If warm air is not discharged (airflow volume control is normal), the following malfunctions are possible.
| Symptom | Factor |
|---|---|
·
No heating at all (airflow volume control is normal) ·
Air outlet temperature does not increase (airflow volume control is normal) |
·
Low FC stack outlet coolant temperature ·
A/M damper servo malfunction ·
Damper and link operation (jamming) ·
Warm-up control ·
Heater core closed waterway ·
Water with motor pump assembly malfunction ·
Electric hetar circuit malfunction |
Check for DTCs.
DTC is not output.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| FC Stack Outlet Coolant Temperature (Filtered Value) | FC stack outlet coolant temperature | -40°C (-40°F) to 215.9 °C (421 °F) | 50 to 85 °C (122 to 185 °F): After warming up | - |
| Tester Display |
|---|
| FC Stack Outlet Coolant Temperature (Filtered Value) |
The value of the display does not change frequently.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Restrict Condition |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation |
Min.: 128
Max.: 383 |
for LHD (for Dual):
Operates between 154 to 258 pulses for LHD (for 3 Zone):
Operates between 254 to 358 pulses for RHD:
Operates between 154 to 258 pulses |
| Air Mix Servo Targ Pulse(P) | for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation |
Min.: 128
Max.: 383 |
for LHD:
Operates between 154 to 258 pulses for RHD (for Dual):
Operates between 154 to 258 pulses for RHD (for 3 Zone):
Operates between 254 to 358 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
Damper servo motor is operated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Restrict Condition |
|---|---|---|---|
| Heater Active Level | Quick heater assembly | Min.: 0
Max.: 2 |
Perform this test when the following conditions are met:
·
Ignition switch ON (READY) ·
Air conditioning system is operated |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Electric Heater Active Level | Maximum electric heater operation level | Min.: 0
Max.: 2 |
Maximum possible operation level of electric heater displayed | - |
| Active Test Display |
|---|
| Heater Active Level |
| Data List Display |
|---|
| Electric Heater Active Level |
Inspect the heater accessory assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG