Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2011.12–2014.12
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277924 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0343-747  Camshaft Position Sensor "A" Circuit High Input  


DESCRIPTION

The MG ECU stores this DTC when the engine speed pulse input from the ECM is abnormal.

DTC No. INF Code DTC Detection Condition Trouble Area
P0343 747 GI signal is not input for 2 sec. or more while the engine is running.
·

SFI system

·

Inverter with converter assembly

·

ECM

·

Wire harness or connector



WIRING DIAGRAM

A321433E02
4.917,2.844 5.344,3.021 0.427,0.177 10 false A47 4.917,3 7.083,3.177 2.167,0.177 10 false Inverter with Converter Assembly 5.688,1.083 5.906,1.25 0.219,0.167 10 false GI 5.469,1.354 5.688,1.521 0.219,0.167 10 false 30 5.688,2.177 6.115,2.344 0.427,0.167 10 false GND1 5.448,2.052 5.667,2.219 0.219,0.167 10 false 28 2.979,2.833 3.375,3.01 0.396,0.177 10 false ECM 2.281,2.156 2.479,2.333 0.198,0.177 10 false E1 1.99,1.99 2.208,2.167 0.219,0.177 10 false 16 0.094,1.667 1.802,1.979 1.708,0.313 10 false Camshaft Position Sensor 2.771,1.313 3.01,1.552 0.24,0.24 10 false IC 4.188,1.031 4.385,1.208 0.198,0.177 10 false 43 3.771,1.115 4.104,1.292 0.333,0.177 10 false G2O 5.719,1.458 6.146,1.625 0.427,0.167 10 false DRN5 5.458,1.083 5.677,1.25 0.219,0.167 10 false 29 4.146,1.208 4.438,1.365 0.292,0.156 10 false A40 1.99,2.177 2.281,2.333 0.292,0.156 10 false C9 1.604,2.188 1.896,2.344 0.292,0.156 10 false C10 1.656,1.99 1.875,2.167 0.219,0.177 10 false 16 2,2.365 2.219,2.542 0.219,0.177 10 false *2 1.656,2.365 1.875,2.542 0.219,0.177 10 false *1 0.198,3.333 0.885,3.531 0.688,0.198 10 false *1: LHD 1.01,3.333 1.698,3.531 0.688,0.198 10 false *2: RHD

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the power switch on (READY).

2.

With the vehicle stopped, move the shift lever to P.

3.

Depress the accelerator pedal to start the engine.

4.

Depress the accelerator pedal and maintain the engine speed at 1000 rpm or more for 5 seconds or more.



PROCEDURE

1.CHECK DTC OUTPUT (ENGINE AND ECT)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Engine and ECT/ DTC.


d.

Check if DTCs are output.

Result:
Result Proceed to
SFI system DTCs are not output. A
Any of the following DTCs are also output. B


DTC No. Relevant Diagnosis
P0340 Camshaft Position Sensor Circuit Malfunction


e.

Turn the power switch off.



A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Check if DTCs are output.

Result:
Result Proceed to
None of the following DTCs are output. A
Any of the following DTCs are also output. B


DTC No. Relevant Diagnosis
P0A1B (all INF codes)*1 Drive Motor "A" Control Module

HINT:
·

*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

·

P0343-747 may be set due to a malfunction which also causes the DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.




e.

Turn the power switch off.



A

3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A267460

Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (See page General>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE).

NOTICE:

Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.


OK:

The connectors are connected securely and there are no contact pressure problems.


HINT:

When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.




OK

4.CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)

NG

CONNECT SECURELY

4.CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)
a.

Check the connector connections and contact pressure of the relevant terminals for the ECM connectors (See page General>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE).

A279819E01
0.314,0.023 0.591,0.243 0.276,0.221 10 *A 3.457,0.023 3.734,0.243 0.276,0.221 10 *B

Text in Illustration
*A for LHD *B for RHD

NOTICE:

Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.


OK:

The connectors are connected securely and there are no contact pressure problems.


HINT:

When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.




OK

5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM)

NG

CONNECT SECURELY

5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the connector A47 from the inverter with converter assembly.


c.

Disconnect connector A40 from the ECM.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the power switch on (IG).


f.
A380674E01
1.5,4.25 1.917,4.5 0.417,0.25 1.5,1.667 1.917,1.917 0.417,0.25 0.917,1.667 1.083,1.115 true 2.51,4.333 2.177,3.688 true 0.146,0.115 0.458,0.313 0.313,0.198 10 false *a 0.094,2.604 0.406,2.802 0.313,0.198 10 false *b 0.802,1.719 1.115,1.917 0.313,0.198 10 false GI 1.573,1.708 1.885,1.906 0.313,0.198 10 false A47 1.573,4.292 1.885,4.49 0.313,0.198 10 false A40 2.438,4.354 2.75,4.552 0.313,0.198 10 false G2O

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A47-29 (GI) - Body ground Power switch on (IG) Below 1 V


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Front view of wire harness connector
(to ECM)

NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly connector and ECM connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



g.

Turn the power switch off.


h.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Switch Condition Specified Condition
A47-29 (GI) - A40-43 (G2O) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Switch Condition Specified Condition
A47-29 (GI) or A40-43 (G2O) - Body ground and other terminals Power switch off 10 kΩ or higher



i.

Disconnect the cable from the negative (-) auxiliary battery terminal.


j.

Connect the ECM connector.


k.

Connect the inverter with converter assembly connector.



OK

6.CHECK INVERTER WITH CONVERTER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect connector A47 from the inverter with converter assembly.


c.
U158863E03
1.938,1.25 2.385,1.896 false 1.094,1.208 0.813,1.854 false 2.323,1.917 2.521,2.073 0.198,0.156 10 false GI 0.104,0.031 0.26,0.188 0.156,0.156 10 false *a 0.625,1.885 1.052,2.042 0.427,0.156 10 false GND1 1.458,1.896 1.729,2.063 0.271,0.167 10 false A47

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
A47-29 (GI) - A47-28 (GND1) Power switch off 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(Inverter with Converter Assembly)


d.

Connect the inverter with converter assembly connector.



OK

NG

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS