Home › ENGINE › 1NZ-FXE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P1455    Vapor Reducing Fuel Tank System Malfunction

for Preparation Click here


DESCRIPTION

Using the heated oxygen sensor and pressure switching VSV, the ECM detects fuel leaks from inside of a bladder tank in the fuel tank.
Based on signals from the heated oxygen sensor while the VSV for purge flow switching valve is ON, the ECM judges if fuel is leaked from the bladder tank or not.

DTC No.
DTC Detection Condition
Trouble Area
P1455
When VSV for purge flow switching valve is ON, vapor density of air which flows from purge VSV into intake manifold is high
  1. Fuel tank
  2. Fuel system
  3. ECM

MONITOR DESCRIPTION

The ECM detects leakage of evaporative emissions from the bladder membrane by using the heated oxygen sensor and purge flow switching valve. By opening the purge VSV and then closing the purge flow switching valve, air in the outer tank is drawn into the intake manifold.
The ECM checks concentration of hydrocarbon (HC) molecules in the air drawn from the bladder membrane area. Also, the ECM checks the sensor output before and after closing the purge flow switching valve. If there is change in the HC concentration when the purge flow switching valve is opened or closed, the ECM will conclude that the bladder membrane is leaking. The ECM will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P1455: Vapor reducing fuel tank system leak detected (small leak) monitor
Required sensors/components (main)
Fuel tank
Frequency of operation
Once per driving cycle
Duration
None
MIL operation
2 driving cycles
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTC not present
None
Engine
Running
ECT
4.4°C (40°F) or more
IAT
4.4°C (40°F) or more
EVAP control system pressure sensor malfunction
Not detected
Purge VSV
Not detected by scan tool
EVAP system check
Not detected by scan tool
Battery voltage
11 V or higher
Purge duty cycle
15% or more

TYPICAL MALFUNCTION THRESHOLDS


Vapor concentration in purge air
Less than -7 to -4% (depending on intake air temperature)
FAF smoothing value
Less than 5%
VSV for purge flow switching valve
No malfunction
Purge air volume after purge flow switching valve monitoring
2 g or more

MONITOR RESULT

Refer to detailed information (Click here).

INSPECTION PROCEDURE

HINT:
Read freeze frame data using Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air/fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.CHECK OTHER DTC OUTPUT (IN ADDITION TO DTC P1455)
  1. Connect Techstream to the DLC3.

  1. Turn the power switch ON (IG).

  1. Turn the tester ON.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Code.

  1. Read DTCs.

    Result:
    Display (DTC Output)
    Proceed to
    P1455
    A
    P1455 and other DTCs
    B

    HINT:
    If any other codes besides P1455 are output, perform troubleshooting for those DTCs first.



B
GO TO DTC CHART
A


2.INSPECT FUEL TANK ASSEMBLY
  1. Remove the fuel tank (Click here).

  1. Drain fuel from the tank and turn it upside down.

    OK:
    Fuel does not come out from anywhere except the main fuel hose.



OK
REPLACE ECM
NG

REPLACE FUEL TANK ASSEMBLY