When the hybrid vehicle control ECU detects that a safety device is operated, it will prohibit hybrid system operation or shut off the system main relay. There are three safety devices in three different locations. The first safety device is located at the service plug grip. The second one is located at the frame wire that is connected to the inverter with converter assembly. The third one is located at the inverter terminal cover where the motor cable is connected to the inverter with converter assembly. If the service plug grip, inverter terminal cover, or frame wire is removed, the interlock signal line will be open. If the vehicle is being driven, this condition will be determined to be an open circuit and the system main relays will not be shut off. If the safety devices are re-installed correctly, the system will return to normal when the power switch is turned on (IG).
| DTC No. | INF Code | DTC Detection Condition | Trouble Are |
|---|---|---|---|
| P0A0D | 350 | Operating any of the safety devices with the vehicle stopped (ILK signal is ON) and turning the power switch on (IG) | ·
Wire harness or connector ·
Hybrid vehicle control ECU ·
Service plug grip ·
Inverter with converter assembly ·
Frame wire ·
Inverter terminal cover |
| P0A0D | 351 | Interlock signal line opens (ILK signal is ON) while the vehicle is being driven |
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (IG) and wait for 5 seconds or more.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A0D only is output. | A |
| P0A1D is output | B |
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the power switch off.
NEXT
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A0D-350 or P0A0D-351 is output again. | A |
| Neither P0A0D-350 or P0A0D-351 is output again. | B |
Turn the power switch off.
A
B
Be sure to wear insulated gloves.
Check if the service plug grip is installed correctly.
| *1 | Service Plug Grip |
The service plug grip is fully pushed in as shown in the illustration.
Insert the service plug grip until a click sound is heard.
If "UNLOCK" is printed on the service plug grip, push in the service plug grip until "UNLOCK" is not visible at all.
For the removal and installation procedures (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>SERVICE PLUG GRIP>COMPONENTS).
P0A0D-350 is also set if the power switch is turned on (IG) with the service plug grip removed. Confirm the conditions when the malfunction occurred.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check if the inverter terminal cover of the inverter with converter assembly is installed correctly.
The inverter terminal cover is installed correctly.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Remove the inverter cover from the inverter with converter assembly.
Check if the frame wire P1 is connected correctly.
The frame wire connector is connected correctly.
Install the inverter cover.
Install the inverter terminal cover.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A47 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A47-35 (ILKI) - Body ground | Power switch on (IG) | 11 to 14 V |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A47 from the inverter with converter assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A47-35 (ILKI) - A47-36 (ILKO) | Power switch off | 10 Ω or less |
| *a | Component without harness connected
(Inverter with Converter Assembly) |
Do not remove the inverter cover.
Connect the inverter with converter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A47 from the inverter with converter assembly.
Install the service plug grip.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A47-36 (ILKO) - Body ground | Power switch off | Less than 1 Ω |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Remove the service plug grip.
Connect the inverter with converter assembly connector.
OK
NG
Check the connections of each connector.
Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.
OK
NG
Remove the service plug grip.
Check the condition of the service plug grip interlock.
| *1 | Service Plug Grip |
Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
Install the service plug grip.
Insert the service plug grip until a click sound is heard.
If "UNLOCK" is printed on the service plug grip, push in the service plug grip until "UNLOCK" is not visible at all.
| *1 | Service Plug Grip |
OK
NG
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check that the interlock connector at the service plug grip installation socket is connected correctly.
| *1 | Interlock Connector |
The connector is connected correctly.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A47 from the inverter with converter assembly.
Disconnect connector M42 from the service plug.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A47-36 (ILKO) - M42-1 (ILK) | Power switch off | Below 1 Ω |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector
(to Service Plug Grip) |
Connect the service plug grip connector.
Connect the inverter with converter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Check the condition of the inverter terminal cover interlock.
Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.
Install the inverter terminal cover.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Remove the inverter cover from the inverter with converter assembly.
Disconnect the frame wire P1 from the inverter with converter assembly.
Check the frame wire interlock.
Dirt or foreign objects have not entered the connection, and there is no evidence of contamination.
Connect the frame wire to the inverter with converter assembly.
Install the inverter cover.
Install the inverter terminal cover.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A47 from the inverter with converter assembly.
Disconnect connector A72 from the hybrid vehicle control ECU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A72-13 (ILK) - A47-35 (ILKI) | Power switch off | Below 1 Ω |
| *a | Rear view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Connect the hybrid vehicle control ECU connector.
Connect the inverter with converter assembly connector.
OK
NG