These DTCs are stored when communication between the radio and display receiver assembly and combination meter assembly or meter mirror sub-assembly* is not possible.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Priority |
|---|---|---|---|---|---|
| B1324 | Lost Communication with Meter | CAN reception error | ·
Local bus communication line ·
Combination meter power source circuit ·
Combination meter assembly ·
Radio and display receiver assembly ·
Harness or connector ·
No. 2 junction connector |
Navigation System | A |
| B1325 | Lost Communication with HUD | CAN reception error | ·
Local bus communication line ·
Meter mirror sub-assembly power source circuit ·
Meter mirror sub-assembly ·
Radio and display receiver assembly ·
Harness or connector ·
No. 2 junction connector |
Navigation System | A |
*: w/ Headup Display
The radio and display receiver assembly is the master unit.
When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.
Inspect the fuses for circuits related to this system before performing the following procedure.
B1324 and B1325 will not continue to output when clear DTC is performed even if the malfunction continues.
Check for DTCs and check that no DTCs are output.
| Result | Proceed to |
|---|---|
| B1324 and B1325 are not output | A |
| B1324 and B1325 are output | B |
| Only B1324 is output | C |
| Only B1325 is output | D |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
C
D
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D167)Location & Routingewd_type=routing;type=c;code=D167 Click Connector(D167)Instrument Panel>Instrument Panel Wire>No. 2 CAN Junction Connectorewd_type=component;type=c;code=D167;pinno=13,2 |
||
| D167-13 - D167-2 | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Result | Proceed to |
|---|---|
| D167-13 - D167-2 is less than or equal to 54 Ω | A |
| D167-13 - D167-2 is more than or equal to 70 Ω | B |
| None of the above conditions are met | C |
Post-procedure1
None
A
B
C
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D167 No. 2 junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D167)Location & Routingewd_type=routing;type=c;code=D167 Click Connector(D167)Instrument Panel>Instrument Panel Wire>No. 2 CAN Junction Connectorewd_type=component;type=c;code=D167;pinno=13,2 |
||
| D167-13 - D167-2 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D167 No. 2 junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D167)Location & Routingewd_type=routing;type=c;code=D167 Click Connector(D167)Instrument Panel>Instrument Panel Wire>No. 2 CAN Junction Connectorewd_type=component;type=c;code=D167;pinno=14,3 |
||
| D167-14 - D167-3 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D167 No. 2 junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D167)Location & Routingewd_type=routing;type=c;code=D167 Click Connector(D167)Instrument Panel>Instrument Panel Wire>No. 2 CAN Junction Connectorewd_type=component;type=c;code=D167;pinno=14,3 |
||
| D167-14 - D167-3 | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D95 meter mirror sub-assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D95)Location & Routingewd_type=routing;type=c;code=D95 Click Connector(D95)Instrument Panel>Instrument Panel Wire>Meter Mirror Sub-Assemblyewd_type=component;type=c;code=D95;pinno=14,15 |
||
| D95-14 (TX+) - D95-15 (TX-) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D41 combination meter assembly connector.
Connect the D167 No. 2 junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D41)Location & Routingewd_type=routing;type=c;code=D41 Click Connector(D41)Instrument Panel>Instrument Panel Wire>Combination Meter Assemblyewd_type=component;type=c;code=D41;pinno=8,7 |
||
| D41-8 (TX+) - D41-7 (TX-) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D56 radio and display receiver assembly connector.
Connect the D167 No. 2 junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D56)Location & Routingewd_type=routing;type=c;code=D56 Click Connector(D56)Instrument Panel>Instrument Panel Wire>Radio Receiver Assemblyewd_type=component;type=c;code=D56;pinno=5,6 |
||
| D56-5 (CNH1) - D56-6 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D56 radio and display receiver assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D56)Location & Routingewd_type=routing;type=c;code=D56 Click Connector(D56)Instrument Panel>Instrument Panel Wire>Radio Receiver Assemblyewd_type=component;type=c;code=D56;pinno=5,6 |
||
| D56-5 (CNH1) - D56-6 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D167 No. 2 junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D167)Location & Routingewd_type=routing;type=c;code=D167 Click Connector(D167)Instrument Panel>Instrument Panel Wire>No. 2 CAN Junction Connectorewd_type=component;type=c;code=D167;pinno=13,2 |
||
| D167-13 - D167-2 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the D41 combination meter assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D41)Location & Routingewd_type=routing;type=c;code=D41 Click Connector(D41)Instrument Panel>Instrument Panel Wire>Combination Meter Assemblyewd_type=component;type=c;code=D41;pinno=31 |
||
| D41-31 (ES) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D41)Location & Routingewd_type=routing;type=c;code=D41 Click Connector(D41)Instrument Panel>Instrument Panel Wire>Combination Meter Assemblyewd_type=component;type=c;code=D41;pinno=22,21 |
||
| D41-22 (B) - Body ground | Ignition switch off | 11 to 14 V |
| D41-21 (IG+) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D167 No. 2 junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D167)Location & Routingewd_type=routing;type=c;code=D167 Click Connector(D167)Instrument Panel>Instrument Panel Wire>No. 2 CAN Junction Connectorewd_type=component;type=c;code=D167;pinno=14,3 |
||
| D167-14 - D167-3 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D41 combination meter assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D41)Location & Routingewd_type=routing;type=c;code=D41 Click Connector(D41)Instrument Panel>Instrument Panel Wire>Combination Meter Assemblyewd_type=component;type=c;code=D41;pinno=8,7 |
||
| D41-8 (TX+) - D41-7 (TX-) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the D95 meter mirror sub-assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D95)Location & Routingewd_type=routing;type=c;code=D95 Click Connector(D95)Instrument Panel>Instrument Panel Wire>Meter Mirror Sub-Assemblyewd_type=component;type=c;code=D95;pinno=4 |
||
| D95-4 (ES) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D95)Location & Routingewd_type=routing;type=c;code=D95 Click Connector(D95)Instrument Panel>Instrument Panel Wire>Meter Mirror Sub-Assemblyewd_type=component;type=c;code=D95;pinno=2,1 |
||
| D95-2 (B) - Body ground | Ignition switch off | 11 to 14 V |
| D95-1 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D167 No. 2 junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D167)Location & Routingewd_type=routing;type=c;code=D167 Click Connector(D167)Instrument Panel>Instrument Panel Wire>No. 2 CAN Junction Connectorewd_type=component;type=c;code=D167;pinno=12,1 |
||
| D167-12 - D167-1 | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D167 No. 2 junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D167)Location & Routingewd_type=routing;type=c;code=D167 Click Connector(D167)Instrument Panel>Instrument Panel Wire>No. 2 CAN Junction Connectorewd_type=component;type=c;code=D167;pinno=13,2 |
||
| D167-13 - D167-2 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D56 radio and display receiver assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D56)Location & Routingewd_type=routing;type=c;code=D56 Click Connector(D56)Instrument Panel>Instrument Panel Wire>Radio Receiver Assemblyewd_type=component;type=c;code=D56;pinno=5,6 |
||
| D56-5 (CNH1) - D56-6 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D95 meter mirror sub-assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D95)Location & Routingewd_type=routing;type=c;code=D95 Click Connector(D95)Instrument Panel>Instrument Panel Wire>Meter Mirror Sub-Assemblyewd_type=component;type=c;code=D95;pinno=14,15 |
||
| D95-14 (TX+) - D95-15 (TX-) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG