FC CONTROL  HYDROGEN DETECTOR(for Motor Room Side)  REMOVAL  


CAUTION / NOTICE / HINT

COMPONENTS (REMOVAL)
A484099N01
4.51,2.854 5.115,2.854 true 4.594,2.042 5.198,2.042 true 6.177,0.323 6.781,0.323 true 5.25,1.948 5.583,2.188 0.333,0.24 10 false *1 4.333,3.177 4.667,3.417 0.333,0.24 10 false x 2 5.531,2.729 5.906,3.063 0.375,0.333 18 false 2 5.979,0.198 6.354,0.531 0.375,0.333 18 false 1

Procedure Part Name Code
Z101186

Z101188

Z101187

1 PRECAUTION - (Click here) - -
2 HYDROGEN DETECTOR G4151 (Click here) - -

*1 NO. 1 HYDROGEN DETECTOR BRACKET - -

PROCEDURE

Hide 1. PRECAUTION

Z101186

NOTICE:
A340923E01
0.813,0.458 1.385,0.781 true 1.917,0.365 1.677,0.698 true 0.646,0.354 0.958,0.552 0.313,0.198 10 false *a 1.938,0.219 2.25,0.417 0.313,0.198 10 false *b

·

If the hydrogen detector is dropped or subjected to a strong impact, replace it with a new one.

·

Because water resistance will be degraded and error will be introduced to detection precision, do not poke the water resistant membrane (*b) of the hydrogen detecting portion (*a) with sharp objects.

·

Because water resistance will be degraded and error will be introduced to detection precision, do not directly spray the water resistant membrane (*b) of the hydrogen detecting portion (*a) with high pressure water or air.

·

Because water resistance will be degraded and error will be introduced to detection precision, do not expose the water resistant membrane (*b) of the hydrogen detector to an environment that is 120°C or higher.

·

Because error will be introduced to detection precision, do not expose the hydrogen detector to environments with high gas or solvent concentration of 4% or more.

·

Because error will be introduced to detection precision, do not directly spray the hydrogen detecting portion (*a) with sprays such as preservatives, polishing agents, silicone, or those containing combustible gases such as isobutane, etc.




Hide G4151 2.REMOVE HYDROGEN DETECTOR

Z101186

NOTICE:

If the hydrogen detector is dropped or subjected to a strong impact, replace it with a new one.