The air conditioning amplifier assembly uses the target blower temperature to calculate the target water temperature, and selects the electric heater sub-assembly drive level based on the water temperature sensor value.
The air conditioning amplifier assembly sends the drive level to the EV control ECU via the CAN communication system, and the EV control ECU drives the electric heater sub-assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1F09 | Open in High Voltage Electric Heater STB Circuit | The air conditioning amplifier assembly stores this DTC if it detects a malfunction in the electric heater sub-assembly.
Diagnosis condition:
When electric heater sub-assembly is driven Malfunction status:
Electric heater sub-assembly drive signal is short Detection time:
Electric heater sub-assembly drive line is short |
·
Hybrid control system ·
Harness or connector ·
EV control ECU ·
Electric heater sub-assembly |
Memorized | Air Conditioner | B |
After removing the EV battery service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
After removing the EV battery service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Inspect the fuses for circuits related to this system before performing the following procedure.
After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
The hybrid control system and air conditioning system output DTCs separately. Perform troubleshooting for the hybrid control system first if DTCs from these systems are output simultaneously.
Pre-procedure1
Disconnect the B2 electric heater sub-assembly connector.
Disconnect the A17 EV control ECU connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B2,A17)Location & Routingewd_type=routing;type=c,c;code=B2,A17 Click Connector(B2)Engine Compartment>No. 2 Stack Wire>Electric Heater Sub-Assemblyewd_type=component;type=c;code=B2;pinno=5 Click Connector(A17)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A17;pinno=19 |
||
| B2-5 (STB) - A17-19 (STB) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG