OUTLINE
An automatic air conditioning system is used.
The air conditioning system main components have been made compact, lightweight, and highly efficient to achieve both comfort and good fuel economy at the same time.
The Beneficial Refrigerant Stream (BRS) type No. 1 cooler evaporator sub-assembly, which is beneficial to the reduction of pressure loss, has been provided.
SPECIFICATION
Performance
| Item | Specification | ||
|---|---|---|---|
| Heater | Heater Output | W | 4600* |
| Air Flow Volume | m3/h | 280 | |
| Power Consumption | W | 190 | |
| Cooler | Cooling Capacity | W | 4800 |
| Air Flow Volume | m3/h | 475 | |
| Power Consumption | W | 220 | |
*: Except for the heater output of the PTC heater (quick heater assembly)
Ventilation and Heater Radiator Unit Sub-assembly
| Item | Specification | ||
|---|---|---|---|
| Heater Radiator Unit Sub-assembly | Type | Straight Flow Aluminum (SFA)-II | |
| Size: W x H x L | mm (in.) | 201.5 x 120 x 27 (7.9 x 4.7 x 1.1) | |
| Fin Pitch | mm (in.) | 1.8 (0.07) | |
| Blower with Fan Motor Sub-assembly | Motor Type | K62-12.5T | |
| Fan Type | Sirocco | ||
| Fan Size: Dia. x H | mm (in.) | 145 x 65 (5.7 x 2.6) | |
Air Conditioning
| Item | Specification | ||
|---|---|---|---|
| Cooler Condenser Assembly | Type | Multi-Flow (MF)-IV (Sub Cool) | |
| Size: W x H x L | mm (in.) | 620 x 357.4 x 16 (24.4 x 14.1 x 0.6) | |
| Fin Pitch | mm (in.) | 3.15 (0.1) | |
| No. 1 Cooler Evaporator Sub-assembly | Type | Beneficial Refrigerant Stream (BRS) | |
| Size: W x H x L | mm (in.) | 199.3 x 231 x 38 (7.8 x 9.1 x 1.5) | |
| Fin Pitch | mm (in.) | 3.0 (0.1) | |
| Electric Inverter Compressor (Compressor with Motor Assembly) | Type | ES14 | |
| Compressor Oil Type | ND11 | ||
| Refrigerant | Type | HFC134a | |
| Charge Volume | g | 420+/-30 | |
| Air Refiner Element | Pollen Removal Type | ||
MAIN FEATURES
The air conditioning system has the following features:
| Item | Outline |
|---|---|
|
*: Cold area specification models |
|
| High Performance | ·
Neural network control is used so passengers can control the air conditioning accurately for maximum comfort. ·
A pollen removal type air refiner element is used as clean air filter. ·
The blower control has 7 levels in manual mode and 31 levels in auto mode for more precise control. ·
The Positive Temperature Coefficient (PTC) heater control is used. This system contains a PTC heater (quick heater assembly) that heats the air that has passed through the heater radiator unit sub-assembly to ensure proper heater performance.* ·
An exhaust heat recirculation system is used to improve the heating performance at low temperatures. For details about the exhaust heat recirculation system, see the Exhaust System in the 1NZ-FXE INTAKE/EXHAUST section.* |
| Lightweight | A bus connector (air conditioning harness assembly) with a built-in IC is used in a lightweight wire harness design with a reduced number of wires. The use of this connector means that pulse pattern type servo motors are used. |
| Compact | ·
A semi-center location air conditioning unit in which the No. 1 cooler evaporator sub-assembly, heater radiator unit sub-assembly and PTC heater (quick heater assembly)* are placed in the vehicle's longitudinal direction is used. ·
A blower motor with a built-in blower motor controller is used in a compact construction. |
| Others | The following parts are used to ensure high cooling or heating performance while realizing a compact and lightweight construction. -
Beneficial Refrigerant Stream (BRS) type No. 1 cooler evaporator sub-assembly -
Straight Flow Aluminum (SFA)-II type heater radiator unit sub-assembly -
Multi-Flow (MF)-IV type cooler condenser assembly -
ES14 type electric inverter compressor (compressor with motor assembly) |