Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › BLIND SPOT MONITOR SYSTEM › from 2021.08
RM37H0E _56 Audio / Visual / Telematics _095293 PARK ASSIST / MONITORING _0455114 BLIND SPOT MONITOR SYSTEM C

PARK ASSIST / MONITORING  BLIND SPOT MONITOR SYSTEM  U0232  Lost Communication with Blind Spot Monitor Slave Module  


DESCRIPTION

This DTC is stored when the blind spot monitor sensor RH judges that there is a communication problem with the blind spot monitor sensor LH.

DTC No. Detection Item DTC Detection Condition Trouble Area DTC Output from Priority
U0232 Lost Communication with Blind Spot Monitor Slave Module The blind spot monitor sensor (master) cannot receive signals from the blind spot monitor sensor (slave)
·

Open or short in CAN bus main wire or connector

·

Open or short in No. 12 global CAN junction connector

·

Blind spot monitor sensor RH

·

Power source circuit of blind spot monitor sensor LH

·

Blind spot monitor sensor LH ground circuit

·

Blind spot monitor sensor LH


Blind Spot Monitor Master B

WIRING DIAGRAM

E334324E81
5.531,2.677 6.854,3.125 1.323,0.448 10 false Blind Spot Monitor Sensor RH 2.25,2.688 3.573,3.135 1.323,0.448 10 false Blind Spot Monitor Sensor LH 3.885,2.667 5.208,3.115 1.323,0.448 10 false No. 12 global CAN Junction Connector 0.052,1.26 0.927,1.813 0.875,0.552 10 false from LUG-IG1 NO.1 Relay 1.458,1.448 2.031,1.99 0.573,0.542 10 false LUG-IG1 NO.2 2.365,1.323 3.24,1.875 0.875,0.552 10 false BLB 2.917,0.99 3.792,1.542 0.875,0.552 10 false CA2P 5.688,0.99 6.563,1.542 0.875,0.552 10 false CA2P 5.688,1.854 6.563,2.406 0.875,0.552 10 false CA2N 2.938,1.854 3.813,2.406 0.875,0.552 10 false CA2N 2.333,1.885 3.208,2.438 0.875,0.552 10 false BLGD 3.896,2.5 4.344,2.719 0.448,0.219 10 false G125 5.531,2.5 5.979,2.719 0.448,0.219 10 false G56 2.25,2.51 2.698,2.729 0.448,0.219 10 false G60 3.833,1.844 4.708,2.396 0.875,0.552 10 false 13 4.885,1.844 5.281,2.094 0.396,0.25 10 false 14 3.906,0.979 4.781,1.531 0.875,0.552 10 false 2 4.906,0.99 5.781,1.542 0.875,0.552 10 false 3 2.156,1.156 3.031,1.708 0.875,0.552 10 false 5 2.083,1.792 2.958,2.344 0.875,0.552 10 false 10 3.385,1.844 4.26,2.396 0.875,0.552 10 false 6 5.49,0.979 6.365,1.531 0.875,0.552 10 false 1 3.375,0.99 4.25,1.542 0.875,0.552 10 false 1 5.49,1.854 6.365,2.406 0.875,0.552 10 false 6

CAUTION / NOTICE / HINT

NOTICE:
·

When checking for DTCs, make sure that the blind spot monitor system is turned on.

·

Inspect the fuses for circuits related to this system before performing the following procedure.

·

Before measuring the resistance of the CAN bus, turn the ignition switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.

·

After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART




HINT:
·

Operating the ignition switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.

·

Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.



PROCEDURE

1.CHECK DTC OUTPUT (PARKING SUPPORT BRAKE SYSTEM)
a.

Using the GTS, check for DTCs according to the prompts on the screen.

Body Electrical > Clearance Warning > Trouble Codes
50001 438

Result:
Result Proceed to
DTCs are not output A
U117787 and U117887 are output B



A

2.CHECK CAN BUS MAIN WIRE

B

GO TO PARKING SUPPORT BRAKE SYSTEM (DTC U117787)

2.CHECK CAN BUS MAIN WIRE

Pre-procedure1

a.

Turn the ignition switch off.


b.

Disconnect the cable from the negative (-) auxiliary battery terminal.


Procedure1

a.
E331798C54
0.135,1.583 0.552,1.854 0.417,0.271 2.01,1.833 2.667,0.917 2.667,0.917 2.833,0.917 true 2.031,2.083 2.615,2.833 2.615,2.833 2.781,2.833 true 0.104,0.135 0.417,0.292 0.313,0.156 10 false *a 0.188,1.646 0.646,1.844 0.458,0.198 10 false G125 2.917,0.844 3.375,1.042 0.458,0.198 10 false CANH 2.854,2.771 3.313,2.969 0.458,0.198 10 false CANL
*a Component with harness connected
(No. 12 Global CAN Junction Connector)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G125)Location & Routing

Click Connector(G125)Body>Floor Wire / No. 3 Floor Wire>No. 12 Global CAN Junction Connector

G125-3 (CANH) - G125-14 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
G125-3 (CANH) - Body ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
G125-14 (CANL) - Body ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
G125-3 (CANH) - +B Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
G125-14 (CANL) - +B Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher



Result:
Result Proceed to
G125-3 (CANH) - G125-14 (CANL) is more than or equal to 70 Ω A
G125-3 (CANH) - G125-14 (CANL) is less than or equal to 54 Ω B
G125-3 (CANH) - Body ground is less than or equal to 200 Ω C
G125-14 (CANL) - Body ground is less than or equal to 200 Ω D
G125-3 (CANH) - +B is less than or equal to 6 kΩ E
G125-14 (CANL) - +B is less than or equal to 6 kΩ F
None of the above conditions are met G


Post-procedure1

a.

None



A

3.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

B

7.CHECK FOR SHORT IN CAN BUS WIRES (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

C

11.CHECK FOR SHORT IN CAN BUS WIRES (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

D

11.CHECK FOR SHORT IN CAN BUS WIRES (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

E

11.CHECK FOR SHORT IN CAN BUS WIRES (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

F

11.CHECK FOR SHORT IN CAN BUS WIRES (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

G

15.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BODY GROUND)
3.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

Pre-procedure1

a.

Disconnect the G125 No. 12 global CAN junction connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G125)Location & Routing

Click Connector(G125)Body>Floor Wire / No. 3 Floor Wire>No. 12 Global CAN Junction Connector

G125-2 (CANH) - G125-13 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

4.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

NG

5.CHECK FOR OPEN IN CAN BUS MAIN WIRE (BLIND SPOT MONITOR SENSOR LH)
4.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

Pre-procedure1

a.

Disconnect the G125 No. 12 global CAN junction connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G125)Location & Routing

Click Connector(G125)Body>Floor Wire / No. 3 Floor Wire>No. 12 Global CAN Junction Connector

G125-3 (CANH) - G125-14 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

REPLACE NO. 12 GLOBAL CAN JUNCTION CONNECTOR

NG

6.CHECK FOR OPEN IN CAN BUS MAIN WIRE (BLIND SPOT MONITOR SENSOR RH)
5.CHECK FOR OPEN IN CAN BUS MAIN WIRE (BLIND SPOT MONITOR SENSOR LH)

Pre-procedure1

a.

Reconnect the G125 No. 12 global CAN junction connector.


b.

Disconnect the G60 blind spot monitor sensor LH connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G60)Location & Routing

Click Connector(G60)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor LH

G60-1 (CA2P) - G60-6 (CA2N) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

NG

REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (BLIND SPOT MONITOR SENSOR LH - NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

6.CHECK FOR OPEN IN CAN BUS MAIN WIRE (BLIND SPOT MONITOR SENSOR RH)

Pre-procedure1

a.

Reconnect the G125 No. 12 global CAN junction connector.


b.

Disconnect the G56 blind spot monitor sensor RH connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G56)Location & Routing

Click Connector(G56)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor RH

G56-1 (CA2P) -G56-6 (CA2N) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

NG

REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (BLIND SPOT MONITOR SENSOR RH - NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

7.CHECK FOR SHORT IN CAN BUS WIRES (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

Pre-procedure1

a.

Disconnect the G125 No. 12 global CAN junction connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G125)Location & Routing

Click Connector(G125)Body>Floor Wire / No. 3 Floor Wire>No. 12 Global CAN Junction Connector

G125-2 (CANH) - G125-13 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

8.CHECK FOR SHORT IN CAN BUS WIRES (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

NG

9.CHECK FOR SHORT IN CAN BUS WIRES (BLIND SPOT MONITOR SENSOR LH)
8.CHECK FOR SHORT IN CAN BUS WIRES (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

Pre-procedure1

a.

Disconnect the G125 No. 12 global CAN junction connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G125)Location & Routing

Click Connector(G125)Body>Floor Wire / No. 3 Floor Wire>No. 12 Global CAN Junction Connector

G125-3 (CANH) - G125-14 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

REPLACE NO. 12 GLOBAL CAN JUNCTION CONNECTOR

NG

10.CHECK FOR SHORT IN CAN BUS WIRES (BLIND SPOT MONITOR SENSOR RH)
9.CHECK FOR SHORT IN CAN BUS WIRES (BLIND SPOT MONITOR SENSOR LH)

Pre-procedure1

a.

Reconnect the G125 No. 12 global CAN junction connector.


b.

Disconnect the G60 blind spot monitor sensor LH connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G60)Location & Routing

Click Connector(G60)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor LH

G60-1 (CA2P) - G60-6 (CA2N) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

NG

REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (BLIND SPOT MONITOR SENSOR LH - NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

10.CHECK FOR SHORT IN CAN BUS WIRES (BLIND SPOT MONITOR SENSOR RH)

Pre-procedure1

a.

Reconnect the G125 No. 12 global CAN junction connector.


b.

Disconnect the G56 blind spot monitor sensor RH connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G56)Location & Routing

Click Connector(G56)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor RH

G56-1 (CA2P) -G56-6 (CA2N) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

NG

REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (BLIND SPOT MONITOR SENSOR RH - NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

11.CHECK FOR SHORT IN CAN BUS WIRES (NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

Pre-procedure1

a.

Disconnect the G125 No. 12 global CAN junction connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G125)Location & Routing

Click Connector(G125)Body>Floor Wire / No. 3 Floor Wire>No. 12 Global CAN Junction Connector

G125-2 (CANH) - Body ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
G125-13 (CANL) - Body ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
G125-2 (CANH) - +B Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
G125-13 (CANL) - +B Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

12.CHECK FOR SHORT IN CAN BUS WIRES (NO. 12 CAN JUNCTION CONNECTOR)

NG

13.CHECK FOR SHORT IN CAN BUS WIRES (BLIND SPOT MONITOR SENSOR LH)
12.CHECK FOR SHORT IN CAN BUS WIRES (NO. 12 CAN JUNCTION CONNECTOR)

Pre-procedure1

a.

Disconnect the G125 No. 12 global CAN junction connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G125)Location & Routing

Click Connector(G125)Body>Floor Wire / No. 3 Floor Wire>No. 12 Global CAN Junction Connector

G125-3 (CANH) - Body ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
G125-14 (CANL) - Body ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
G125-3 (CANH) - +B Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
G125-14 (CANL) - +B Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

REPLACE NO. 12 GLOBAL CAN JUNCTION CONNECTOR

NG

14.CHECK FOR SHORT IN CAN BUS WIRES (BLIND SPOT MONITOR SENSOR RH)
13.CHECK FOR SHORT IN CAN BUS WIRES (BLIND SPOT MONITOR SENSOR LH)

Pre-procedure1

a.

Reconnect the G125 No. 12 global CAN junction connector.


b.

Disconnect the G60 blind spot monitor sensor LH connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G60)Location & Routing

Click Connector(G60)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor LH

G60-1 (CA2P) - Body ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
G60-6 (CA2N) - Body ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
G60-1 (CA2P) - +B Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
G60-6 (CA2N) - +B Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

NG

REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (BLIND SPOT MONITOR SENSOR LH - NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

14.CHECK FOR SHORT IN CAN BUS WIRES (BLIND SPOT MONITOR SENSOR RH)

Pre-procedure1

a.

Reconnect the G125 No. 12 CAN junction connector.


b.

Disconnect the G56 blind spot monitor sensor RH connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G56)Location & Routing

Click Connector(G56)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor RH

G56-1 (CA2P) - Body ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
G56-6 (CA2N) - Body ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
G56-1 (CA2P) - +B Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
G56-6 (CA2N) - +B Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

NG

REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (BLIND SPOT MONITOR SENSOR RH - NO. 12 GLOBAL CAN JUNCTION CONNECTOR)

15.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BODY GROUND)

Pre-procedure1

a.

Reconnect the cable to the negative (-) auxiliary battery terminal.


b.

Disconnect the G60 blind spot monitor sensor LH connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G60)Location & Routing

Click Connector(G60)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor LH

G60-10 (BLGD) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG


Post-procedure1


OK

16.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH POWER SOURCE)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

16.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH POWER SOURCE)

Pre-procedure1

a.

Disconnect the G60 blind spot monitor sensor LH connector.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition

Click Location & Routing(G60)Location & Routing

Click Connector(G60)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor LH

G60-5 (BLB) - Body ground Ignition switch ON 11 to 14 V
G60-5 (BLB) - Body ground Ignition switch off Below 1 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

17.CLEAR DTC

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

17.CLEAR DTC
a.

Clear the DTCs.

Body Electrical > Blind Spot Monitor Master > Clear DTCs
50002 313

Result:
Proceed to
NEXT



NEXT

18.CHECK FOR DTC
18.CHECK FOR DTC
a.

Check for DTCs.

Body Electrical > Blind Spot Monitor Master > Trouble Codes
50001 313

Result:
Result Proceed to
DTCs are not output A
DTCs are output B



A

B

19.REPLACE BLIND SPOT MONITOR SENSOR LH
19.REPLACE BLIND SPOT MONITOR SENSOR LH
a.

Replace the blind spot monitor sensor LH.

HINT:

Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>BLIND SPOT MONITOR SENSOR>REMOVAL



Result:
Proceed to
NEXT



NEXT

20.CLEAR DTC
20.CLEAR DTC
a.

Clear the DTCs.

Body Electrical > Blind Spot Monitor Master > Clear DTCs
50002 313

Result:
Proceed to
NEXT



NEXT

21.CHECK FOR DTC
21.CHECK FOR DTC
a.

Check for DTCs.

Body Electrical > Blind Spot Monitor Master > Trouble Codes
50001 313

Result:
Result Proceed to
DTCs are not output A
DTCs are output B



A

END

B