The air system feeds the FC stack with a necessary amount of oxygen for power generation. The mass air flow meter sub-assembly, which is a part of the air system, has a built-in intake air temperature sensor that measures an ambient temperature for the FC stack.
When an intake air temperature sensor value is compared to another sensor value that is supposed to be equal to the said sensor value, if it has deviated from other values by more than a threshold, it will be interpreted as occurrence of abnormal sensor deviation, and this DTC will be stored.
For the circuit diagram, refer to DTC P1DDF00.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1DDF00
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P009A62 | Intake Air Temperature/Ambient Air Temperature Correlation Signal Compare Failure | While the vehicle is traveling and the air compressor is operating, the intake air temperature sensor value of the mass air flow meter sub-assembly has significantly deviated from the ambient temperature value of the air conditioning amplifier.
(3 times) |
Mass air flow meter sub-assembly | Master Warning: Comes on | EV | A |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | - | - | - | - | ○ | - |
| DTC No. | System | Data List |
|---|---|---|
| P009A62 | EV | Intake Air Temperature (Filtered Value) |
| Air Conditioner | Ambient Temp Sensor |
This DTC will be output even if ambient temperature sensor values of the air conditioning amplifier are abnormal.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Drive the vehicle at a speed of approximately 40 to 60 km/h (25 to 37 mph) for at least 5 minutes (Vehicle does not have to run continuously at the speeds).
Perform this road test only in an appropriate safe location, in accordance with all local laws.
The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.
Pre-procedure1
None
Procedure1
According to the display on the GTS, check for DTCs in the Health Check.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off.
NEXT
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Pre-procedure1
None
Procedure1
Remove the air cleaner cap sub-assembly, and measure the temperature around the mass air flow meter sub-assembly inside the air cleaner case sub-assembly.
Compare the temperature around the mass air flow meter sub-assembly and the "Intake Air Temperature (Filtered Value)" in the Data List.
| Tester Display |
|---|
| Intake Air Temperature (Filtered Value) |
| Result | Proceed to |
|---|---|
| Except the following. | A |
| Difference between the "Intake Air Temperature (Filtered Value)" and the temperature around the mass air flow meter sub-assembly is more than 10°C (18°F). | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None
Procedure1
Measure the temperature around the ambient temperature sensor.
Compare the temperature around the ambient temperature sensor and the Data List item "Ambient Temp Sensor".
| Tester Display |
|---|
| Ambient Temp Sensor |
Ambient temperature sensor output is influenced by sunlight, so if the vehicle had been parked outdoor for a long time, a sensor value will increase.
| Result | Proceed to |
|---|---|
| Except the following. | A |
| Difference between Data List item "Ambient Temp Sensor" and temperature of area around ambient temperature sensor is 10°C (18°F) or more. | B |
Post-procedure1
Turn the ignition switch off.
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B