| Procedure | Part Name Code |
|
|
|
|
|---|---|---|---|---|---|
| 1 | NO. 1 ROOF DRIP SIDE FINISH MOULDING CLIP | 75561 | ( )
|
- | - |
| 2 | CENTER ROOF DRIP SIDE FINISH MOULDING LH | 75556C | - | - | - |
| *A | for Panoramic Moon Roof | *B | for Normal Roof |
| ● | Non-reusable part | - | - |
Use the same procedure for the RH and LH sides.
The procedure described below is for the LH side.
75561
1.INSTALL NO. 1 ROOF DRIP SIDE FINISH MOULDING CLIP
|
|
| *A | for Panoramic Moon Roof | *B | for Normal Roof |
| *a | Adhesive | *b | 2 to 3 mm (0.0787 to 0.1181 in.)Bead of Adhesive |
| Area | Measurement | Area | Measurement |
|---|---|---|---|
| A | 2.4 mm (0.0945 in.) | B | 1.1 mm (0.0433 in.) |
| C | 4.1 mm (0.161 in.) | D | 1.3 mm (0.0512 in.) |
| E | 4.1 mm (0.161 in.) | F | 1.5 mm (0.0591 in.) |
Clean the vehicle body surface.
1. Using a heat light, heat the vehicle body surface.
| Part | Temperature |
|---|---|
| Vehicle Body | 40 to 60°C (104 to 140°F) |
| *a | Heated Part |
| *b | Heat Light |
Do not touch the heat light and heated parts.
Touching the heat light may result in burns.
Touching heated parts for a long time may result in burns.
Do not heat the vehicle body excessively.
2. Remove the double-sided tape from the vehicle body.
3. Wipe off any tape adhesive residue with cleaner.
Installing the No. 1 roof drip side finish moulding clip with some double-sided tape remaining may cause poor adhesion. Perform this procedure until the tape is sufficiently removed.
Make sure to use a cloth when removing. Using a screwdriver, etc., may cause damage and poor adhesion.
Apply a 2 to 3 mm (0.0787 to 0.118 in.) bead of adhesive (3M DP-105 or equivalent) to each new No. 1 roof drip side finish moulding clip.
Adhesive strength (tensile strength): 13.7 MPa (140.0 kgf/cm2, 1987 psi) or more (when the temperature is 23°C (73°F).)
Apply primer to the body where the No. 1 roof drip side finish moulding clip will be installed.
Do not let the primer dry.
While using the position shown in the illustration as a reference, place the No. 1 roof drip side finish moulding clip onto the roof panel. Then position and install the clip using the locations on the roof panel after lightly pressing it so that the adhesive adheres to the primer.
Install the center roof drip side finish moulding LH when 40 minutes or more have elapsed after pressing and installing the No. 1 roof drip side finish moulding clips.
Initial hardening time: 40 minutes
Complete hardening time: 24 hours
75556C
2.INSTALL CENTER ROOF DRIP SIDE FINISH MOULDING LH