Air that flows into the FC stack is compressed by the FC air compressor with motor assembly, and then cooled down by the intercooler. The FC stack inlet air pressure sensor (vacuum sensor assembly) monitors pressure of the air, and converts it into a voltage.
The FC stack inlet air pressure sensor (vacuum sensor assembly) measures pressure of the air flowing into the FC stack as absolute pressure, thus, it can measure the FC stack inlet air pressure without influence from changes in the atmospheric pressure due to altitude, etc.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1D9011 | FC Stack Inlet Pressure Sensor Circuit Short to Ground | If the +B voltage is not low when the ignition switch is turned to ON, the output voltage of the FC stack inlet air pressure sensor (vacuum sensor assembly) circuit remains at less than 0.60 V for more than 3 seconds.
(1 trip detection logic) |
·
FC stack inlet air pressure sensor (vacuum sensor assembly) ·
EV control ECU ·
Wire harness or connector |
Master Warning: Comes on | EV | A |
| P1D9015 | FC Stack Inlet Pressure Sensor Circuit Short to Battery or Open | If the +B voltage is not low when the ignition switch is turned to ON, the output voltage of the FC stack inlet air pressure sensor (vacuum sensor assembly) circuit remains at more than 4.85 V for more than 3 seconds.
(1 trip detection logic) |
·
FC stack inlet air pressure sensor (vacuum sensor assembly) ·
EV control ECU ·
Wire harness or connector |
Master Warning: Comes on | EV | A |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | ○ | ○ | ○ | ○ | ○ | - |
By accessing the "FC Work Mode" and "FC Intermittent Operation" in the freeze frame data, the FC system condition at the time the malfunction occurred can be checked.
| DTC No. | Data List |
|---|---|
| P1D9011 | FC Inter Cooler Outlet Pressure Sensor Voltage |
| P1D9015 |
If DTCs are found, read the "FC Inter Cooler Outlet Pressure Sensor Voltage" in the Data List on a GTS.
| FC Inter Cooler Outlet Pressure Sensor Voltage | Malfunction |
|---|---|
| Less than 0.60 V | ·
Open in VICP (5 V power supply) circuit ·
Short in ICP circuit to ground ·
Short in ICP circuit to GIC2 (GND) circuit |
| Higher than 4.85 V | ·
Short in VICP circuit to ICP circuit ·
Open in ICP circuit ·
Open in GIC2 (GND) circuit |
It is suspected that malfunctions, or open/short circuits have occurred in the FC stack inlet air pressure sensor (vacuum sensor assembly).
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON and wait for 5 seconds or more.
Pre-procedure1
Disconnect the FC stack inlet air pressure sensor (vacuum sensor assembly) connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B13)Location & Routingewd_type=routing;type=c;code=B13 Click Connector(B13)Engine Compartment>No. 2 Stack Wire>Vacuum Sensor Assemblyewd_type=component;type=c;code=B13;pinno=3,2,1 |
||
| B13-3 (VC) - B13-2 (E2) | Ignition switch ON | 4.75 to 5.25 V |
| B13-1 (PIM) - B13-2 (E2) | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the FC stack inlet air pressure sensor (vacuum sensor assembly) connector.
OK
NG
NEXT
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Pre-procedure1
Turn the ignition switch to ON and wait for 5 seconds or more.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1D9011 or P1D9015 is output | A |
| DTCs are not output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Pre-procedure1
Disconnect the EV control ECU connector.
Disconnect the FC stack inlet air pressure sensor (vacuum sensor assembly) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G14,B13)Location & Routingewd_type=routing;type=c,c;code=G14,B13 Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECUewd_type=component;type=c;code=G14;pinno=23,22,24 Click Connector(B13)Engine Compartment>No. 2 Stack Wire>Vacuum Sensor Assemblyewd_type=component;type=c;code=B13;pinno=1,2,3 |
||
| G14-23 (ICP) - B13-1 (PIM) | Always | Below 1 Ω |
| G14-22 (GIC2) - B13-2 (E2) | Always | Below 1 Ω |
| G14-24 (VICP) - B13-3 (VC) | Always | Below 1 Ω |
| G14-23 (ICP) or B13-1 (PIM) - Body ground and other terminals | Always | 10 kΩ or higher |
| G14-24 (VICP) or B13-3 (VC) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the EV control ECU connector.
Reconnect the FC stack inlet air pressure sensor (vacuum sensor assembly) connector.
OK
NG
Pre-procedure1
Disconnect the EV control ECU connector.
Disconnect the FC stack inlet air pressure sensor (vacuum sensor assembly) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A14,B13)Location & Routingewd_type=routing;type=c,c;code=A14,B13 Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A14;pinno=23,22,24 Click Connector(B13)Engine Compartment>No. 2 Stack Wire>Vacuum Sensor Assemblyewd_type=component;type=c;code=B13;pinno=1,2,3 |
||
| A14-23 (ICP) - B13-1 (PIM) | Always | Below 1 Ω |
| A14-22 (GIC2) - B13-2 (E2) | Always | Below 1 Ω |
| A14-24 (VICP) - B13-3 (VC) | Always | Below 1 Ω |
| A14-23 (ICP) or B13-1 (PIM) - Body ground and other terminals | Always | 10 kΩ or higher |
| A14-24 (VICP) or B13-3 (VC) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the EV control ECU connector.
Reconnect the FC stack inlet air pressure sensor (vacuum sensor assembly) connector.
OK
NG