If there is a communication malfunction between the EV control ECU and ID code box (immobiliser code ECU), or when the communication ID codes do not match, the EV control ECU stores this DTC.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Priority | Note |
|---|---|---|---|---|---|---|
| B279986 | Engine Immobiliser System Signal (Some Circuit Quantity, Reported via Serial Data) Invalid | Either of the following conditions is met (1 trip detection logic*):
·
A malfunction is detected in the communication or communication lines between the EV control ECU and ID code box (immobiliser code ECU). ·
The communication ID codes of the EV control ECU and ID code box (immobiliser code ECU) do not match. |
·
ID code box (immobiliser code ECU) ·
EV control ECU ·
Harness or connector |
EV | A | DTC output confirmation operation (Perform either of the following):
·
Start the hybrid control system and wait for 10 seconds. If there is a malfunction, the hybrid control system will stop (communication begins within 3 seconds of the hybrid control system start, and DTCs are stored after 6 seconds). ·
Connect the cable to the negative (-) auxiliary battery terminal, start the hybrid control system and wait for 10 seconds (communication begins within 3 seconds of the ignition switch being turned to ON, and DTCs are stored after 6 seconds). |
*: Only output while a malfunction is present.
| Vehicle Condition when Malfunction Detected | Fail-safe Operation when Malfunction Detected |
|---|---|
| Hybrid control system cannot be started | - |
| DTC No. | Data List and Active Test |
|---|---|
| B279986 | - |
When using the GTS with the ignition switch off, connect the GTS to the DLC3 and turn a courtesy light switch on and off at intervals of 1.5 seconds or less until communication between the GTS and the vehicle begins. Then select Model Code "KEY REGIST" under manual mode and enter the following menus: Body Electrical / Entry&Start. While using the GTS, periodically turn a courtesy light switch on and off at intervals of 1.5 seconds or less to maintain communication between the GTS and the vehicle.
The entry and start system (for Start Function) uses the LIN communication system and CAN communication system. Inspect the communication function by following How to Proceed with Troubleshooting. Troubleshoot the entry and start system (for Start Function) after confirming that the communication systems are functioning properly.
When replacing the EV control ECU or ID code box (immobiliser code ECU), refer to the Service Bulletin.
After repair, confirm that no DTCs are output by performing "DTC Output Confirmation Operation".
When DTC B279986 and a certification ECU (smart key ECU assembly) DTC are output simultaneously, first perform troubleshooting for the certification ECU (smart key ECU assembly) DTC.
Register the communication ID codes.
Refer to Service Bulletin.
| Proceed to |
|---|
| NEXT |
NEXT
Using an oscilloscope, check the waveform.
| *A | for LHD | *B | for RHD |
| *a | Component with harness connected
(EV Control ECU) |
*b | Waveform |
| *c | Approximately 160 ms. | *d | Approximately 270 ms. |
| Tester Connection | Condition | Tool Setting | Specified Condition |
|---|---|---|---|
|
*1: for LHD *2: for RHD |
|||
|
Click Location & Routing(A8,D15)Location & Routingewd_type=routing;type=c,c;code=A8,D15 Click Connector(A8)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A8;pinno=29 Click Connector(D15)Instrument Panel>Instrument Panel Wire>EV Control ECUewd_type=component;type=c;code=D15;pinno=29 |
|||
| A8-29 (IMO) - Body ground*1
D15-29 (IMO) - Body ground*2 |
Within 3 seconds of hybrid control system start or within 3 seconds of ignition switch turned to ON after cable disconnected and reconnected to auxiliary battery | 2 V/DIV., 500 ms./DIV. | Pulse generation
(See waveform) |
| Result | Proceed to |
|---|---|
| Normal waveform | A |
| Terminal IMO stuck low (2.4 V or less) | B |
| Waveform length or shape is abnormal, or IMO terminal stuck at Hi (12 V) | C |
A
B
C
Using an oscilloscope, check the waveform.
| *A | for LHD | *B | for RHD |
| *a | Component with harness connected
(EV Control ECU) |
*b | Waveform |
| *c | Approximately 160 ms. | *d | Approximately 270 ms. |
| Tester Connection | Condition | Tool Setting | Specified Condition |
|---|---|---|---|
|
*1: for LHD *2: for RHD |
|||
|
Click Location & Routing(A8,D15)Location & Routingewd_type=routing;type=c,c;code=A8,D15 Click Connector(A8)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A8;pinno=26 Click Connector(D15)Instrument Panel>Instrument Panel Wire>EV Control ECUewd_type=component;type=c;code=D15;pinno=26 |
|||
| A8-26 (IMI) - Body ground*1
D15-26 (IMI) - Body ground*2 |
Within 3 seconds of hybrid control system start or within 3 seconds of ignition switch turned to ON after cable disconnected and reconnected to auxiliary battery | 2 V/DIV., 500 ms./DIV. | Pulse generation
(See waveform) |
The waveform is similar to that shown in the illustration.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Register the ECU communication ID codes.
Refer to Service Bulletin.
| Proceed to |
|---|
| NEXT |
NEXT
Check that the hybrid control system starts.
| Result | Proceed to |
|---|---|
| Hybrid control system was started | A |
| Hybrid control system was not started | B |
A
B
Pre-procedure1
Disconnect the A8*1 or D15*2 EV control ECU connector.
*1: for LHD
*2: for RHD
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
*1: for LHD *2: for RHD |
||
|
Click Location & Routing(A8,D15)Location & Routingewd_type=routing;type=c,c;code=A8,D15 Click Connector(A8)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A8;pinno=29 Click Connector(D15)Instrument Panel>Instrument Panel Wire>EV Control ECUewd_type=component;type=c;code=D15;pinno=29 |
||
| A8-29 (IMO) - Body ground*1 | Ignition switch turned to ON using registered electrical key transmitter sub-assembly | Terminal IMO stuck low (2.4 V or less) |
| D15-29 (IMO) - Body ground*2 | Ignition switch turned to ON using registered electrical key transmitter sub-assembly | Terminal IMO stuck low (2.4 V or less) |
| A8-29 (IMO) - Body ground*1 | Ignition switch turned to ON using registered electrical key transmitter sub-assembly | Terminal IMO stuck high (12 V) or abnormal waveform |
| D15-29 (IMO) - Body ground*2 | Ignition switch turned to ON using registered electrical key transmitter sub-assembly | Terminal IMO stuck high (12 V) or abnormal waveform |
| Result | Proceed to |
|---|---|
| Terminal IMO stuck low (2.4 V or less) | A |
| Terminal IMO stuck high (12 V) or abnormal waveform | B |
Post-procedure1
None.
A
B
Pre-procedure1
Disconnect the D73 ID code box (immobiliser code ECU) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
*1: for LHD *2: for RHD |
||
|
Click Location & Routing(D73,A8,D15)Location & Routingewd_type=routing;type=c,c,c;code=D73,A8,D15 Click Connector(D73)Instrument Panel>Instrument Panel Wire>ID Code Box (Immobiliser Code ECU)ewd_type=component;type=c;code=D73;pinno=3,4 Click Connector(A8)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A8;pinno=29,26 Click Connector(D15)Instrument Panel>Instrument Panel Wire>EV Control ECUewd_type=component;type=c;code=D15;pinno=29,26 |
||
| D73-3 (EFII) - A8-29 (IMO)*1 | Always | Below 1 Ω |
| D73-3 (EFII) - D15-29 (IMO)*2 | Always | Below 1 Ω |
| D73-3 (EFII) or A8-29 (IMO) - Other terminals and body ground*1 | Always | 10 kΩ or higher |
| D73-3 (EFII) or D15-29 (IMO) - Other terminals and body ground*2 | Always | 10 kΩ or higher |
| D73-4 (EFIO) - A8-26 (IMI)*1 | Always | Below 1 Ω |
| D73-4 (EFIO) - D15-26 (IMI)*2 | Always | Below 1 Ω |
| D73-4 (EFIO) or A8-26 (IMI) - Other terminals and body ground*1 | Always | 10 kΩ or higher |
| D73-4 (EFIO) or D15-26 (IMI) - Other terminals and body ground*2 | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
Disconnect the D73 ID code box (immobiliser code ECU) connector.
Disconnect the A8*1 or D15*2 EV control ECU connector.
*1: for LHD
*2: for RHD
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
*1: for LHD *2: for RHD |
||
|
Click Location & Routing(D73,A8,D15)Location & Routingewd_type=routing;type=c,c,c;code=D73,A8,D15 Click Connector(D73)Instrument Panel>Instrument Panel Wire>ID Code Box (Immobiliser Code ECU)ewd_type=component;type=c;code=D73;pinno=3 Click Connector(A8)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A8;pinno=29 Click Connector(D15)Instrument Panel>Instrument Panel Wire>EV Control ECUewd_type=component;type=c;code=D15;pinno=29 |
||
| D73-3 (EFII) - A8-29 (IMO)*1 | Always | Below 1 Ω |
| D73-3 (EFII) - D15-29 (IMO)*2 | Always | Below 1 Ω |
| D73-3 (EFII) or A8-29 (IMO) - Other terminals and body ground*1 | Always | 10 kΩ or higher |
| D73-3 (EFII) or D15-29 (IMO) - Other terminals and body ground*2 | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG