If cool air is not discharged (air is discharged), the following malfunctions are possible.
| Symptom | Factor |
|---|---|
| No cooling at all (air is discharged) | ·
Compressor with motor assembly malfunction ·
Refrigerant pressure malfunction ·
Quantity of refrigerant gas lack ·
Dirty cooler condenser ·
Cooling fan system malfunction ·
A/M damper servo malfunction ·
Damper and link operation (jamming) ·
No. 1 cooler thermistor malfunction (determined as cold, conflicting with actual temperature) ·
Warm air flow |
Operate each switch on the air conditioning control assembly to check that the switch indicators are illuminated normally.
Switch indicator is illuminated normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Restrict Condition |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation |
Min.: 128
Max.: 383 |
for LHD (for Dual):
Operates between 154 to 258 pulses for LHD (for 3 Zone):
Operates between 254 to 358 pulses for RHD:
Operates between 154 to 258 pulses |
| Air Mix Servo Targ Pulse(P) | for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation |
Min.: 128
Max.: 383 |
for LHD:
Operates between 154 to 258 pulses for RHD (for Dual):
Operates between 154 to 258 pulses for RHD (for 3 Zone):
Operates between 254 to 358 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
Damper servo motor is operated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>DIAGNOSTIC TROUBLE CODE CHART