INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY
2.INSTALL COVER PLATE
| *a | Upper Fan Door Lever | *b | Fitting Surface of Upper Fan Door Lever |
| *c | Lower Fan Door Lever | *d | Fitting Surface of Lower Fan Door Lever |
| *e | Gears of cover plate and No. 1 blower damper servo sub-assembly aligned in standard position. | *f | Check Hole |
With the gears of the cover plate and No. 1 blower damper servo sub-assembly aligned in the standard position as shown in the illustration, attach the cover plate to the guide while moving the lever so that the point of engagement on the upper fan door lever and the point of engagement of the lower fan door lever enter the check holes.
The upper fan door lever engagement cannot be checked from point of engagement with the check hole on the front surface of the cover plate. Therefore, look through the gap to check the engagement.
Install the cover plate with the 4 screws.
87127C
3.INSTALL NO. 1 BLOWER MOTOR SUB-ASSEMBLY PACKING
|
|
87103B
4.INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY
5.INSTALL AIR FILTER SUB-ASSEMBLY
| *1 | Clean Air Filter | *2 | Air Filter Case |
|
Install in this Direction | - | - |
Attach the guide and install the clean air filter to the air filter case as shown in the illustration.
Align with the direction of the UP mark and install.
Install the air filter sub-assembly as shown in the illustration.
Insert it with the arrow of the UP mark facing upward.
88899M
6.INSTALL AIR FILTER COVER PLATE
|
|
87429B
7.INSTALL NO. 1 COOLER UNIT PACKING
| *a | Reference Line | *b | Wrap Portion |
|
Apply in this Direction | - | - |
Remove the peeling paper on a new No. 1 cooling unit packing trying not to touch the adhesional surface and install it to the blower assembly.
Check that any remaining No. 1 cooling unit packing has been completely removed from the blower assembly.
Attach so that there are no gaps in the entire circumference.
Start application from the reference line and follow the direction of the arrow.
Wrap and attach the No. 1 cooling unit packing. Do not cut it.
88539C
8.INSTALL NO. 2 COOLER UNIT DRAIN HOSE