Home › General › SPECIFICATIONS › 1NZ-FXE BATTERY / CHARGING › 2011.12–2017.06
RM2170E _V1 General _057001 SPECIFICATIONS _0277881 1NZ-FXE BATTERY / CHARGING F

SPECIFICATIONS  1NZ-FXE BATTERY / CHARGING  SERVICE DATA  


Charging circuit without load S34B20R 3 to 4 A
Positive (+) terminal - Negative (-) terminal 20°C (68°F), Power switch off 12.5 V or higher
Auxiliary battery is OK
11.0 to 12.5 V
Recharge auxiliary battery
Below 11.0 V
Replace auxiliary battery
Fuse Standard resistance Below 1 Ω
DC/ DC converter assembly Current flowing from auxiliary battery Auxiliary battery positive cable Power switch on (READY) (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.) 0 A or less
(no current from auxiliary battery)
Auxiliary battery voltage Positive (+) terminal - Negative (-) terminal 13 to 15 V
Auxiliary battery thermometer sensor Standard Resistance 1 - 2 3.00 to 3.73 kΩ at 10°C (50°F)
2.45 to 2.88 kΩ at 15°C (59°F)
1.95 to 2.30 kΩ at 20°C (68°F)
1.60 to 1.80 kΩ at 25°C (77°F)
1.28 to 1.47 kΩ at 30°C (86°F)
1.00 to 1.22 kΩ at 35°C (95°F)
0.80 to 1.00 kΩ at 40°C (104°F)
0.65 to 0.85 kΩ at 45°C (113°F)
0.50 to 0.70 kΩ at 50°C (122°F)
0.44 to 0.60 kΩ at 55°C (131°F)
0.36 to 0.50 kΩ at 60°C (140°F)