Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2011.12–2014.12
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277924 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A0D-350  High Voltage System Inter-Lock Circuit High  P0A0D-351  High Voltage System Inter-Lock Circuit High  


DESCRIPTION

When the power management control ECU detects that a safety device is operated, it will prohibit hybrid system operation or shut off the system main relay. There are three safety devices in three different locations. The first safety device is located at the service plug grip. The second one is located at the frame wire that is connected to the inverter with converter assembly. The third one is located at the inverter terminal cover where the motor cable is connected to the inverter with converter assembly. If the service plug grip, inverter terminal cover, or frame wire is removed, the interlock signal line will be open. If the vehicle is being driven, this condition will be determined to be an open circuit and the system main relays will not be shut off. If the safety devices are re-installed correctly, the system will return to normal when the power switch is turned on (IG).


DTC No. INF Code DTC Detection Condition Trouble Are
P0A0D 350 Operating any of the safety devices with the vehicle stopped (ILK signal is ON) and turning the power switch on (IG)
·

Wire harness or connector

·

Power management control ECU

·

Service plug grip

·

Inverter with converter assembly

·

Frame wire

·

Inverter terminal cover


P0A0D 351 Interlock signal line opens (ILK signal is ON) while the vehicle is being driven

WIRING DIAGRAM

A388949E01
0.333,1.177 0.49,1.375 0.156,0.198 10 false 2 0.479,1.177 0.813,1.375 0.333,0.198 10 false GND 1.25,1.177 1.583,1.375 0.333,0.198 10 false ILK 1.521,1.167 1.677,1.365 0.156,0.198 10 false 1 1.646,1.167 1.802,1.365 0.156,0.198 10 false 36 1.865,1.167 2.25,1.365 0.385,0.198 10 false ILKO 0.458,1.542 0.792,1.74 0.333,0.198 10 false M42 0.458,1.698 1.552,2.083 1.094,0.385 10 false Service Plug Grip (Interlock Switch) 2.854,1.396 3.698,1.688 0.844,0.292 10 false Frame Wire 3.844,1.396 4.406,2.031 0.563,0.635 10 false Inverter Terminal Cover 4.958,1.167 5.344,1.365 0.385,0.198 10 false ILKI 5.271,1.167 5.427,1.365 0.156,0.198 10 false 35 5.74,1.167 5.896,1.365 0.156,0.198 10 false 32 5.969,1.167 6.354,1.365 0.385,0.198 10 false ILK 6.292,0.438 6.677,0.635 0.385,0.198 10 false +B 2.323,2.896 2.656,3.094 0.333,0.198 10 false A47 2.313,3.063 5.115,3.458 2.802,0.396 10 false Inverter with Converter Assembly 5.844,2.625 6.177,2.823 0.333,0.198 10 false A38 5.823,2.792 7.083,3.167 1.26,0.375 10 false Power Management Control ECU

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the power switch on (IG) and wait for 5 seconds or more.



PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Check if DTCs are output.

Result:
Result Proceed to
P0A0D only is output. A
P0A1D is output B



e.

Turn the power switch off.



A

2.CLEAR DTC

B

2.CLEAR DTC
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Read and record the DTCs and freeze frame data.


e.

Clear DTCs and freeze frame data.


f.

Turn the power switch off.



NEXT

3.CHECK DTC OUTPUT (HYBRID CONTROL)
3.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Check if DTCs are output.

Result:
Result Proceed to
P0A0D-350 or P0A0D-351 is output again. A
Neither P0A0D-350 or P0A0D-351 is output again. B



e.

Turn the power switch off.



A

4.CHECK SERVICE PLUG GRIP

B

10.CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CIRCUIT)
4.CHECK SERVICE PLUG GRIP
CAUTION:

Be sure to wear insulated gloves.


a.
A314624E01
0.102,0 0.572,0.369 0.471,0.369 10 *1

Check if the service plug grip is installed correctly.

Text in Illustration
*1 Service Plug Grip

Standard:

The service plug grip is fully pushed in as shown in the illustration.


NOTICE:
·

Insert the service plug grip until a click sound is heard.

·

If "UNLOCK" is printed on the service plug grip, push in the service plug grip until "UNLOCK" is not visible at all.



HINT:
·

For the removal and installation procedures (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>SERVICE PLUG GRIP>COMPONENTS).

·

P0A0D-350 is also set if the power switch is turned on (IG) with the service plug grip removed. Confirm the conditions when the malfunction occurred.





OK

5.CHECK INVERTER TERMINAL COVER

NG

INSTALL PARTS CORRECTLY

5.CHECK INVERTER TERMINAL COVER
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A258644

Check if the inverter terminal cover of the inverter with converter assembly is installed correctly.

OK:

The inverter terminal cover is installed correctly.




OK

6.CHECK FRAME WIRE

NG

INSTALL PARTS CORRECTLY

6.CHECK FRAME WIRE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A258644

Remove the inverter terminal cover from the inverter with converter assembly.


c.
A258645

Remove the inverter cover from the inverter with converter assembly.


d.
U158937E03
0.76,1.25 1.104,1.469 0.344,0.219 10 false P1

Check if the frame wire P1 is connected correctly.

OK:

The frame wire connector is connected correctly.



e.

Install the inverter cover.


f.

Install the inverter terminal cover.



OK

7.CHECK POWER MANAGEMENT CONTROL ECU

NG

INSTALL PARTS CORRECTLY

7.CHECK POWER MANAGEMENT CONTROL ECU
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A47 from the inverter with converter assembly.


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Turn the power switch on (IG).


e.
U158870E02
1.833,1.25 2.5,1.781 false 0.083,0.031 0.281,0.198 0.198,0.167 10 false *a 2.552,1.729 2.854,1.906 0.302,0.177 10 false ILKI 2.906,0.99 3.167,1.167 0.26,0.177 10 false A47

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A47-35 (ILKI) - Body ground Power switch on (IG) 11 to 14 V


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)

NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



f.

Turn the power switch off.


g.

Disconnect the cable from the negative (-) auxiliary battery terminal.


h.

Connect the inverter with converter assembly connector.



OK

8.CHECK INVERTER WITH CONVERTER ASSEMBLY (INTERLOCK)

NG

16.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)
8.CHECK INVERTER WITH CONVERTER ASSEMBLY (INTERLOCK)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A47 from the inverter with converter assembly.


c.
U158864E02
1.385,1.25 0.854,1.844 false 1.469,1.25 2.031,1.844 false 0.073,0.042 0.271,0.219 0.198,0.177 10 false *a 0.667,1.865 1.031,2.031 0.365,0.167 10 false ILKO 1.906,1.854 2.271,2.021 0.365,0.167 10 false ILKI 0.188,1.021 0.448,1.198 0.26,0.177 10 false A47

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
A47-35 (ILKI) - A47-36 (ILKO) Power switch off 10 Ω or less


Text in Illustration
*a Component without harness connected
(Inverter with Converter Assembly)


NOTICE:

Do not remove the inverter cover.


d.

Connect the inverter with converter assembly connector.



OK

9.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - BODY GROUND)

NG

14.CHECK INVERTER TERMINAL COVER
9.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - BODY GROUND)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A47 from the inverter with converter assembly.


c.

Install the service plug grip.


d.
U158871E02
1.938,1.25 2.469,1.781 false 0.104,0.052 0.302,0.219 0.198,0.167 10 false *a 2.542,1.719 2.896,1.896 0.354,0.177 10 false ILKO 2.896,0.979 3.156,1.156 0.26,0.177 10 false A47

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
A47-36 (ILKO) - Body ground Power switch off Less than 1 Ω


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


e.

Remove the service plug grip.


f.

Connect the inverter with converter assembly connector.



OK

10.CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CIRCUIT)

NG

11.CHECK SERVICE PLUG GRIP
10.CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CIRCUIT)
a.

Check the connections of each connector.

OK:

Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.




OK

NG

REPAIR OR REPLACE CONNECTOR

11.CHECK SERVICE PLUG GRIP
a.

Remove the service plug grip.


b.
A314958E01
0.083,0 0.329,0.218 0.246,0.218 10 *1

Check the condition of the service plug grip interlock.

Text in Illustration
*1 Service Plug Grip

OK:

Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.



c.
A314624E01
0.102,0 0.572,0.369 0.471,0.369 10 *1

Install the service plug grip.

NOTICE:
·

Insert the service plug grip until a click sound is heard.

·

If "UNLOCK" is printed on the service plug grip, push in the service plug grip until "UNLOCK" is not visible at all.



Text in Illustration
*1 Service Plug Grip



OK

12.CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CONNECTOR)

NG

12.CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CONNECTOR)
a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A267575E02
2.156,1.177 2.344,1.354 0.188,0.177 10 true *1

Check that the interlock connector at the service plug grip installation socket is connected correctly.

Text in Illustration
*1 Interlock Connector

OK:

The connector is connected correctly.




OK

13.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - SERVICE PLUG GRIP)

NG

INSTALL PARTS CORRECTLY

13.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - SERVICE PLUG GRIP)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A47 from the inverter with converter assembly.


c.

Disconnect connector M42 from the service plug.


d.
A380677E01
0.167,0.917 0.583,1.167 0.417,0.25 2.375,1.719 1.823,1.271 false 0.094,0.104 0.406,0.302 0.313,0.198 10 false *a 0.25,0.958 0.708,1.156 0.458,0.198 10 false A47 2.427,1.656 2.885,1.854 0.458,0.198 10 false ILKO

A380678E01
2.333,2.833 2.75,3.083 0.417,0.25 1.167,2.74 1.917,3.021 false 0.896,2.646 1.354,2.844 0.458,0.198 10 false ILK 0.094,0.094 0.552,0.292 0.458,0.198 10 false *b 2.396,2.875 2.854,3.073 0.458,0.198 10 false M42

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
A47-36 (ILKO) - M42-1 (ILK) Power switch off Below 1 Ω


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Front view of wire harness connector
(to Service Plug Grip)


e.

Connect the service plug grip connector.


f.

Connect the inverter with converter assembly connector.



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (SERVICE PLUG GRIP - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - SERVICE PLUG GRIP)

14.CHECK INVERTER TERMINAL COVER
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A258644

Remove the inverter terminal cover from the inverter with converter assembly.


c.
A268140

Check the condition of the inverter terminal cover interlock.

OK:

Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.



d.

Install the inverter terminal cover.



OK

15.CHECK FRAME WIRE (FRAME WIRE CONNECTOR)

NG

15.CHECK FRAME WIRE (FRAME WIRE CONNECTOR)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A258644

Remove the inverter terminal cover from the inverter with converter assembly.


c.
A258645

Remove the inverter cover from the inverter with converter assembly.


d.
U158937E03
0.76,1.25 1.104,1.469 0.344,0.219 10 false P1

Disconnect the frame wire P1 from the inverter with converter assembly.


e.
A215624

Check the frame wire interlock.

OK:

Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.



f.

Connect the frame wire to the inverter with converter assembly.


g.

Install the inverter cover.


h.

Install the inverter terminal cover.



OK

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

NG

16.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A47 from the inverter with converter assembly.


c.
A388950E01
1.333,1.75 1.75,2 0.417,0.25 2.833,3.417 3.25,3.667 0.417,0.25 0.844,1.99 1.229,2.333 false 1.781,3.719 2.188,4.292 false 0.115,0.094 0.427,0.292 0.313,0.198 10 false *a 0.115,2.646 0.427,2.844 0.313,0.198 10 false *b 1.156,2.333 1.469,2.531 0.313,0.198 10 false ILK 1.406,1.792 1.719,1.99 0.313,0.198 10 false A38 2.125,4.302 2.438,4.5 0.313,0.198 10 false ILKI 2.906,3.458 3.219,3.656 0.313,0.198 10 false A47

Disconnect connector A38 from the power management control ECU.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
A38-32 (ILK) - A47-35 (ILKI) Power switch off Below 1 Ω


Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)
*b Front view of wire harness connector
(to Inverter with Converter Assembly)


e.

Connect the power management control ECU connector.


f.

Connect the inverter with converter assembly connector.



OK

NG