Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2020.11–2021.08
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0463852 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P1CB59E  DC/DC Converter "A" Overvoltage Signal Stuck On  


DTC SUMMARY

MALFUNCTION DESCRIPTION


These DTCs indicate a malfunction inside the inverter for the motor. The cause of this malfunction may be one of the following:

Internal inverter malfunction
·

Internal circuit malfunction in the inverter for the motor

·

Malfunction in the sensors for inverter control (current sensor, voltage sensors (VH, VL), etc.)



DESCRIPTION

For a description of the boost converter.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0CA300

If a malfunction occurs in the boost converter, the MG ECU detects it and transmits this information to the EV control ECU.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1CB59E DC/DC Converter "A" Overvoltage Signal Stuck On Boost converter overvoltage signal detected (circuit malfunction):
Overvoltage or a circuit malfunction is detected before boosting.
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Master Warning:
Comes on
EV A

Related Data List
DTC No. Data List
P1CB59E VL-Voltage before Boosting

CONFIRMATION DRIVING PATTERN

HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


1.

Enter the following menus: Powertrain / EV / Data List / FC Work Mode, FC Intermittent Operation.

2.

Push the P position switch (shift position indicator) to select park (P), turn the ignition switch to ON (READY) and wait until the FC system is started. Waiting for at least 2 minutes is required after turning the ignition switch to ON (READY).

-

FC system is started: "Working" is displayed for the Data List item "FC Work Mode" and "FC Intermittent Operation" is OFF.


3.

With the FC system operating, wait for 15 seconds or more.

4.

Enter the following menus: Powertrain / EV / Utility / All Readiness.

5.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grips from both FC stack assembly and EV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the EV supply battery assembly

-

Disconnecting the low voltage connector of the FC converter assembly


·
A484004

To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.

-

The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.

-

Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.


·
A484005C01
1.667,0.74 2.115,0.427 true 2.188,0.385 2.448,0.552 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.

If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.



NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART


·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



PROCEDURE

1.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A001C

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

REPLACE INVERTER WITH CONVERTER ASSEMBLY

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR