DESCRIPTION

If the front glass frequently fogs up when the air conditioning system is operated, the following causes are possible.

Symptom Factor
Front glass fogs up

(Does not cool)


·

Compressor with motor assembly malfunction

·

Quantity of refrigerant gas lack

·

Cooler expansion valve malfunction (opened too far)

·

DEF servo motor malfunction

·

Damper and link operation (jamming)



PROCEDURE

1.CHECK REFRIGERANT SHORTAGE
a.

Prepare the vehicle according to the table below.

Measurement Condition:
Item Condition
A/C switch On
Ambient temperature*1 0 to 49°C (32 to 120°F)
Air conditioning inlet temperature*2 25 to 49°C (77 to 120°F)
Setting temperature MAX COLD
Blower damper position Recirculation
Outlet damper position FACE
Blower speed HI

*1: If the ambient temperature is not within the range shown, do not perform this check.

*2: The air inlet temperature can be judged correctly only if it is within an appropriate range of 25 to 79°C (77 to 174°F). Therefore, use the heater mode to adjust the temperature so that it falls within the appropriate range and then perform the check.



b.

Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 121 3186
Result:
Result Amount of Refrigerant
Refrigerant shortage Insufficient or leakage
Refrigerant correct Correct



Result:
Result Proceed to
Insufficient or leakage A
Correct B



A

2.CHECK OPERATION

B

2.CHECK OPERATION
a.

When the MODE switch pushed, check that the air conditioning system changes DEF mode according to the switch operation.

OK:

Air conditioning system changes DEF mode.



Result:
Proceed to
OK
NG



OK

GO TO ON-VEHICLE INSPECTION (CHECK REFRIGERANT PRESSURE USING GAUGE)

NG