The cause of this malfunction may be the FC air compressor motor resolver.
Check the FC air compressor motor resolver internal resistance and connection condition from the inverter to the resolver.
| Area | Inspection |
|---|---|
| Wire harness and connector between the inverter and FC air compressor motor resolver | Check for short circuit between wire harness and +B side. |
| Resolver, wire harness, connector | Check the internal resistance of resolver (including wire harness), body ground resistance, and connector connection condition. |
| Wire harness, connector | Check for open or short circuit of the wire harness |
A resolver is a sensor that is used to detect the position of the magnetic poles of the rotor of a FC air compressor motor. Knowing the position of the poles is indispensable for ensuring precise control of the FC air compressor motor.
Each resolver contains a stator that has an excitation coil and 2 detection coils (S, C). The gap between the stator and rotor changes as the rotor turns because the rotor is oval shaped. An alternating current with a predetermined frequency flows through the excitation coil, and detection coils S and C output alternating currents in accordance with the sensor rotor position.
The MG ECU, which is built into the inverter with converter assembly, detects the absolute position of the rotor according to the phases of detection coils S and C and the heights of their waveforms. Furthermore, the CPU calculates the amount of change in the position within a predetermined length of time, in order to use the resolver as a revolution speed sensor.
The MG ECU monitors signals output from the FC air compressor motor resolver and detects malfunctions.
This step is referenced from the procedures for each DTC.
If the inspection results below are normal, perform the next procedure for the referenced DTC.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
If the problem symptom cannot be reproduced, performing a road test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.
If the resolver is malfunctioning, the vehicle may not drive smoothly.
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Procedure1
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-20 (GRF) - Body ground | Ignition switch ON | Below 1 V |
| A19-9 (GRFG) - Body ground | Ignition switch ON | Below 1 V |
| A19-18 (GSN) - Body ground | Ignition switch ON | Below 1 V |
| A19-7 (GSNG) - Body ground | Ignition switch ON | Below 1 V |
| A19-17 (GCS) - Body ground | Ignition switch ON | Below 1 V |
| A19-6 (GCSG) - Body ground | Ignition switch ON | Below 1 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-20 (GRF) - Body ground | Ignition switch ON | Below 1 V |
| A18-9 (GRFG) - Body ground | Ignition switch ON | Below 1 V |
| A18-18 (GSN) - Body ground | Ignition switch ON | Below 1 V |
| A18-7 (GSNG) - Body ground | Ignition switch ON | Below 1 V |
| A18-17 (GCS) - Body ground | Ignition switch ON | Below 1 V |
| A18-6 (GCSG) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Procedure1
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-20 (GRF) - A19-9 (GRFG) | Ignition switch off | 6.5 to 21.5 Ω |
| A19-18 (GSN) - A19-7 (GSNG) | Ignition switch off | 10.0 to 37.5 Ω |
| A19-17 (GCS) - A19-6 (GCSG) | Ignition switch off | 9.0 to 35.5 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-20 (GRF) - A18-9 (GRFG) | Ignition switch off | 6.5 to 21.5 Ω |
| A18-18 (GSN) - A18-7 (GSNG) | Ignition switch off | 10.0 to 37.5 Ω |
| A18-17 (GCS) - A18-6 (GCSG) | Ignition switch off | 9.0 to 35.5 Ω |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68°F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C (°F).)
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-20 (GRF) or A19-9 (GRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-18 (GSN) or A19-7 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-17 (GCS) or A19-6 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-20 (GRF) or A18-9 (GRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-18 (GSN) or A18-7 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-17 (GCS) or A18-6 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Procedure1
Check the connection condition of the FC air compressor motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
Post-procedure1
None.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Disconnect the B24 FC air compressor motor resolver connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *a | Front view of wire harness connector
(FC Air Compressor Motor Resolver) |
*b | Front view of wire harness connector
(Inverter with Converter Assembly) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19,B24)Location & Routingewd_type=routing;type=c,c;code=A19,B24 Click Connector(B24)Engine Compartment>No. 2 Stack Wire>FC Air Compressor with Motor Assemblyewd_type=component;type=c;code=B24;pinno=1,5,2,6,3,7 |
||
| A19-20 (GRF) - B24-1 (GRF) | Ignition switch off | Below 1 Ω |
| A19-9 (GRFG) - B24-5 (GRFG) | Ignition switch off | Below 1 Ω |
| A19-18 (GSN) - B24-2 (GSN) | Ignition switch off | Below 1 Ω |
| A19-7 (GSNG) - B24-6 (GSNG) | Ignition switch off | Below 1 Ω |
| A19-17 (GCS) - B24-3 (GCS) | Ignition switch off | Below 1 Ω |
| A19-6 (GCSG) - B24-7 (GCSG) | Ignition switch off | Below 1 Ω |
| A19-20 (GRF) or B24-1 (GRF) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-9 (CRFG) or B24-5 (CRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-18 (GSN) or B24-2 (GSN) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-7 (GSNG) or B24-6 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-17 (GCS) or B24-3 (GCS) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-6 (GCSG) or B24-7 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18,B24)Location & Routingewd_type=routing;type=c,c;code=A18,B24 Click Connector(B24)Engine Compartment>No. 2 Stack Wire>FC Air Compressor with Motor Assemblyewd_type=component;type=c;code=B24;pinno=1,5,2,6,3,7 |
||
| A18-20 (GRF) - B24-1 (GRF) | Ignition switch off | Below 1 Ω |
| A18-9 (GRFG) - B24-5 (GRFG) | Ignition switch off | Below 1 Ω |
| A18-18 (GSN) - B24-2 (GSN) | Ignition switch off | Below 1 Ω |
| A18-7 (GSNG) - B24-6 (GSNG) | Ignition switch off | Below 1 Ω |
| A18-17 (GCS) - B24-3 (GCS) | Ignition switch off | Below 1 Ω |
| A18-6 (GCSG) - B24-7 (GCSG) | Ignition switch off | Below 1 Ω |
| A18-20 (GRF) or B24-1 (GRF) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-9 (CRFG) or B24-5 (CRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-18 (GSN) or B24-2 (GSN) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-7 (GSNG) or B24-6 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-17 (GCS) or B24-3 (GCS) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-6 (GCSG) or B24-7 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
The FC air compressor motor resolver is not available as a supply part. If it requires replacement, replace the FC air compressor with motor assembly.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the B24 FC air compressor motor resolver connector.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG