Technicians to be engaged in inspection and service on high-voltage components and systems should receive special training.
All the high-voltage wire harness connectors are colored orange: the HV battery and other high-voltage components are identified by the "High Voltage" caution labels.
Do not touch these connectors and components before removing the service plug. Remove the service plug prior to touching these connectors and components.
Before inspecting or servicing the high-voltage components/systems, be sure to take safe precautions such as wearing insulated gloves and removing the service plug to prevent electric shock or electrocution. Store the removed service plug in your pocket to prevent other technicians from reinstalling it while you are servicing high-voltage components/systems.
After removing the service plug, wait at least for 5 minutes before touching any of the high-voltage connectors and terminals.
- HINT:
- At least 5 minutes are required to discharge electricity from the high-voltage condenser inside the inverter.
Before wearing insulated gloves, make sure that they are not rupture, torn or damaged in any other way. Do not wear wet insulated gloves.
When servicing, be careful not to drop metallic materials like a mechanical pencil or tools, etc. A short circuit may result.
Wear the insulated gloves before touching a bare high-voltage terminal. Verify that electricity has discharged from the terminal (approximately 0 V) using an electrical tester.
After disconnecting or exposing a high-voltage connector or terminal, insulate it immediately using insulation tape.
The screw of a high-voltage terminal should be tightened firmly to the specified torque. Either insufficient or excessive tightening torque can cause HV system failure.
Call other technicians' attention to prevent accidents during working on the high-voltage components/systems by posting a sign to notify them (Click here).
Prior to reinstalling the service plug, again, verify whether or not any parts or tools have been left behind, and check if high-voltage terminal screws have been securely tightened as well as the connectors have been properly reconnected.