Home › HYBRID SYSTEM › P112 HYBRID BATTERY CONTROL › BATTERY BLOWER

BATTERY BLOWER > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT BATTERY BLOWER
  1. Check the operation.

    1. Connect the Techstream to the DLC3.

    2. Turn the power switch ON (IG).

    3. Select the item:
      Powertrain / HV Battery / Active Test / Cooling Fan Spd / 1 to 6.

      NOTICE:
      If the check results are normal, do not perform the following check.



  1. Inspect the resistance.

    1. Remove the service plug grip (Click here).

    2. Disconnect the connector of the battery blower motor.



    3. A090450E01
    4. Measure the resistance between terminals 1 and 2 of the connector.

      Standard resistance:
      9 Ω or less

      If the result is not as specified, replace the battery blower assembly.



    A077570E02
  1. Inspect the voltage.

    1. Connect the connector of the blower motor.

    2. Measure the resistance between terminal 1 (GND) of the blower motor control connector and body ground.

      Standard resistance:
      1 Ω or less

    3. Connect the negative terminal of the auxiliary battery.

      Torque:
      6.0 N*m{ 61 kgf*cm , 53 in.*lbf }

    4. Connect the Techstream to the DLC3.

    5. Turn the power switch ON (IG).

    6. Select the item:
      Powertrain / HV Battery / Active Test / Cooling Fan Spd / 1.



    7. A088189E01
    8. Measure the voltage between terminals 1 (GND) of the blower motor connector and the body ground.

      Standard voltage:
      9 to 14 V

      NOTICE:
      If there is no voltage, there may be a defect in the power supply system relays or in the wire harness.

    9. Turn the power switch OFF, then disconnect the cable from the negative terminal of the auxiliary battery.



    10. Disconnect the battery blower motor, battery blower motor control, and connector of the battery ECU.


      A125181E02

    11. Measure the resistance of the wire harness side connectors.

      Standard resistance:
      Tester Connection
      Specified Condition
      B9-1 - B10-4 (VM)
      Below 1 Ω
      B9-1 - B11-9 (VM)
      Below 1 Ω
      B9-1 - Body ground
      10 kΩ or higher

      NOTICE:
      If the result is not as specified, repair or replace the wire harness and recheck the blower motor operation by the Techstream.



    12. Measure the resistance of the wire harness side connectors.


      A125182E02

      Standard resistance:
      Tester Connection
      Specified Condition
      B14-2 - B11-10 (FCTL1)
      Below 1 Ω
      B14-2 - Body ground
      10 kΩ or higher

      NOTICE:
      If the result is not as specified, repair or replace the wire harness and recheck the blower motor operation by the Techstream.

    13. Reconnect all the disconnected connectors.

      NOTICE:
      Do not connect the service plug grip.

    14. Connect the Techstream to the DLC3.

    15. Turn the power switch ON (IG).

    16. Select the item:
      Powertrain / HV Battery / Active Test / Cooling Fan Spd / 1.



    17. A077572E01
    18. Measure the voltage between terminals 1 (GND) and 2 (SI) of the battery blower motor control.

      Standard voltage:
      1 V or more

      NOTICE:
      If the result is not as specified, repair or replace the wire harness and recheck the blower motor operation by the Techstream.



    19. A088189E01
    20. Measure the voltage between the terminals on the blower motor connector.

      Standard voltage:
      2 to 4 V

      NOTICE:
      If the result is not as specified, repair or replace the wire harness and recheck the blower motor operation by the Techstream.



    21. A077572E02
    22. Measure the voltage between terminals 1 (GND) and 4 (VM) of the blower motor control.

      HINT:
      A = (Measured voltage between terminals 1 (GND) of the blower motor connector and the body ground.)

      Standard condition:
      A - 4 V to A - 2 V

      NOTICE:
      If the result is not as specified, repair or replace the wire harness and recheck the blower motor operation by the Techstream.

    23. Recheck the blower motor operation by the Techstream, and perform the inspection again.