If the hydrogen detector is dropped or subjected to a strong impact, replace it with a new one.
·
Because water resistance will be degraded and error will be introduced to detection precision, do not poke the water resistant membrane (*b) of the hydrogen detecting portion (*a) with sharp objects.
·
Because water resistance will be degraded and error will be introduced to detection precision, do not directly spray the water resistant membrane (*b) of the hydrogen detecting portion (*a) with high pressure water or air.
·
Because water resistance will be degraded and error will be introduced to detection precision, do not expose the water resistant membrane (*b) of the hydrogen detector to an environment that is 120°C or higher.
·
Because error will be introduced to detection precision, do not expose the hydrogen detector to environments with high gas or solvent concentration of 4% or more.
·
Because error will be introduced to detection precision, do not directly spray the hydrogen detecting portion (*a) with sprays such as preservatives, polishing agents, silicone, or those containing combustible gases such as isobutane, etc.
G41512.REMOVE HYDROGEN DETECTOR
NOTICE:
If the hydrogen detector is dropped or subjected to a strong impact, replace it with a new one.