BATTERY BLOWER > ON-VEHICLE INSPECTION |
| 1. INSPECT BATTERY BLOWER |
Check the operation.
Connect the Techstream to the DLC3.
Turn the power switch ON (IG).
Select the item:
Powertrain / HV Battery / Active Test / Cooling Fan Spd / 1 to 6.
Inspect the resistance.
Remove the service plug grip (Click here).
Disconnect the connector of the battery blower motor.
![]() |
Measure the resistance between terminals 1 and 2 of the connector.
![]() |
Inspect the voltage.
Connect the connector of the blower motor.
Measure the resistance between terminal 1 (GND) of the blower motor control connector and body ground.
Connect the negative terminal of the auxiliary battery.
Connect the Techstream to the DLC3.
Turn the power switch ON (IG).
Select the item:
Powertrain / HV Battery / Active Test / Cooling Fan Spd / 1.
![]() |
Measure the voltage between terminals 1 (GND) of the blower motor connector and the body ground.
Turn the power switch OFF, then disconnect the cable from the negative terminal of the auxiliary battery.
Disconnect the battery blower motor, battery blower motor control, and connector of the battery ECU.

Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| B9-1 - B10-4 (VM) | Below 1 Ω |
| B9-1 - B11-9 (VM) | Below 1 Ω |
| B9-1 - Body ground | 10 kΩ or higher |
Measure the resistance of the wire harness side connectors.

| Tester Connection | Specified Condition |
| B14-2 - B11-10 (FCTL1) | Below 1 Ω |
| B14-2 - Body ground | 10 kΩ or higher |
Reconnect all the disconnected connectors.
Connect the Techstream to the DLC3.
Turn the power switch ON (IG).
Select the item:
Powertrain / HV Battery / Active Test / Cooling Fan Spd / 1.
![]() |
Measure the voltage between terminals 1 (GND) and 2 (SI) of the battery blower motor control.
![]() |
Measure the voltage between the terminals on the blower motor connector.
![]() |
Measure the voltage between terminals 1 (GND) and 4 (VM) of the blower motor control.
Recheck the blower motor operation by the Techstream, and perform the inspection again.