The No. 1 ion generator sub-assembly operates when both the ion generator switch and the blower switch are on. The air conditioning amplifier assembly sends a drive signal to the No. 1 ion generator sub-assembly. When the No. 1 ion generator sub-assembly receives the drive signal and starts to operate, it outputs an operation condition signal to the air conditioning amplifier assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| B14B9 | Open in Ion Generator Circuit | Diagnosis condition:
Ignition switch ON, blower switch on, ion generator switch on Malfunction status:
Open in No. 1 ion generator sub-assembly circuit Detection time:
Continuously for 12 seconds or more |
·
Harness or connector ·
No. 1 ion generator sub-assembly ·
Air conditioning amplifier assembly |
Memorized | Air Conditioner | A |
Inspect the fuses for circuits related to this system before performing the following procedure.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Ion Generator | No. 1 ion generator sub-assembly operation | OFF or ON | - |
| Tester Display |
|---|
| Ion Generator |
Check the blower switch OFF state.
The No. 1 ion generator sub-assembly operating sound can be heard for 12 seconds or more according to the Active Test.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the D96 No. 1 ion generator sub-assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D96)Location & Routingewd_type=routing;type=c;code=D96 Click Connector(D96)Instrument Panel>Instrument Panel Wire>Ion Generator Sub-Assemblyewd_type=component;type=c;code=D96;pinno=2 |
||
| D96-2 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D96)Location & Routingewd_type=routing;type=c;code=D96 Click Connector(D96)Instrument Panel>Instrument Panel Wire>Ion Generator Sub-Assemblyewd_type=component;type=c;code=D96;pinno=5 |
||
| D96-5 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| D96-5 (IG) - Body ground | Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
Disconnect the D96 No. 1 ion generator sub-assembly connector.
Disconnect the D81 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D96,D81)Location & Routingewd_type=routing;type=c,c;code=D96,D81 Click Connector(D96)Instrument Panel>Instrument Panel Wire>Ion Generator Sub-Assemblyewd_type=component;type=c;code=D96;pinno=3,4 Click Connector(D81)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=D81;pinno=4,24 |
||
| D96-3 (IG+) - D81-4 (NAIN) | Always | Below 1 Ω |
| D96-4 (PCL) - D81-24 (NANO) | Always | Below 1 Ω |
| D96-3 (IG+) or D81-4 (NAIN) - Other terminals and body ground | Always | 10 kΩ or higher |
| D96-4 (PCL) or D81-24 (NANO) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
Disconnect the D81 air conditioning amplifier assembly connector.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D81)Location & Routingewd_type=routing;type=c;code=D81 Click Connector(D81)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=D81;pinno=24 |
||
| D81-24 (NANO) - Body ground | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D81)Location & Routingewd_type=routing;type=c;code=D81 Click Connector(D81)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=D81;pinno=24 |
||
| D81-24 (NANO) - Body ground | ·
Engine switch on (IG) ·
Blower switch: LO ·
Ion generator switch on |
Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the D96 No. 1 ion generator sub-assembly connector.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D96)Location & Routingewd_type=routing;type=c;code=D96 Click Connector(D96)Instrument Panel>Instrument Panel Wire>Ion Generator Sub-Assemblyewd_type=component;type=c;code=D96;pinno=3 |
||
| D96-3 (IG+) - Body ground | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D81)Location & Routingewd_type=routing;type=c;code=D81 Click Connector(D81)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=D81;pinno=4 |
||
| D81-4 (NAIN) - Body ground | ·
Engine switch on (IG) ·
Blower switch off ·
Ion generator switch on |
Below 2.2 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG