DTC B2250 is output if the closer pulse sensor of the multiplex network door ECU has a malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| B2250 | PBD/PTL Closer Operation | When closer pulse sensor of luggage door closer assembly has malfunction | ·
Luggage door closer assembly ·
Multiplex network door ECU ·
Harness or connector |
Not applicable | Back Door | A |
If a multiplex network door ECU DTC is output, the luggage compartment door closer stops operating.
Pre-procedure1
Disconnect the G15 multiplex network door ECU connector.
Disconnect the K2 luggage door closer assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G15,K2)Location & Routingewd_type=routing;type=c,c;code=G15,K2 Click Connector(G15)Body>Floor Wire / No. 3 Floor Wire>Multiplex Network Door ECUewd_type=component;type=c;code=G15;pinno=4,5,9,17 Click Connector(K2)Body>No. 1 Back Door Wire>Luggage Door Closer Assemblyewd_type=component;type=c;code=K2;pinno=3,2,4,9 |
||
| G15-4 (CSV) - K2-3 (CPS+) | Always | Below 1 Ω |
| G15-5 (CS1) - K2-2 (CPS1) | Always | Below 1 Ω |
| G15-9 (CSG) - K2-4 (CPSE) | Always | Below 1 Ω |
| G15-17 (CS2) - K2-9 (CPS2) | Always | Below 1 Ω |
| G15-4 (CSV) or K2-3 (CPS+) - Body ground | Always | 10 kΩ or higher |
| G15-5 (CS1) or K2-2 (CPS1) - Body ground | Always | 10 kΩ or higher |
| G15-9 (CSG) or K2-4 (CPSE) - Body ground | Always | 10 kΩ or higher |
| G15-17 (CS2) or K2-9 (CPS2) - ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the K2 luggage door closer assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(K2)Location & Routingewd_type=routing;type=c;code=K2 Click Connector(K2)Body>No. 1 Back Door Wire>Luggage Door Closer Assemblyewd_type=component;type=c;code=K2;pinno=4 |
||
| K2-4 (CPSE) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(K2)Location & Routingewd_type=routing;type=c;code=K2 Click Connector(K2)Body>No. 1 Back Door Wire>Luggage Door Closer Assemblyewd_type=component;type=c;code=K2;pinno=2,3,9 |
||
| K2-2 (CPS1) - Body ground | Ignition switch ON, luggage compartment door closer not operate | 7 V or higher |
| K2-3 (CPS+) - Body ground | Ignition switch ON, luggage compartment door closer not operate | 7 V or higher |
| K2-9 (CPS2) - Body ground | Ignition switch ON, luggage compartment door closer not operate | 7 V or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the K2 luggage door closer assembly connector.
Disconnect terminals 8 (M+) and 1 (M-) from the luggage door closer assembly connector.
Reconnect the K2 luggage door closer assembly connector.
Procedure1
Using an oscilloscope, check the waveform.
| *a | Component with harness connected
(Luggage Door Closer Assembly) |
*b | Waveform 1 |
| *c | Waveform 2 | - | - |
Do not operate any other functions until this inspection is finished.
| Tester Connection | Condition | Tool Setting | Specified Condition |
|---|---|---|---|
|
Click Location & Routing(K2)Location & Routingewd_type=routing;type=c;code=K2 Click Connector(K2)Body>No. 1 Back Door Wire>Luggage Door Closer Assemblyewd_type=component;type=c;code=K2;pinno=2,9 |
|||
| K2-2 (CPS1) - Body ground | Apply auxiliary battery voltage to the terminals removed from the connector and operate the luggage door closer assembly (closer motor) | 2 V/DIV., 10 ms./DIV. | Pulse generation
(waveform 1) |
| K2-9 (CPS2) - Body ground | Apply auxiliary battery voltage to the terminals removed from the connector and operate the luggage door closer assembly (closer motor) | 2 V/DIV., 10 ms./DIV. | Pulse generation
(waveform 2) |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK