Home › ENGINE › 1NZ-FXE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P1121    Coolant Flow Control Valve Position Sensor Circuit Stuck

for Preparation Click here


DESCRIPTION

Refer to DTC P1120 .

DTC No.
DTC Detection Condition
Trouble Area
P1121
  1. Water valve position sensor output voltage:
    No change despite the ECM sending a valve control signal or slow response
  2. CHS tank outlet temperature sensor output:
    60°C (140°F) or more (when hot coolant recovering starts)
  3. CHS tank outlet temperature sensor output:
    No change although the hot coolant is recovered
  1. Water valve
  2. Cooling system (clogging)
  3. ECM

MONITOR DESCRIPTION


A082804E01

The ECM monitors the position of the water valve based on the valve position signal that is output by the water valve position sensor (potentiometer), which is coupled coaxially to the valve. The water valve effects control in three steps as indicated above, and the ECM determines the position of the valve according to the voltage of the respective step.
In order to ensure the proper monitoring of the water valve, the ECM checks for malfunctions with the combination of the output of the potentiometer and CHS tank outlet temperature sensor.
If no changes occur in the valve position signal that is being input into the ECM or if the response signal from the water valve is very slow, despite the ECM commanding the water valve motor to operate the ECM determines that a malfunction has occurred in the water valve position sensor circuit, and sets a DTC.

MONITOR STRATEGY


Potentiometer detection 
Related DTCs
P1121: Coolant flow control valve position sensor circuit stuck
Required sensors/components
Main:
Water valve
Related:
CHS tank outlet temperature sensor
Frequency of operation
Once per driving cycle
Duration
20 seconds
MIL operation
2 driving cycle
Sequence of operation
None

Tank outlet coolant temperature detection 
Related DTCs
P1121: Coolant flow control valve position sensor circuit stuck
Required sensors/components
Main:
Water valve
Related:
CHS tank outlet temperature sensor
Frequency of operation
Once per driving cycle
Duration
10 seconds
MIL operation
2 driving cycle
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


Potentiometer detection 
The monitor will run whenever the following DTCs are not present
None
Coolant heat storage system malfunction
Not detected
Battery voltage
10 V or more
Engine coolant temperature
0°C (32°F) or more
Water valve operation
Commanded
Response time of valve movement
Time under calculation with valve position

Tank outlet coolant temperature detection 
The monitor will run whenever the following DTCs are not present
None
Coolant heat storage system malfunction
Not detected
Battery voltage
10 V or more
System status
During recovering
CHS tank outlet temperature difference between preheating start and engine start
20°C (36°F) or more
Difference between engine coolant temperature and CHS tank outlet temperature
More than 30°C (54°F)

TYPICAL MALFUNCTION THRESHOLDS


Potentiometer detection 
Either of the following conditions is met:
(a) or (b)
(a) Potentiometer output difference [D divided by C]
C: Difference between previous and current target
D: Difference between potentiometer output and previous target
10% or more
(b) Potentiometer output deviation from target
0.1 V or more

Tank outlet coolant temperature detection 
Either of the following conditions is met:
(a) or (b)
(a) Heat storage tank outlet coolant temperature when recover starts
60°C (140°F) or more
(b) Heat storage tank outlet coolant temperature difference during water valve check
Less than 3°C (5.4°F)

WIRING DIAGRAM

Refer to DTC P1120 .

INSPECTION PROCEDURE

HINT:
  1. Although each DTC title says "Coolant Flow Control Valve", these DTCs are related to the water valve.
  2. CHS stands for Coolant Heat Storage.

CAUTION:
Be careful when replacing any part in the system or changing the coolant because the coolant in the heat storage tank is hot even if the engine is cold.

HINT:
  1. If DTCs P1121 and P1150 are detected simultaneously, there may be malfunction in the water valve system.
  2. If DTC P1121 is detected, coolant passages may be clogged.
  3. To check the coolant heat storage (CHS) system, the ECM may cause the water pump of the CHS system to operate 5 hours after the power switch has been turned OFF.
  4. Read freeze frame data using Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air/fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.CHECK OTHER DTC OUTPUT (IN ADDITION TO DTC P1121)
  1. Connect Techstream to the DLC3.

  1. Turn the power switch ON (IG).

  1. Turn the tester ON.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Code.

  1. Read DTCs.

    Result:
    Display (DTC Output)
    Proceed to
    P1121
    A
    P1121 and other DTCs
    B

    HINT:
    If any other codes besides P1121 are output, perform troubleshooting for those DTCs first.



B
GO TO DTC CHART
A


2.PERFORM ACTIVE TEST BY TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the power switch ON (IG).

  1. Turn the tester ON.

  1. Put the engine in inspection mode (Click here).

  1. Start the engine and warm it up.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the Water Flow Valve 3, Activate the Water Flow Valve 4 or Activate the Water Flow Valve 5.

  1. Measure the voltage between terminals WBAD and E2 of the ECM connector.

    Standard voltage:
    Tester Operation
    Specified Condition
    "Water Flow Valve 3" ON
    Approximately 2.5 V
    "Water Flow Valve 4" ON
    Approximately 3.5 V
    "Water Flow Valve 5" ON
    Approximately 4.5 V



NG
REPLACE WATER W/BRACKET VALVE ASSEMBLY
OK


3.CHECK COOLING SYSTEM (CHECK FOR CLOGGING IN THE COOLANT SYSTEM)

OK:
Coolant passages are not clogged.



NG
REPAIR OR REPLACE COOLING SYSTEM
OK

REPLACE ECM