Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2011.12–2014.12
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277924 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P2532-772  Ignition Switch Run Position Circuit High  


DESCRIPTION

The power source and HV CPU processors and their functions are integrated into the power management control ECU. The power source CPU and HV CPU use CAN communication to communicate with each other inside the power management control ECU. The power source CPU controls the opening and closing of the IG2 relay. The HV CPU detects that the IG2 relay is stuck ON (closed) based on relay operation information received from the power source CPU via CAN communication.

DTC No. INF Code DTC Detection Condition Trouble Area
P2532 772 Voltage is still applied to IG2 terminal although an IG2 relay off command is received from the power source CPU.
·

Power management control ECU

·

No. 1 integration relay (IG2 relay)

·

Wire harness or connector



HINT:

If DTC P2532-772 is stored, the vehicle will turn off.


WIRING DIAGRAM

A279477E02
5.51,1.594 6.313,1.771 0.802,0.177 10 false A39 5.51,1.76 6.906,2.135 1.396,0.375 10 false Power Management Control ECU 5.802,0.625 6.313,0.802 0.51,0.177 10 false IG2 4.156,0.615 4.375,0.792 0.219,0.177 10 false 2D 4.198,0.406 4.417,0.583 0.219,0.177 10 false 4 4.198,0.854 4.417,1.031 0.219,0.177 10 false 3 4.156,1.052 4.375,1.229 0.219,0.177 10 false 2D 1.875,0.604 2.094,0.781 0.219,0.177 10 false 2E 1.906,0.406 2.125,0.583 0.219,0.177 10 false 1 1.906,0.833 2.125,1.01 0.219,0.177 10 false 2 1.875,1.042 2.094,1.219 0.219,0.177 10 false 2D 5.802,1.063 6.313,1.24 0.51,0.177 10 false IG2D 5.615,0.51 5.771,0.688 0.156,0.177 10 false 1 5.615,0.958 5.771,1.135 0.156,0.177 10 false 2 3.302,1.458 3.594,1.635 0.292,0.177 10 false IG2 2.365,1.865 4.094,2.042 1.729,0.177 10 false No. 1 Integration Relay 4.708,0.76 5.427,0.938 0.719,0.177 10 false IG2 NO. 2 2.479,0.771 2.771,0.948 0.292,0.177 10 false IG2 0.906,1.458 1.5,1.823 0.594,0.365 10 false Auxiliary Battery 0.802,0.969 1.208,1.188 0.406,0.219 10 false MAIN 1.188,0.781 1.458,0.938 0.271,0.156 10 false P/I

CAUTION / NOTICE / HINT

HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the power switch on (IG) and wait for 15 seconds or more.

2.

Turn the power switch off and wait for 30 seconds or more.



PROCEDURE

1.CHECK HARNESS AND CONNECTOR (+B SHORT)
a.
U181221E02
1.667,2.25 2.01,2.094 false 1.594,2.25 2.01,2.479 false 1.344,2.885 1.615,3.052 0.271,0.167 10 false A39 2.052,2 2.375,2.167 0.323,0.167 10 false IG2 2.042,2.417 2.427,2.594 0.385,0.177 10 false IG2D 0.052,0.063 0.208,0.229 0.156,0.167 10 false *a

Disconnect connector A39 from the power management control ECU.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A39-1 (IG2) - Body ground Power switch off Below 1 V
A39-2 (IG2D) - Body ground Power switch off Below 1 V


Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)

Result:
Result Proceed to
NG A
OK B



c.

Connect the power management control ECU connector.



A

2.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - IG2 RELAY)

B

2.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - IG2 RELAY)
a.

Disconnect connector A39 from the power management control ECU.


b.

Remove the No. 1 integration relay from the No. 2 engine room relay block and No. 2 junction block assembly.


c.
U181221E02
1.667,2.25 2.01,2.094 false 1.594,2.25 2.01,2.479 false 1.344,2.885 1.615,3.052 0.271,0.167 10 false A39 2.052,2 2.375,2.167 0.323,0.167 10 false IG2 2.042,2.417 2.427,2.594 0.385,0.177 10 false IG2D 0.052,0.063 0.208,0.229 0.156,0.167 10 false *a

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A39-1 (IG2) - Body ground Power switch off Below 1 V
A39-2 (IG2D) - Body ground Power switch off Below 1 V


Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)


d.

Install the No. 1 integration relay.


e.

Connect the power management control ECU connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR