Home › ENGINE › 1NZ-FXE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0136    Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2)

DTC    P0137    Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2)

DTC    P0138    Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2)

DTC    P0139    Oxygen Sensor Circuit Slow Response (Bank 1 Sensor 2)

for Preparation Click here


DESCRIPTION

A three-way catalist converter (TWC) is used in order to convert the carbon monoxide (CO), hydrocarbons (HC), and nitrogen oxide (Nox) into less harmful substrances. To allow the TWC to function effectively, it is necessary to keep the air-fuel ratio of the engine near the stoichiometric air-fuel ratio. For the purpose of helping the ECM to deliver accurate air-fuel ratio control, a Heated Oxygen (HO2) sensor is used.
The HO2 sensor is located behind the TWC, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with the heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air-fuel ratio becomes lean, the oxygen concentration in the exhaust gas is rich. The HO2 sensor informs the ECM that the post-TWC air-fuel ratio is lean (low voltage, i.e. less than 0.45 V).
Conversely, when the air-fuel ratio is richer than the stoichiometric air-fuel level, the oxygen concentration in the exhaust gas becomes lean. The HO2 sensor informs the ECM that the post-TWC air-fuel ratio is rich (high voltage, i.e. more than 0.45 V). The HO2 sensor has the property of changing its output voltage drastically when the air-fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the HO2 sensor to determine whether the air-fuel ratio after the TWC is rich or lean, and adjusts the fuel injection time accordingly. Thus, if the HO2 sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in the primary air-fuel ratio control.

A165054E01


DTC No.
DTC Detection Condition
Trouble Area
P0136
  1. Abnormal voltage output:
    During active air-fuel ratio control, following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):
    1. (a) Heated Oxygen (HO2) sensor voltage does not decrease to less than 0.59 V
    1. (b) HO2 sensor voltage does not increase to more than 0.21 V
  1. Low impedance:
    1. Sensor impedance less than 5 Ω for more than 30 seconds when ECM presumes sensor to be warmed up and operating normally (2 trip detection logic)
  1. Open or short in HO2 sensor (sensor 2) circuit
  2. HO2 sensor (sensor 2)
  3. HO2 sensor heater (sensor 2)
  4. Air-fuel ratio (A/F) sensor (sensor 1)
  5. Integration relay (EFI M relay)
  6. Gas leakage from exhaust system
P0137
  1. Low voltage (open):
    During active air-fuel ratio control, following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):
    1. (a) HO2 sensor voltage output less than 0.21 V
    1. (b) Target air-fuel ratio rich
  1. High impedance:
    1. Sensor impedance 15 kΩ or more for more than 90 seconds when ECM presumes sensor to be warmed up and operating normally (2 trip detection logic)
  1. Open in HO2 sensor (sensor 2) circuit
  2. HO2 sensor (sensor 2)
  3. HO2 sensor heater (sensor 2)
  4. Integration relay (EFI M relay)
  5. Gas leakage from exhaust system
P0138
  1. High voltage (short):
    During active air-fuel ratio control, following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):
    1. (a) HO2 sensor voltage output more than 0.59 V
    1. (b) Target air-fuel ratio lean
  1. Extremely high voltage (short):
    1. HO2 sensor voltage output exceeds 1.2 V for more than 10 seconds (2 trip detection logic)
  1. Short in HO2 sensor (sensor 2) circuit
  2. HO2 sensor (sensor 2)
  3. ECM internal circuit malfunction
P0139
Heated oxygen sensor (sensor 2) voltage does not drop to below 0.2 V immediately air fuel cut status
  1. Short in HO2 sensor (sensor 2) circuit
  2. HO2 sensor (sensor 2)
  3. ECM internal circuit malfunction
  4. A/F sensor (sensor 1)

MONITOR DESCRIPTION

  1. Active Air-Fuel Ratio Control:
    The ECM usually performs air-fuel ratio feedback control so that the Air-Fuel Ratio (A/F) sensor output indicates a near stoichiometric air-fuel level. This vehicle includes active air-fuel ratio control in addition to regular air-fuel ratio control. The ECM performs active air-fuel ratio control to detect any deterioration in the Three-Way Catalytic Converter (TWC) and Heated Oxygen (HO2) sensor malfunctions (refer to the diagram below).
    Active air-fuel ratio control is performed for approximately 15 to 20 seconds while driving with a warm engine. During active air-fuel ratio control, the air-fuel ratio is forcibly regulated to become lean or rich by the ECM. If the ECM detects a malfunction, one of the following DTCs is set: DTC P0136 (abnormal voltage output), P0137 (open circuit) and P0138 (short circuit).
  1. Abnormal Voltage Output of HO2 Sensor (DTC P0136):
    While the ECM is performing active air-fuel ratio control, the air-fuel ratio is forcibly regulated to become rich or lean. If the sensor is not functioning properly, the voltage output variation is small. For example, when the HO2 sensor voltage does not decrease to less than 0.21 V and does not increase to more than 0.59 V during active air-fuel ratio control, the ECM determines that the sensor voltage output is abnormal and sets DTC P0136.

    A115540E02

  1. Open or Short in Heated Oxygen (HO2) Sensor Circuit (DTC P0137 or P0138):
    During active air-fuel ratio control, the ECM calculates the Oxygen Storage Capacity (OSC)* of the Three-Way Catalytic Converter (TWC) by forcibly regulating the air-fuel ratio to become rich or lean. If the HO2 sensor has an open or short, or the voltage output of the sensor decreases significantly, the OSC indicates an extraordinarily high value. Even if the ECM attempts to continue regulating the air-fuel ratio to become rich or lean, the HO2 sensor output does not change.
    While performing active air-fuel ratio control, when the target air-fuel ratio is rich and the HO2 sensor voltage output is 0.21 V or less (lean), the ECM interprets this as an abnormally low sensor output voltage and sets DTC P0137. When the target air-fuel ratio is lean and the voltage output is 0.59 V or more (rich) during active air-fuel ratio control, the ECM determines that the sensor voltage output is abnormally high, and sets DTC P0138.

    HINT:
    DTC P0138 is also set if the HO2 sensor voltage output is more than 1.2 V for 10 seconds or more.

    *: The TWC has the capability to store oxygen. The OSC and the emission purification capacity of the TWC are mutually related. The ECM determines whether the catalyst has deteriorated based on the calculated OSC value (Click here).

    A115541E02

  1. High or Low Impedance of Heated Oxygen (HO2) Sensor (DTC P0136 or P0137):
    A076841E04
    During normal air-fuel ratio feedback control, there are small variations in the exhaust gas oxygen concentration. In order to continuously monitor the slight variations in the HO2 sensor signal while the engine is running, the impedance* of the sensor is measured by the ECM. The ECM determines that there is a malfunction in the sensor when the measured impedance deviates from the standard range.
    *: The effective resistance in an alternating current electrical circuit.

    HINT:
    1. The impedance cannot be measured using an ohmmeter.
    2. DTC P0136 indicates the deterioration of the HO2 sensor. The ECM sets this DTC by calculating the impedance of the sensor when the typical enabling conditions are satisfied (2 driving cycles).
    3. DTC P0137 indicates an open or short circuit in the HO2 sensor (2 driving cycles). The ECM sets this DTC when the impedance of the sensor exceeds the threshold 15 kΩ.

  1. Abnormal Voltage Output of Heated Oxygen Sensor During Fuel-cut (DTC P0139)
    The sensor output voltage drops to below 0.2 V (extremely Lean status) immediately when the vehicle decelerates and fuel cut is operating. If the voltage does not drop to below 0.2 V, the ECM determines that the sensor's response feasure has deteriorated, illuminates the MIL and sets a DTC.

MONITOR STRATEGY


Related DTCs
P0136: Heated oxygen sensor output voltage (Abnormal voltage output)
P0136: Heated oxygen sensor impedance (Low)
P0137: Heated oxygen sensor output voltage (Low voltage)
P0137: Heated oxygen sensor impedance (High)
P0138: Heated oxygen sensor output voltage (High voltage)
P0138: Heated oxygen sensor output voltage (Extremely high)
P0139: Heated oxygen sensor output voltage during fuel cut (Bank 1)
Required Sensors/Components (Main)
Heated oxygen sensor
Required Sensors/Components (Related)
Crankshaft position sensor, engine coolant temperature sensor, mass air flow meter and throttle position sensor
Frequency of Operation
Once per driving cycle: Active air-fuel ratio control detection
Continuous: Other
Duration
20 seconds: Heated oxygen sensor output voltage (Abnormal voltage output, High voltage and Low voltage)
55 seconds: Heated oxygen sensor impedance (High)
30 seconds: Heated oxygen sensor impedance (Low)
10 seconds: Output voltage (Extremely high)
6 seconds: Output voltage (During fuel-cut)
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


All: 
Monitor runs whenever following DTCs are not present
P0031, P0032 (A/F sensor heater - sensor 1)
P0037, P0038 (O2 sensor heater - sensor 2)
P0100 - P0103 (MAF meter)
P0110 - P0113 (IAT sensor)
P0115 - P0118 (ECT sensor)
P0120 - P0223, P2135 (TP sensor)
P0125 (Insufficient ECT for closed loop)
P0171, P0172 (Fuel system)
P0300 - P0304 (Misfire)
P0335 (CKP sensor)
P0340, P0341 (CMP sensor)
P0451 - P0456 (EVAP system)
P0500 (VSS)
P2196 (A/F Sensor - rationality)
P2237 (A/F Sensor - open)
P2A00 (A/F Sensor - slow response)

Heated Oxygen Sensor Output Voltage (Abnormal Voltage Output, High Voltage and Low Voltage): 
Active air-fuel ratio control
Performing
Active air-fuel ratio control is performed when the following conditions are met:
-
Battery voltage
11 V or more
Engine coolant temperature
75°C (167°F) or more
Idling
OFF
Engine RPM
Less than 3200 rpm
A/F sensor status
Activated
Fuel system status
Closed loop
Fuel cut
OFF
Engine load
10 to 70 %

Heated Oxygen Sensor Impedance (Low): 
Estimated rear HO2 sensor temperature
Less than 750°C (1,382°F)

Heated Oxygen Sensor Impedance (High): 
Estimated rear HO2 sensor temperature
450°C (842°F) or more
Intake air amount
More than 0 g/sec.

Heated Oxygen Sensor Output Voltage (Extremely High): 
Battery voltage
10.5 V or more
Engine
Running

Heated Oxygen Sensor Output Voltage (During fuel-cut): 
Engine coolant temperature
70°C (158°F) or more
Estimated catalyst temperature
430°C(806°F) or more
Fuel-cut
ON

TYPICAL MALFUNCTION THRESHOLDS


Heated Oxygen Sensor Output Voltage (Abnormal Voltage Output): 
Either of the following conditions is met:
1 or 2
1. All of the following conditions (a), (b) and (c) are met
-
(a) Commanded air-fuel ratio
14.3 or less
(b) Rear HO2 sensor voltage
0.21 to 0.59 V
(c) OSC (Oxygen Storage Capacity of Catalyst)
1.2 g or more
2. All of the following conditions (d), (e) and (f) are met
-
(d) Commanded air-fuel ratio
14.9 or more
(e) Rear HO2 sensor voltage
0.21 to 0.59 V
(f) OSC (Oxygen Storage Capacity of Catalyst)
1.2 g or more

Heated Oxygen Sensor Output Voltage (Low): 
All of the following conditions (a), (b) and (c) are met
-
(a) Commanded air-fuel ratio
14.3 or less
(b) Rear HO2 sensor voltage
Less than 0.21 V
(c) OSC (Oxygen Storage Capacity of Catalyst)
1.2 g or more

Heated Oxygen Sensor Output Voltage (High): 
All of the following conditions (a), (b) and (c) are met
-
(a) Commanded air-fuel ratio
14.9 or more
(b) Rear HO2 sensor voltage
More than 0.59 V
(c) OSC (Oxygen Storage Capacity of Catalyst)
1.2 g or more

Heated Oxygen Sensor Impedance (Low): 
Rear HO2 sensor impedance
Less than 5 Ω

Heated Oxygen Sensor Impedance (High): 
Rear HO2 sensor impedance
15 kΩ or more

Heated Oxygen Sensor Output Voltage (Extremely High): 
Rear HO2 sensor voltage
1.2 V or more

Heated Oxygen Sensor Output Voltage (During fuel-cut): 
Duration until HO2 sensor voltage drops to 0.2 V during fuel-cut
6 seconds or more

COMPONENT OPERATING RANGE


Duration of the following condition is met
30 seconds or more
Heated oxygen sensor voltage
Varies between 0.1 and 0.9 V

MONITOR RESULT

Refer to CHECKING MONITOR STATUS (Click here).

WIRING DIAGRAM


A151889E02


CONFIRMATION DRIVING PATTERN

HINT:
  1. This confirmation driving pattern is used in the "PERFORM CONFIRMATION DRIVING PATTERN" procedure of the following diagnostic troubleshooting procedure.
  2. Performing this confirmation pattern will activate the Heated Oxygen (HO2) sensor monitor. (The catalyst monitor is performed simultaneously.) This is very useful for verifying the completion of the repair.


A182948E01

  1. Connect Techstream to the DLC3.
  2. Warm-up the engine until the engine coolant temperature is 75°C (167°F) or more [A].
  3. Drive the vehicle at between 55 mph and 75 mph (88 km/h and 120 km/h) for at least 10 minutes [B].
  4. Drive the vehicle 55 mph (88 km/h) or more and decelerate for 40 mph (64 km/h) the vehicle for 5 seconds or more. Perform this 3 times [C].
  5. Turn the tester on.
  6. Select the following menu items: Powertrain / Engine and ECT / Utility / All Readiness.
  7. Input DTCs: P0136, P0137, P0138 and P0139.
  8. Check that DTC MONITOR is NORMAL. If DTC MONITOR is incomplete, perform the drive pattern adding the vehicle speed and using the B position to decelerate the vehicle.
  9. Note the state of the Readiness Tests items. Those items will change to complete as the O2S EVAL monitor operates.
  10. On the tester, select the following menu items: Powertrain / Engine and ECT / Trouble Code / Pending. and check if any DTCs (any pending DTCs) are set.

HINT:
If O2S EVAL does not change to Complete, and any pending DTCs fail to set, extend the driving time.


INSPECTION PROCEDURE

HINT:
Sensor 2 refers to the sensor mounted behind the Three-Way Catalytic Converter (TWC) and located far from the engine assembly.

HINT:
Techstream only:
Malfunctioning areas can be identified by performing the Control the Injection Volume for A/F Sensor function provided in the Active Test. The Control the Injection Volume for A/F Sensor function can help to determine whether the Air-Fuel Ratio (A/F) sensor, Heated Oxygen (HO2) sensor and other potential trouble areas are malfunctioning.

  1. The following instructions describe how to conduct the Control the Injection Volume for A/F Sensor operation using Techstream.
    1. Connect Techstream to the DLC3.
    2. Start the engine and turn the tester on.
    3. Warm up the engine at an engine speed of 2,500 rpm for approximately 90 seconds.
    4. On the tester, select the following menu items: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.
    5. Perform the Control the Injection Volume for A/F Sensor operation with the engine idling (press the RIGHT or LEFT button to change the fuel injection volume).
    6. Monitor the voltage outputs of the A/F and HO2 sensors (AFS B1 S1 and O2S B1 S2) displayed on the tester.

HINT:
  1. The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5 % or increases the injection volume by 25 %.
  2. The sensors react in accordance with increases and decreases in the fuel injection volume.


Standard:

Tester Display
(Sensor)
Injection Volumes
Status
Voltages
AFS B1 S1
(A/F)
+25 %
Rich
Less than 3.0
-12.5 %
Lean
More than 3.35
O2S B1 S2
(HO2)
+25 %
Rich
More than 0.5
-12.5 %
Lean
Less than 0.4

NOTICE:
The A/F sensor has an output delay of a few seconds and the HO2 sensor has a maximum output delay of approximately 20 seconds.


Case
A/F Sensor (Sensor 1)
Output Voltage
HO2 Sensor (Sensor 2)
Output Voltage
Main Suspected Trouble Area
1
A150444E03
A150447E02
A150444E03
A150446E02
-
2
A150444E03
A150445E02
A150444E03
A150446E02
  1. A/F sensor
  2. A/F sensor heater
  3. A/F sensor circuit
3
A150444E03
A150447E02
A150444E03
A150445E02
  1. HO2 sensor
  2. HO2 sensor heater
  3. HO2 sensor circuit
4
A150444E03
A150445E02
A150444E03
A150445E02
  1. Fuel pressure
  2. Gas leakage from exhaust system
    (Air-fuel ratio extremely lean or rich)
  1. Following the Control the Injection Volume for A/F Sensor procedure enables technicians to check and graph the voltage outputs of both the A/F and HO2 sensors.
  2. To display the graph, select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / A/F Control System / AFS B1 S1 and O2S B1 S2 then press the graph button on the Data List view.

HINT:
  1. Read freeze frame data using Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air/fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
  2. If the OX1B wire from the ECM connector is short-circuited to the +B wire, DTC P0138 will be set.

1.READ OUTPUT DTC
  1. Connect Techstream to the DLC3.

  1. Turn the power switch ON (IG) and turn the tester on.

  1. Select the following menu items: Powertrain / Engine and ECT / Trouble Code.

  1. Read the DTCs.

    Result:

    Display (DTC output)
    Proceed to
    P0138 or P0139
    A
    P0137
    B
    P0136
    C



B
Go to step 8

C
Go to step 6
A


2.READ VALUE OF TECHSTREAM (OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)
  1. Connect Techstream to the DLC3.

  1. Turn the power switch ON (IG) and turn the tester on.

  1. Select the following menu items: Powertrain / Engine and ECT / Trouble Code.

  1. Allow the engine to idle.

  1. Read the Heated Oxygen (HO2) sensor output voltage while idling.

    Result:

    Tester Display
    Result
    O2S B1S2
    Less than 1.0 V



OK
Go to step 5
NG


Go to step 4

3.INSPECT HEATED OXYGEN SENSOR (CHECK FOR SHORT)


    A062378E36
  1. Disconnect the H13 Heated Oxygen sensor connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    2 (+B) - E (4)
    10 kΩ or higher
    2 (+B) - 3 (OX)
    10 kΩ or higher

  1. Reconnect the Heated Oxygen sensor connector.



NG
REPLACE HEATED OXYGEN SENSOR
OK


4.CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT)


    A065748E30
  1. Turn the power switch off and wait for 5 minutes.

  1. Disconnect the E6 ECM connector.

  1. Measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Specified Condition
    E6-6 (HT1B) - E6-22 (OX1B)
    10 kΩ or higher

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM 

5.CHECK AIR FUEL RATIO SENSOR

HINT:
This A/F sensor test is to check the A/F sensor current during fuel-cut. When the sensor is normal, the sensor current will indicate below 3.0 mA in this test.

  1. Connect Techstream to the DLC3.

  1. Turn the power switch ON (IG).

  1. Turn the tester on.



  1. Drive the vehicle according to the drive pattern listed below:

    1. Warm up the engine until the engine coolant temperature reaches 75°C (167°F) or more.

    2. Drive the vehicle at 55 mph (88 km/h) or more and decelerate the vehicle for 10 seconds or more.



    3. Repeat the deceleration above at least 3 times.


      A183408E01

  1. Select the following menu items: Powertrain / Engine and ECT / Monitor / O2 Sensor / Details.

  1. Confirm that RANGE B1S1 is either Pass or Fail. If the tester shows Incomplete, re-check RANGE B1S1 after performing the drive pattern.

  1. Select the RANGE B1S1.

  1. Read the Test Value.

    Standard current:
    Less than 3.0 mA

HINT:
If the tester shows Incomplete again, increase vehicle speed and use the B position to decelerate the vehicle. Refer to the CONFIRMATION DRIVING PATTERN.



OK
Go to step 11

NG
Go to step 14

6.READ VALUE USING TECHSTREAM (OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)
  1. Connect Techstream to the DLC3.

  1. Turn the power switch ON (IG) and turn the tester on.

  1. Start the engine.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / A/F Control System / O2S B1 S2.

  1. After warming up the engine, run the engine at an engine speed of 2,500 rpm for 3 minutes.

  1. Read the output voltage of the Heated Oxygen sensor when the engine rpm is suddenly increased.

    HINT:
    Quickly accelerate the engine to 4,000 rpm 3 times using the accelerator pedal.

    Standard voltage:
    Fluctuates between 0.4 V or less and 0.5 V or more.



NG
Go to step 8
OK


7.PERFORM ACTIVE TEST USING TECHSTREAM (INJECTION VOLUME)

A121606E02

  1. Connect Techstream to the DLC3.

  1. Start the engine and turn the tester on.

  1. Warm up the engine.

  1. Select the following menu items: Powertrain / Engine and ECT / Active Test / Control the Injection Volume.

  1. Change the fuel injection volume using the tester, and monitor the voltage output of Air-Fuel Ratio (A/F) and Heated Oxygen sensors displayed on the tester.

HINT:
  1. Change the fuel injection volume within the range of -12 % and +12 %. The injection volume can be changed in 1 % graduations within the range.
  2. The A/F sensor is displayed as AFS B1 S1, and the Heated Oxygen sensor is displayed as O2S B1 S2, on Techstream.

    Result:

    Tester Display (Sensor)
    Voltage Variations
    Proceed to
    AFS B1 S1 (A/F)
    Alternates between more and less than 3.3 V
    OK
    Remains at more than 3.3 V
    NG
    Remains at less than 3.3 V
    NG

    HINT:
    A normal Heated Oxygen sensor voltage (O2S B1 S2) reacts in accordance with increases and decreases in fuel injection volumes. When the A/F sensor voltage remains at either less or more than 3.3 V despite the Heated Oxygen sensor indicating a normal reaction, the A/F sensor is malfunctioning.



NG
REPLACE AIR FUEL RATIO SENSOR
OK

CHECK AND REPAIR EXTREMELY RICH OR LEAN ACTUAL AIR-FUEL RATIO (INJECTOR, FUEL PRESSURE, GAS LEAKAGE FROM EXHAUST SYSTEM, ETC.) 

8.INSPECT FOR EXHAUST GAS LEAK

OK:
No gas leakage.



NG
REPAIR OR REPLACE EXHAUST GAS LEAKAGE POINT
OK


Go to step 11

9.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)


    A062378E36
  1. Disconnect the H13 heated oxygen sensor connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 (HT) - 2 (+B)
    11 to 16 Ω at 20°C (68°F)
    1 (HT) - 4 (E)
    10 kΩ or higher

  1. Reconnect the heated oxygen sensor connector.



NG
REPLACE HEATED OXYGEN SENSOR
OK


10.INSPECT INTEGRATION RELAY (EFI M RELAY)


    A082812E01
  1. Remove the integration relay from the engine room relay block.

  1. Inspect the EFI M relay.

    Standard resistance:
    Tester Connection
    Specified Condition
    3K-1 - 3I-8
    10 kΩ or higher
    3K-1 - 3I-8
    Below 1 Ω
    (Apply battery voltage to terminals 3I-6 and 3I-7)

  1. Reinstall the integration relay.



NG
REPLACE INTEGRATION RELAY
OK


11.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)


    A079118E08
  1. Disconnect the H13 heated oxygen sensor connector.

  1. Turn the power switch ON (IG).

  1. Measure the voltage between the +B terminal of the heated oxygen sensor connector and body ground.

    Standard voltage:
    Tester Connection
    Specified Condition
    H13-2 (+B) - Body ground
    9 to 14 V

  1. Turn the power switch off.



    A079127E05
  1. Disconnect the E4 and E6 ECM connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    H13-1 (HT) - E6-6 (HT1B)
    Below 1 Ω
    H13-3 (OX) - E6-22 (OX1B)
    Below 1 Ω
    H13-4 (E) - E4-28 (E2)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    H13-1 (HT) or E6-6 (HT1B) - Body ground
    10 kΩ or higher
    H13-3 (OX) or E6-22 (OX1B) - Body ground
    10 kΩ or higher
    H13-4 (E) or E4-28 (E2) - Body ground
    10 kΩ or higher

  1. Reconnect the heated oxygen sensor connector.

  1. Reconnect the ECM connectors.


B062793E26



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


12.REPLACE HEATED OXYGEN SENSOR
  1. Replace the heated oxygen sensor.


NEXT


Go to step 15

13.PERFORM CONFIRMATION DRIVING PATTERN

A182948E01

  1. Connect Techstream to the DLC3.

  1. Warm-up the engine until the engine coolant temperature is 75°C (167°F) or more [A].

  1. Drive the vehicle at between 55 mph and 75 mph (88 km/h and 120 km/h) for at least 10 minutes [B].

  1. Drive the vehicle 55 mph (88 km/h) or more and decelerate for 40 mph (64 km/h) the vehicle for 5 seconds or more. Perform this 3 times [C].

  1. Turn the tester on.

  1. Select the following menu items: Powertrain / Engine and ECT / Utility / All Readiness.

  1. Input DTCs: P0136, P0137, P0138 and P0139.

  1. Check that DTC MONITOR is NORMAL. If DTC MONITOR is incomplete, perform the drive pattern adding the vehicle speed and using the B position to decelerate the vehicle.

  1. Note the state of the Readiness Tests items. Those items will change to complete as the O2S EVAL monitor operates.

  1. On the tester, select the following menu items: Powertrain / Engine and ECT / Trouble Code / Pending. and check if any DTCs (any pending DTCs) are set.



NG
REPLACE AIR FUEL RATIO SENSOR
OK

REPAIR COMPLETE 

14.REPLACE AIR FUEL RATIO SENSOR
  1. Replace the air fuel ratio sensor.


NEXT


15.PERFORM CONFIRMATION DRIVING PATTERN

A182948E01

  1. Connect Techstream to the DLC3.

  1. Warm-up the engine until the engine coolant temperature is 75°C (167°F) or more [A].

  1. Drive the vehicle at between 55 mph and 75 mph (88 km/h and 120 km/h) for at least 10 minutes [B].

  1. Drive the vehicle 55 mph (88 km/h) or more and decelerate for 40 mph (64 km/h) the vehicle for 5 seconds or more. Perform this 3 times [C].

  1. Turn the tester on.

  1. Select the following menu items: Powertrain / Engine and ECT / Utility / All Readiness.

  1. Input DTCs: P0136, P0137, P0138 and P0139.

  1. Check that DTC MONITOR is NORMAL. If DTC MONITOR is incomplete, perform the drive pattern adding the vehicle speed and using the B position to decelerate the vehicle.

  1. Note the state of the Readiness Tests items. Those items will change to complete as the O2S EVAL monitor operates.

  1. On the tester, select the following menu items: Powertrain / Engine and ECT / Trouble Code / Pending. and check if any DTCs (any pending DTCs) are set.



NG
REPLACE HEATED OXYGEN SENSOR
OK

REPAIR COMPLETE