Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › 2011.12–2014.12
NM2170E _58 Vehicle Interior _056990 HEATING / AIR CONDITIONING _0277789 AIR CONDITIONING SYSTEM UN GENERAL/CONTROL/DETAILS F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  GENERAL/CONTROL/DETAILS  DETAILS  


FUNCTION OF MAIN COMPONENTS


a.

The air conditioning system consists of the following parts:

Component Function
Air Conditioning Control Assembly Allows operation and adjustment of the air conditioning system via switches.
Air Conditioning Amplifier Assembly Transmits and receives data between the switches and sensors.
Electric Inverter Compressor (Compressor with Motor Assembly) Performs suction, compression and discharge of refrigerant gas and is driven by the electric motor.
Blower with Fan Motor Assembly High magnetic force magnets and ball bearings are used to achieve a compact and lightweight assembly.
Cooler Condenser Assembly A Multi-Flow (MF)-IV sub-cool condenser is used to improve heat exchange efficiency.
Heater Radiator Unit Sub-assembly A Straight Flow Aluminum (SFA)-II heater radiator is used for compactness and high performance.
No. 1 Cooler Evaporator Sub-assembly A Beneficial Refrigerant Stream (BRS) evaporator is used for compactness.
No. 1 Cooler Thermistor Detects the temperature of the fin surface of the No. 1 cooler evaporator sub-assembly and transmits the data to the air conditioning amplifier assembly.
Thermistor Assembly Detects ambient temperature and outputs it to the air conditioning amplifier assembly.
Cooler (Room Temperature Sensor) Thermistor Detects room temperature and outputs it to the air conditioning amplifier assembly.
Cooler (Solar Sensor) Thermistor Detects the changes in the amount of solar energy and outputs them to the air conditioning amplifier assembly.
Air Mix Servo Motor (No. 1 Air Conditioning Radiator Damper Servo Sub-assembly) Receives the input of temperature setting signals via the air conditioning amplifier assembly, operates the motor, and opens and closes the air mix damper.
Air Inlet Servo Motor (No. 1 Blower Damper Servo Sub-assembly) Receives the input of the operation signals from the fresh-air/recirculation selector switch via the air conditioning amplifier assembly, operates the motor, and opens and closes the fresh-air/recirculation damper.
Air Outlet Servo Motor (No. 2 Air Conditioning Radiator Damper Servo Sub-assembly) Receives the input of the operation signals from the mode selector switch via the air conditioning amplifier assembly, operates the motor, and opens and closes the mode damper.
Air Refiner Element Removes pollen and other particles to provide a comfortable interior space.
Air Conditioning Pressure Sensor Detects the refrigerant pressure and sends the data to the air conditioning amplifier assembly.
ECM Receives the signals from the E.F.I. engine coolant temperature sensor and transmits them to the air conditioning amplifier assembly.
Combination Meter Assembly Transmits the vehicle speed signal to the air conditioning amplifier assembly.
Inverter with Converter Assembly Transmits the power control unit state signal to the air conditioning amplifier assembly.
Steering Pad Switch Assembly Sends the steering pad switch operation signal to the air conditioning control assembly.
ECO MODE Switch (Eco Switch Assembly) Sends the ECO MODE switch operation signal to the air conditioning amplifier assembly.



SYSTEM CONTROL


a.

Control List

i.

The air conditioning system uses the following types of control.

Control Outline
Neural Network Control This control is capable of effecting complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input or output relationship that is similar to a human brain.
Outlet Air Temperature Control In compliance with the temperature set at the temperature control switch, the neural network control calculates the outlet temperature based on the input signals from various sensors. In addition, corrections in accordance with the signals from the No. 1 cooler thermistor and the E.F.I. engine coolant temperature sensor are added to control the outlet air temperature.
Blower Control Controls the blower with fan motor sub-assembly in accordance with the airflow volume that has been calculated by the neural network control based on the input signals from various sensors.
Air Outlet Control Automatically switches the outlets in accordance with the outlet mode ratio that has been calculated by the neural network control based on the input signals from various sensors.
Air Inlet Control Automatically controls the air inlet control damper in accordance with the airflow volume that has been calculated by the neural network control.
Electric Inverter Compressor Control Compressor Speed Control The air conditioning amplifier assembly calculates the target speed of the compressor based on the target evaporator temperature (which is calculated by the temperature control switch, cooler (room temperature sensor) thermistor, thermistor assembly and cooler thermistor) and the actual evaporator temperature that is detected by the No. 1 cooler thermistor in order to control the compressor speed.
The air conditioning amplifier assembly calculates the target evaporator temperature, which includes corrections based on the temperature control switch, cooler (room temperature sensor) thermistor, thermistor assembly, cooler thermistor and No. 1 cooler thermistor. Accordingly, the air conditioning amplifier assembly controls the compressor speed to an extent that would not inhibit the proper cooling performance or defogging performance.
Refrigerant Volume Detection Control Judges a shortage of refrigerant volume based on signals from each sensor and informs the user by turning off the indicator light of the A/C switch.
Electric Water Pump Control The air conditioning amplifier assembly calculates the flow rate value required for the engine water pump assembly in accordance with the engine coolant temperature and air mix damper opening degree and sends it to the ECM.
Eco Drive Mode Control When the ECO MODE switch (eco switch assembly) is turned on, the air conditioning amplifier assembly limits the air conditioning system performance.
Rear Window Defogger Control When the hybrid system is operating (READY), and the rear defogger switch is pushed, this system is activated to keep the defogger heater on for approximately 15 minutes.
Self-diagnosis The air conditioning amplifier assembly has a self-diagnosis function. It stores any operation failures in the memory in the form of a Diagnostic Trouble Code (DTC).



b.

Neural Network Control

i.

Previously, in automatic air conditioning systems without neural network control, the air conditioning amplifier assembly determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors. However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for effecting a higher level of control, a neural network has been adopted in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier assembly. The air conditioning amplifier assembly can then effect control to provide enhanced air conditioning comfort.


ii.

The neural network control consists of neurons in the input layer, intermediate layer and output layer. The input layer neurons process the input data of the ambient temperature, the amount of sunlight, and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume and outlet mode control volume. Accordingly, the air conditioning amplifier assembly controls the servo motors and blower motor in accordance with the control volumes that have been calculated by the neural network control.

Y113849E03
2.823,0.135 4,0.333 1.177,0.198 10 false Intermediate Layer 4.229,0.76 5.938,1.073 1.708,0.313 10 false Target Output Temperature 2.063,3.667 2.906,4.042 0.844,0.375 10 false Target Outlet Temperature 1.354,1.302 2.583,1.5 1.229,0.198 10 false Amount of Sunlight 2.083,6.323 2.917,6.531 0.833,0.208 10 false Outlet Mode 0.208,6.927 1.104,7.156 0.896,0.229 10 false Sensor Input 0.208,8.073 1.063,8.26 0.854,0.188 10 false Switch Input 0.469,9.531 2.625,9.729 2.156,0.198 10 false : Neural network operation range 2.073,7.427 2.854,7.625 0.781,0.198 10 false Inlet Mode 2.073,8.656 2.948,8.865 0.875,0.208 10 false Compressor 2.031,4.406 3.24,4.938 1.208,0.531 10 false Amount of Sunlight Correction 0.219,5.094 1.01,5.552 0.792,0.458 10 false Temperature Setting 3.573,3.823 4.573,4.438 1,0.615 10 false Temperature Control Correction 3.625,7.25 4.542,7.677 0.917,0.427 10 false Various Types of Corrections 3.615,6.188 4.531,6.625 0.917,0.438 10 false Various Types of Corrections 3.563,5 4.594,5.615 1.031,0.615 10 false Various Types of Airflow Volume Corrections 2.104,2.781 2.625,3 0.521,0.219 10 false Control 0.219,3.594 1.281,3.844 1.063,0.25 10 false Input Processing 2.052,3.208 3.24,3.458 1.188,0.25 10 false Neural Networking 4.99,3.302 6.229,3.552 1.24,0.25 10 false Output Processing 1.229,0.771 2.583,1 1.354,0.229 10 false Ambient Temperature 2.073,5.167 2.948,5.552 0.875,0.385 10 false Target Airflow Volume 2,0.396 2.75,0.583 0.75,0.188 10 false Input Layer 3.969,0.396 4.833,0.583 0.865,0.188 10 false Output Layer 5,5.021 6.417,5.406 1.417,0.385 10 false Blower with Fan Motor Sub-assembly 4.979,3.823 6.854,4.406 1.875,0.583 10 false Air Mix Servo Motor (No. 1 Air Conditioning Radiator Damper Servo Sub-assembly) 4.99,7.052 6.667,7.604 1.677,0.552 10 false Air Inlet Servo Motor (No. 1 Blower Damper Servo Sub-assembly) 4.979,5.885 6.823,6.469 1.844,0.583 10 false Air Outlet Servo Motor (No. 2 Air Conditioning Radiator Damper Servo Sub-assembly) 5.01,8.271 6.76,8.823 1.75,0.552 10 false Electric Inverter Compressor (Compressor with Motor Assembly)



c.

Electric Inverter Compressor Control

i.

The air conditioning amplifier assembly calculates the target compressor speed based on the target evaporator temperature (calculated from the temperature control switch, cooler (room temperature sensor) thermistor, thermistor assembly and cooler thermistor) and the actual evaporator temperature detected by the No. 1 cooler thermistor. Then, the air conditioning amplifier assembly transmits the target speed to the power management control ECU. The power management control ECU controls the air conditioning inverter based on the target speed data in order to control the electric inverter compressor (compressor with motor assembly) to a speed that suits the operating condition of the air conditioning system.


ii.

The air conditioning amplifier assembly calculates the target evaporator temperature, which includes corrections based on the temperature control switch, cooler (room temperature sensor) thermistor, thermistor assembly, cooler thermistor and No. 1 cooler thermistor. Accordingly, the air conditioning amplifier assembly controls the compressor speed to an extent that does not inhibit the proper cooling performance or defogging performance. As a result, comfort and low fuel consumption can be realized.


iii.

The electric inverter compressor (compressor with motor assembly) is supplied with high-voltage direct current, and it uses high-voltage alternating current internally. If an open or short circuit occurs in the electric inverter compressor (compressor with motor assembly), the power management control ECU will cut off the air conditioning inverter circuit.

Y113850E05
5.302,0.875 6.563,1.229 1.26,0.354 10 false Power Management Control ECU 5.281,2.573 6.906,3.229 1.625,0.656 10 false Electric Inverter Compressor (Compressor with Motor Assembly) 5.344,3.76 6.854,3.979 1.51,0.219 10 false Air Conditioning Inverter 4.302,0.833 5.177,1.052 0.875,0.219 10 false CAN (V Bus) 6.167,1.698 6.667,2.115 0.5,0.417 10 false Inverter Control 2.573,1 4.146,1.375 1.573,0.375 10 false Air Conditioning Amplifier Assembly 2.615,2.24 4.073,3.583 1.458,1.344 10 false Calculates the target compressor speed in accordance with various input conditions. 4.229,1.448 5.438,1.833 1.208,0.385 10 false Target Compressor Speed 0.188,0.167 2,0.365 1.813,0.198 10 false Temperature Control Switch 0.177,1.042 1.844,1.438 1.667,0.396 10 false Cooler (Room Temperature Sensor) Thermistor 0.167,2.24 1.604,2.448 1.438,0.208 10 false Thermistor Assembly 0.188,3.104 1.594,3.563 1.406,0.458 10 false Cooler (Solar Sensor) Thermistor 0.198,4.292 1.781,4.49 1.583,0.198 10 false No. 1 Cooler Thermistor



d.

Refrigerant Volume Detection Control

i.

The air conditioning amplifier assembly judges the volume of refrigerant from the ambient temperature, refrigerant pressure and the temperature of the cool air past the No. 1 cooler evaporator sub-assembly. When the air conditioning amplifier assembly judges refrigerant shortage, it turns off the indicator light of the A/C switch. At that time, the electric inverter compressor (compressor with motor assembly) stops operating.

Y113851E05
2.563,1.969 4.125,2.385 1.563,0.417 10 false Air Conditioning Amplifier Assembly 0.177,0.281 1.781,0.667 1.604,0.385 10 false Air Conditioning Pressure Sensor 0.188,0.958 2,1.177 1.813,0.219 10 false - Refrigerant Pressure Signal 0.198,2.146 1.792,2.323 1.594,0.177 10 false No. 1 Cooler Thermistor 0.177,2.469 1.76,2.677 1.583,0.208 10 false - Air Temperature Signal 0.198,3.646 1.573,3.854 1.375,0.208 10 false Thermistor Assembly 0.177,3.979 2.073,4.177 1.896,0.198 10 false - Ambient Temperature Signal 5.188,0.208 6.677,0.583 1.49,0.375 10 false Air Conditioning Control Assembly 5.26,1.031 6.01,1.24 0.75,0.208 10 false A/C Switch 5.333,1.375 6.313,1.594 0.979,0.219 10 false Indicator Light 5.188,3.354 6.823,4.083 1.635,0.729 10 false Electric Inverter Compressor (Compressor with Motor Assembly) 5.198,2.313 6.458,2.677 1.26,0.365 10 false Power Management Control ECU 4.229,2.719 5.083,2.958 0.854,0.24 10 false CAN (V Bus) 4.542,1.646 4.833,1.823 0.292,0.177 10 false LIN



e.

Eco Drive Mode Control

i.

During eco drive mode control, the air conditioning amplifier assembly restricts the air conditioning system performance under specified conditions, thus improving fuel economy.


ii.

Eco drive mode control is activated when the ECO MODE switch (eco switch assembly) is pressed, and then restricts the air conditioning system performance as described below.

Control Outline
Inside/Outside Air Switch Control Automatically switches the air inlet port to recirculation mode when the outside air temperature is equal to or higher than a predetermined temperature and reduces the power consumption.
Blower Level Control Sets the blower level in AUTO mode lower than normal, and suppresses the power consumption.
Heating Restriction Control Changes the air outlet temperature by entering eco drive mode during heating and increases the amount of engine-off time when the drive mode is in ECO, thus improving fuel economy.
Compressor Speed Restriction Control Restricts the maximum compressor speed during cooling and reduces the power consumption.




CONSTRUCTION


a.

Air Conditioning Control Assembly

i.

The push button and dial type air conditioning control assembly is used.


ii.

The air conditioning control assembly with Liquid Crystal Display (LCD) is used to ensure excellent visibility.

Y113852E02
3.771,0.313 3.771,0.573 true 3.688,0.135 3.99,0.344 0.302,0.208 10 false *1

Text in Illustration
*1 LCD - -



b.

Air Conditioning Unit Assembly

i.

The air conditioning unit consists of the heater radiator unit sub-assembly, No. 1 cooler evaporator sub-assembly, No. 1 cooler thermistor and damper servo sub-assemblies.


ii.

A semi-center location air conditioning unit, in which the heater radiator unit sub-assembly and No. 1 cooler evaporator sub-assembly are placed in the vehicle's longitudinal direction, is used.

Y113853E03
0.688,1.813 1.458,1.813 true 3.823,1.813 4.438,1.813 true 3.813,2.281 4.427,2.281 true 1.708,2.385 1.708,3.063 true 0.521,1.708 0.823,1.917 0.302,0.208 10 false *2 3.656,1.729 3.958,1.938 0.302,0.208 10 false *2 3.656,2.198 3.958,2.406 0.302,0.208 10 false *1 1.646,3.063 1.948,3.271 0.302,0.208 10 false *1 0.344,0.51 0.646,0.719 0.302,0.208 10 false *a 3.458,0.51 3.76,0.719 0.302,0.208 10 false *b

Text in Illustration
*1 No. 1 Cooler Evaporator Sub-assembly *2 Heater Radiator Unit Sub-assembly
*a Side View *b Top View
V100135

Front - -


iii.

A partial recirculation system is used. This system has an air inlet control door (sub) in the air inlet duct. Thus, it is able to cycle a small volume of recirculated air even in the FRESH mode, thus enhancing heating performance. When the blower switch is on, the suction force of the blower fan opens this air inlet control door (sub).

Y113854E03
4.823,2.667 4.25,4.302 4.25,4.302 3.917,4.302 true 2.323,2.063 2.323,1.583 2.323,1.583 2.896,1.583 true 1.625,1.063 1.344,0.344 1.344,0.344 1.063,0.344 true 1.01,2.198 0.677,2.51 0.677,2.51 0.583,2.51 true 2.917,1.469 3.208,1.708 0.292,0.24 10 false *1 3.75,4.219 4.042,4.458 0.292,0.24 10 false *1 0.885,0.25 1.177,0.49 0.292,0.24 10 false *2 0.417,2.438 0.708,2.677 0.292,0.24 10 false *3 1.042,0.823 1.333,1.063 0.292,0.24 10 false *a 2.844,1.906 3.135,2.146 0.292,0.24 10 false *a 2.365,0.677 2.656,0.917 0.292,0.24 10 false *b 1.635,3.073 1.927,3.313 0.292,0.24 10 false *c

Text in Illustration
*1 Air Inlet Control Door (Sub) *2 Air Inlet Control Door
*3 Air Inlet Duct - -
*a RECIRC *b FRESH
*c To Blower Fan - -
V100135

Air Flow
V100136

Front



c.

No. 1 Cooler Evaporator Sub-assembly

i.

A Beneficial Refrigerant Stream (BRS) type No. 1 cooler evaporator sub-assembly is used.


ii.

By placing the tanks at the top and the bottom of the No. 1 cooler evaporator sub-assembly and by using a micropore tube construction, the following effects have been achieved:

·

Heat exchanging efficiency is ensured.

·

Temperature distribution is made uniform.

·

The No. 1 cooler evaporator sub-assembly is made thinner.



iii.

The internal path of the No. 1 cooler evaporator sub-assembly where refrigerant flows through has been optimized to reduce the refrigerant pressure loss, enhancing the performance and downsizing the evaporator.

Y113855E03
2.979,2.802 2.979,3.26 true 1.583,0.938 1.583,1.396 true 5.365,0.896 5.365,1.229 true 5.281,2.083 5.281,2.448 true 2.927,3.271 3.219,3.51 0.292,0.24 10 false *1 5.302,0.729 5.594,0.969 0.292,0.24 10 false *2 5.229,2.458 5.521,2.698 0.292,0.24 10 false *3 1.51,0.75 1.802,0.99 0.292,0.24 10 false *1

Text in Illustration
*1 Tank *2 Micropore Tube
*3 Cooling Fin - -


iv.

The refrigerant exchanges heat by flowing through the tubes inside the No. 1 cooler evaporator sub-assembly, and it will vaporize to gas.


v.

The ratio of tubes, through which the refrigerant flows, has been increased in the turn areas, so that the refrigerant can flow smoother and more efficiently, resulting pressure loss reduction.

Y113856E03
1.115,1.458 1.354,1.75 0.24,0.292 10 false In 5.594,1.573 5.896,1.865 0.302,0.292 10 false Out 5.583,3 5.885,3.292 0.302,0.292 10 false Out 1.115,2.896 1.354,3.188 0.24,0.292 10 false In 0.198,1.656 0.917,1.896 0.719,0.24 10 false BRS Type 0.146,3.021 0.979,3.406 0.833,0.385 10 false Conventional Type 1.281,0.74 2.313,0.979 1.031,0.24 10 false 1st Turn (Block) 2.771,0.74 3.875,0.969 1.104,0.229 10 false 2nd Turn (Block) 4.271,0.75 5.375,0.969 1.104,0.219 10 false 3rd Turn (Block) 5.823,0.74 6.906,0.979 1.083,0.24 10 false 4th Turn (Block) 0.5,4.156 3.448,4.542 2.948,0.385 10 false : Flow of the refrigerant



d.

No. 1 Cooler Thermistor

i.

The No. 1 cooler thermistor detects the temperature of the cool air immediately past the No. 1 cooler evaporator sub-assembly in the form of resistance changes, and outputs it to the air conditioning amplifier assembly.



e.

Heater Radiator Unit Sub-assembly

i.

The heater radiator unit sub-assembly has been made more compact and performance has been improved by making the core section finer and improving the shapes of the tank section and flow section. Also, the environment has been considered. By using aluminum as the material, the amount of the environmental burden disposal (lead) has been reduced.

Y113857



f.

Blower with Fan Motor Sub-assembly

i.

High magnetic force magnets and ball bearings are used to achieve a compact and lightweight assembly.



g.

Bus Connector (Air Conditioning Harness Assembly)

i.

The bus connector (air conditioning harness assembly) has a built-in communication/driver IC, which communicates with each servo motor connector, actuates the servo motor, and has a position detection function. This enables bus communication for the servo motor wire harness to achieve a more lightweight construction and a reduced number of wires.

Y111170E14
4.573,1.583 4.573,0.771 4.573,0.771 4.74,0.771 true 4.688,1.729 4.688,1.219 4.688,1.219 4.854,1.219 true 0.823,0.979 3.083,1.229 2.26,0.25 10 false Air Conditioning Amplifier Assembly 1.094,1.719 2.583,1.938 1.49,0.219 10 false Communication Circuit 1.708,2.167 2.104,2.375 0.396,0.208 10 false CPU 4.781,0.677 5.813,0.896 1.031,0.219 10 false Bus Connector 4.885,1.125 6.542,1.354 1.656,0.229 10 false Communication/Driver IC 5.865,3.167 6.667,3.375 0.802,0.208 10 false Servo Motor 4.604,2.24 5.427,2.448 0.823,0.208 10 false Servo Motor



h.

Servo Motor

i.

In contrast to the previous type that detects the position by way of a potentiometer voltage, the pulse pattern type servo motor detects the relative position by way of the 2-bit on/off signals.


ii.

The forward and reverse revolutions of this motor are detected by way of 2 phases, A and B, which output 4 types of patterns. The air conditioning amplifier assembly counts the number of pulse patterns in order to determine the stopped position.

Y100716E31
3.99,2.385 3.719,2.385 3.719,2.385 3.5,2.781 true 3.094,1.885 2.792,1.885 2.792,1.885 2.875,2.865 false 3.938,2.875 4.396,2.875 true 4.104,3.135 4.271,3.344 4.271,3.344 4.417,3.344 true 3.25,4.594 3.396,4.354 3.396,4.354 3.521,4.354 true 2.229,0.531 2.063,0.531 2.063,0.531 1.802,1.115 false 0.156,0.792 0.74,1.042 0.583,0.25 10 false Phase B 0.156,1.146 0.729,1.396 0.573,0.25 10 false Phase A 0.156,1.479 0.792,1.729 0.635,0.25 10 false Common 2.26,0.458 3.5,0.844 1.24,0.385 10 false Rotational Direction of Printed Board 2.26,1.417 3.219,1.656 0.958,0.24 10 false Pattern Width 4.906,0.917 5.656,1.094 0.75,0.177 10 false Phase A: + 4.667,1.323 5.667,1.5 1,0.177 10 false Common: GND 4.917,1.74 5.656,1.917 0.74,0.177 10 false Phase B: + 4.021,2.302 6.354,2.521 2.333,0.219 10 false Rotational Direction of Printed Board 3.135,1.802 4.427,2.021 1.292,0.219 10 false Fixed Contact Point 4.438,2.781 5.51,2.979 1.073,0.198 10 false Printed Board 4.448,3.25 5.021,3.427 0.573,0.177 10 false Pattern 3.552,4.26 4.917,4.479 1.365,0.219 10 false Pattern Width 2.81° 2.177,4.052 2.781,4.25 0.604,0.198 10 false Phase B 2.01,3.229 2.781,3.427 0.771,0.198 10 false Pattern No. 2.177,3.563 2.781,3.76 0.604,0.198 10 false Phase A 2.854,3.229 2.99,3.458 0.135,0.229 10 false 1 3.01,3.229 3.146,3.458 0.135,0.229 10 false 2 3.198,3.229 3.333,3.458 0.135,0.229 10 false 3 3.375,3.229 3.51,3.458 0.135,0.229 10 false 4 3.552,3.229 3.688,3.458 0.135,0.229 10 false 1 3.729,3.229 3.865,3.458 0.135,0.229 10 false 2 3.906,3.229 4.042,3.458 0.135,0.229 10 false 3 4.083,3.229 4.219,3.458 0.135,0.229 10 false 4 2.854,3.656 2.99,3.885 0.135,0.229 10 false 1 3.01,3.656 3.146,3.885 0.135,0.229 10 false 1 3.198,3.635 3.333,3.865 0.135,0.229 10 false 0 3.375,3.635 3.51,3.865 0.135,0.229 10 false 0 3.552,3.656 3.688,3.885 0.135,0.229 10 false 1 3.729,3.656 3.865,3.885 0.135,0.229 10 false 1 3.906,3.635 4.042,3.865 0.135,0.229 10 false 0 4.083,3.635 4.219,3.865 0.135,0.229 10 false 0 2.854,3.958 2.99,4.188 0.135,0.229 10 false 0 3.01,3.979 3.146,4.208 0.135,0.229 10 false 1 3.198,3.979 3.333,4.208 0.135,0.229 10 false 1 3.375,3.958 3.51,4.188 0.135,0.229 10 false 0 3.552,3.958 3.688,4.188 0.135,0.229 10 false 0 3.729,3.979 3.865,4.208 0.135,0.229 10 false 1 3.906,3.979 4.042,4.208 0.135,0.229 10 false 1 4.073,3.958 4.208,4.188 0.135,0.229 10 false 0 0.958,2.583 1.708,2.76 0.75,0.177 10 false Phase A: + 0.708,2.979 1.708,3.156 1,0.177 10 false Common: GND 0.979,3.365 1.719,3.542 0.74,0.177 10 false Phase B: +



i.

Cooler Condenser Assembly

i.

A sub-cool condenser is used. This is a multi-flow condenser consisting of 3 portions: a condensing portion, a super-cooling portion and a gas-liquid separator (modulator) all integrated together. This cooler condenser assembly uses a sub-cool cycle for its cooling cycle system to improve heat-exchanging efficiency.


ii.

In the sub-cool cycle, after the refrigerant passes through the condensing portion of the cooler condenser assembly, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the No. 1 cooler evaporator sub-assembly in an almost completely liquefied state.

Y113858E03
3,0.479 3,1 true 4.958,1.271 5.563,1.271 true 6.219,2 6.427,2 true 6.135,2.375 6.427,2.375 true 3.135,2.76 3.135,3.271 true 3.063,3.271 3.354,3.51 0.292,0.24 10 false *4 5.594,1.156 5.885,1.396 0.292,0.24 10 false *1 6.438,1.896 6.729,2.135 0.292,0.24 10 false *2 6.438,2.281 6.729,2.521 0.292,0.24 10 false *3 2.927,0.313 3.219,0.552 0.292,0.24 10 false *5

Text in Illustration
*1 Modulator *2 Desiccant
*3 Filter *4 Super-cooling Portion
*5 Condensing Portion - -
V100135

Gaseous Refrigerant
V100136

Liquid Refrigerant

HINT:

The point at which the air bubbles disappear in the refrigerant of the sub-cool cycle is lower than the proper amount of refrigerant with which the system must be filled. Therefore, if the system were recharged with refrigerant based on the point at which the air bubbles disappear, the amount of refrigerant would be insufficient. As a result, the cooling performance of the system will be affected. If the system is overcharged with refrigerant, this will also lead to reduced performance. For the proper method of verifying the amount of the refrigerant and to recharge the system with refrigerant, refer to the Repair Manual.


Y100720E02
2.5,1.99 3.063,1.99 true 0.583,1.104 1.583,1.354 1,0.25 10 High Pressure 2.479,0.698 4.156,0.948 1.677,0.25 10 Proper Recharged Amount 3.104,1.927 5.208,2.177 2.104,0.25 10 Point at which Bubbles Disappear 4.958,2.323 6.344,2.583 1.385,0.26 10 Amount of Refrigerant



j.

Electric Inverter Compressor (Compressor with Motor Assembly)

i.

An ES14 type electric inverter compressor (compressor with motor assembly) that is driven by a motor is used. The basic construction and operation of this compressor are the same as the ordinary scroll compressor, except that it is driven by an electric motor.


ii.

The electric inverter compressor (compressor with motor assembly) consists of a spirally wound fixed scroll and rotating scroll that form a pair, a brushless motor, an oil separator, a motor shaft and air conditioning inverter.


iii.

The air conditioning inverter is integrated with the electric inverter compressor (compressor with motor assembly). This inverter operates the compressor on the HV battery. As a result, the air conditioning system is actuated without depending on the operation of the engine, thus realizing a comfortable air conditioning system and low fuel consumption.


iv.

The fixed scroll is integrated with the housing. Because the rotation of the shaft causes the rotating scroll to revolve while maintaining the same posture, the volume of the space that is partitioned by both scrolls varies to perform the suction, compression and the discharge of the refrigerant gas. Locating the suction port directly above the scrolls enables direct suction, thus realizing improved suction efficiency. Containing a built-in oil separator, this compressor is able to separate the compressor oil that is intermixed with the refrigerant and circulates in the refrigeration cycle, thus realizing a reduction in the oil circulation rate.


v.

Low-moisture permeation hoses are used for the suction and discharge hoses at the compressor in order to minimize the entry of moisture into the refrigeration cycle.

Y118260E05
3.906,1.865 4.979,1.865 true 3.865,2.094 3.865,2.708 true 4.229,4.135 5.177,4.135 true 1.531,1.635 2.26,1.635 true 2.979,1.385 2.646,0.469 2.646,0.469 2.458,0.469 true 2.844,1.479 2.01,0.656 2.01,0.656 1.844,0.656 true 2.792,1.865 1.74,2.667 1.74,2.667 1.51,2.667 true 2.24,3.563 2.24,3.177 2.24,3.177 1.823,3.177 true 4.25,3.302 4.75,2.833 4.75,2.833 4.99,2.833 true 2.271,0.396 2.448,0.594 0.177,0.198 10 false *1 1.677,0.573 1.896,0.771 0.219,0.198 10 false *2 1.365,1.563 1.573,1.76 0.208,0.198 10 false *3 1.333,2.583 1.521,2.792 0.188,0.208 10 false *4 1.656,3.104 1.844,3.323 0.188,0.219 10 false *8 3.792,2.719 4.063,2.958 0.271,0.24 10 false *5 5,1.771 5.271,2.01 0.271,0.24 10 false *6 5.01,2.74 5.219,2.979 0.208,0.24 10 false *7 5.198,4.042 5.469,4.281 0.271,0.24 10 false *9

Text in Illustration
*1 Rotating Scroll *2 Fixed Scroll
*3 Oil Separator *4 Discharge Port
*5 Brushless Motor *6 Motor Shaft
*7 Air Conditioning Inverter *8 Discharge Hose Port
*9 Suction Hose Port - -

CAUTION:

In order ensure the proper insulation of the internal high-voltage portion of the electric inverter compressor (compressor with motor assembly) and the compressor housing, this model has adopted a compressor oil (ND11) with a high level of insulation performance. Therefore, never use a compressor oil other than the ND11 type compressor oil or its equivalent.




k.

Air Refiner Element

i.

A pollen removal type air refiner element is used to remove dust, pollen, and other micron particles from air entering from outside the vehicle to provide a comfortable cabin of clean air. The air refiner element is installed in the upper section of the blower with fan motor assembly.

Y113859E04
1.552,2.417 1.552,2.885 true 1.542,1.135 1.542,1.5 true 5.875,2.146 5.875,2.75 true 5.417,2.281 5.417,2.729 true 4.99,2.5 4.99,3.219 true 1.469,0.958 1.76,1.198 0.292,0.24 10 false *4 5.813,2.76 6.104,3 0.292,0.24 10 false *1 5.354,2.74 5.646,2.979 0.292,0.24 10 false *2 4.927,3.219 5.219,3.458 0.292,0.24 10 false *3 1.49,2.896 1.781,3.135 0.292,0.24 10 false *5 0.365,0.885 0.656,1.125 0.292,0.24 10 false *a 0.552,1.667 0.844,1.906 0.292,0.24 10 false *b 0.552,2.406 0.844,2.646 0.292,0.24 10 false *c

Text in Illustration
*1 Blower with Fan Motor Assembly *2 Air Refiner Element
*3 Air Filter Case *4 Pollen
*5 Micron Particle - -
*a Image of Air Refiner Element *b Large Foreign Object Filter Layer
*c Electret Layer - -



l.

Thermistor Assembly

i.

The thermistor assembly detects the ambient temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier assembly.



m.

Cooler (Room Temperature Sensor) Thermistor

i.

The cooler (room temperature sensor) thermistor detects the room temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier assembly.



n.

Cooler (Solar Sensor) Thermistor

i.

The cooler (solar sensor) thermistor detects (in the form of changes in the current that flows through the built-in photo diode) the changes in the amount of sunlight and outputs these sunlight strength signals to the air conditioning amplifier assembly.



o.

Air Conditioning Pressure Sensor

i.

The air conditioning pressure sensor detects the refrigerant pressure and outputs it to the air conditioning amplifier assembly in the form of voltage changes.




OPERATION


a.

Mode Position and Door Operation

Y113920E02
4.198,4 4.885,5.188 4.885,5.188 5.031,5.188 true 1.792,4.51 2.156,5.135 2.156,5.135 2.354,5.135 true 4.25,3.063 4.958,1.823 4.958,1.823 5.781,1.823 true 2.135,3 2.323,3.198 0.188,0.198 10 false A 1.073,3.031 1.26,3.229 0.188,0.198 10 false B 3.635,3.198 3.823,3.396 0.188,0.198 10 false C 4.75,3.708 4.938,3.906 0.188,0.198 10 false D 4.073,1.792 4.26,1.99 0.188,0.198 10 false E 3.417,1.76 3.604,1.958 0.188,0.198 10 false F 5.417,2.104 5.604,2.302 0.188,0.198 10 false G 5.667,2.333 5.854,2.531 0.188,0.198 10 false H 5.302,3.198 5.49,3.396 0.188,0.198 10 false I 5.813,1.719 7.083,2.365 1.271,0.646 10 false Heater Radiator Unit Sub-assembly 5.073,5.104 6.552,5.521 1.479,0.417 10 false No. 1 Cooler Evaporator Sub-assembly 2.375,5.052 3.781,5.469 1.406,0.417 10 false Blower with Fan Motor Sub-assembly 0.479,2.323 0.906,2.625 0.427,0.302 10 false Fresh 2.115,2.323 3.021,2.615 0.906,0.292 10 false Recirculation 0.073,3.677 0.979,3.969 0.906,0.292 10 false Recirculation 3.469,0.448 4.5,0.76 1.031,0.313 10 false Center Register 3.479,0.75 4.51,1.063 1.031,0.313 10 false Side Register 6.167,2.979 7.083,3.396 0.917,0.417 10 false Front Footwell Register 2.365,0.135 3.406,0.448 1.042,0.313 10 false Front Defroster 2.365,0.438 3.406,0.75 1.042,0.313 10 false Side Defroster

HINT:

This illustration is a model diagram showing the doors positions in each mode. The parts layout and the number of the doors in the illustration are different from those of the actual system.


Control Damper Operation Position Damper Position Operation
Air Inlet FRESH A Brings in fresh air.
RECIRCULATION B Recirculates internal air.
Air Mix MAX COLD to MAX HOT C to D Varies the mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HOT to COLD.
Mode
Y129010

FACE F, I Air blows out of the center register and side register.
Y129009

BI-LEVEL F, H Air blows out of the center register, side registers, and front footwell register ducts.
Y129008

FOOT E, G Air blows out of the front footwell register ducts and side register. In addition, air blows out slightly from the front defroster and side defroster.
Y129007

FOOT/DEF E, H Defrosts the windshield through the front defroster, side defroster and side register, while air is also blown out from the front footwell register ducts.
Y129006

DEF E, I Defrosts the windshield through the front defroster, side defroster and side register.


b.

Air Outlets and Airflow Volume

Y113921E02
3.99,1.771 4.208,1.979 0.219,0.208 10 false A 4.458,1.656 4.677,1.865 0.219,0.208 10 false A 2.615,2.323 2.833,2.531 0.219,0.208 10 false B 5.656,1.427 5.875,1.635 0.219,0.208 10 false B 2.813,3.198 3.031,3.406 0.219,0.208 10 false C 4.333,2.906 4.552,3.115 0.219,0.208 10 false C 1.49,1.479 1.708,1.688 0.219,0.208 10 false D 5.25,0.417 5.469,0.625 0.219,0.208 10 false D 3.458,0.469 3.677,0.677 0.219,0.208 10 false D 2.458,0.698 2.677,0.906 0.219,0.208 10 false D

Indication Mode A B C D
Center Side Foot Defroster
Y129010

FACE
Y129016

Y129016

- -
Y129009

BI-LEVEL
Y129013

Y129013

Y129016

-
Y129008

FOOT -
Y129014

Y129016

Y129014

Y129007

FOOT/DEF -
Y129014

Y129013

Y129014

Y129006

DEF -
Y129016

-
Y129016


HINT:

The size of the circle ○ indicates the proportion of airflow volume.



c.

Compressor Operation

i.

The electric inverter compressor (compressor with motor assembly) performs suction, compression and discharge of refrigerant gas as described in the table below.

Stroke Operation
Suction As the capacity of the compression chamber, which is created between the rotating scroll and the fixed scroll, increases in accordance with the revolution of the rotating scroll, refrigerant gas is drawn in from the intake port.
Compression From the state at which the suction process has been completed, as the revolution of the rotating scroll advances further, the capacity of the compression chamber decreases gradually. Consequently, the refrigerant gas that has been drawn in becomes compressed gradually and is sent to the center of the fixed scroll. The compression of the refrigerant gas is completed when the rotating scroll completes approximately 2 revolutions.
Discharge When the compression of the refrigerant gas is completed and the refrigerant pressure becomes high, the refrigerant gas discharges through the discharge port located in the center of the fixed scroll by pushing the discharge valve.

Y102836E09
2.333,0.885 2.479,0.719 2.479,0.719 2.583,0.719 true 1.99,1.188 1.448,0.677 1.448,0.677 1.01,0.677 true 2.219,1.365 2.469,1.583 2.469,1.583 2.583,1.583 true 1.781,1.365 1.521,1.583 1.521,1.583 0.979,1.583 true 0.042,0.594 0.99,0.844 0.948,0.25 10 false Discharge Port 0.042,1.5 0.958,1.823 0.917,0.323 10 false Rotating Scroll 2.323,0.302 2.896,0.604 0.573,0.302 10 false Suction 2.615,0.615 3.354,0.917 0.74,0.302 10 false Intake Port 2.615,1.5 3.396,1.802 0.781,0.302 10 false Fixed Scroll 6.167,2.802 7.115,3.104 0.948,0.302 10 false Compression 1.042,3.573 1.75,3.875 0.708,0.302 10 false Discharge




DIAGNOSIS


a.

The air conditioning amplifier assembly has a self-diagnosis function. It stores any operation failures in the air conditioning system memory in the form of Diagnostic Trouble Codes (DTCs). For details, refer to the Repair Manual.