The cooler thermistor (room temperature sensor) is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the cooler thermistor (room temperature sensor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the cooler thermistor (room temperature sensor) and reads voltage changes due to changes in the resistance of the cooler thermistor (room temperature sensor).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| B1411 | Room Temperature Sensor Circuit | ·
Cooler thermistor (room temperature sensor) ·
Harness or connector ·
Air conditioning amplifier assembly |
Memorized | Air Conditioner | A |
If the cabin temperature is approximately -18.6°C (-1.48°F) or lower, DTC B1411 may be output even though the system is normal.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler (room temperature sensor) thermistor | Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | Cooler thermistor system malfunction
·
When open circuit: -6.50°C (20.30°F) ·
When short circuit: 57.25°C (135.05°F) |
| Tester Display |
|---|
| Room Temperature Sensor |
The display is as specified in the normal condition column.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the D80 air conditioning amplifier assembly connector.
Disconnect the D45 cooler thermistor (room temperature sensor) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D80,D45)Location & Routingewd_type=routing;type=c,c;code=D80,D45 Click Connector(D80)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=D80;pinno=14,1 Click Connector(D45)Instrument Panel>Instrument Panel Wire>Cooler (Room Temperature Sensor) Thermistorewd_type=component;type=c;code=D45;pinno=1,2 |
||
| D80-14 (TR) - D45-1 | Always | Below 1 Ω |
| D80-1 (SG-1) - D45-2 | Always | Below 1 Ω |
| D80-14 (TR) or D45-1 - Other terminals and body ground | Always | 10 kΩ or higher |
| D80-1 (SG-1) or D45-2 - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG