The water pump with motor assembly transmits rotation speed information to the hybrid vehicle control ECU (HV CPU). The hybrid vehicle control ECU (HV CPU) monitors the speed and detects malfunctions.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0C73 | 776 | A speed or intermittent stop malfunction occurs in the inverter water pump assembly.
A revolution malfunction (speed is too high/low or stop) or an intermittent stop malfunction (operation stops intermittently when the revolution speed is abnormal) occurs in the inverter water pump assembly. |
·
Inverter cooling system ·
Wire harness or connector ·
Inverter water pump assembly ·
Hybrid vehicle control ECU |
The inverter water pump assembly operates when the power switch is on (READY).
| DTC No. | INF Code | Data List Item |
|---|---|---|
| P0C73 | 776 | ·
W/P Run Control Duty*1 ·
Inverter W/P Revolution ·
Ready signal |
*1: The inverter water pump assembly operates when the power switch is on (READY).
| DTC No. | INF Code | Active Test |
|---|---|---|
| P0C73 | 776 | Activate the Water Pump*1 |
*1: This is an Active Test of the inverter water pump assembly.
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 2 minutes or more.
If this vehicle is jump started, etc. and excessive voltage is applied to the auxiliary battery, the inverter water pump assembly may suspend control as a self-protection function and store DTC.
(When the auxiliary battery voltage returns to normal, the inverter water pump assembly will resume normal operation. In this case it is not necessary to replace the inverter water pump assembly.)
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
When the inverter water pump assembly operation command line (SWP - IWP) is open or its connection is faulty, the inverter water pump assembly is operated forcibly.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Inverter W/P Revolution.
Read the Data List.
| Tester Display | Switch Condition | Specified Condition |
|---|---|---|
| Inverter W/P Revolution | Power switch on (IG) | 625 rpm or less |
When the inverter water pump assembly is not operating, the Data List item "Inverter W/P Revolution" displays a value lower than 625 rpm.
Turn the power switch off.
OK
NG
NEXT
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Select Inverter W/P Revolution in the Data List.
While performing the "Activate the Water Pump" Active Test, check Inverter W/P Revolution in the Data List.
| Tester Display | Switch Condition | Specified Condition |
|---|---|---|
| Inverter W/P Revolution | Power switch on (IG) | 2250 to 5625 rpm |
Perform the Active Test with the inverter coolant temperature between -15 and 65°C (5 to 149°F).
When the inverter water pump assembly is not operating, the Data List item "Inverter W/P Revolution" displays a value lower than 625 rpm.
Turn the power switch off.
OK
NG
A
B
OK
NG
Check the connector connections and contact pressure of the relevant terminals for the inverter water pump assembly connector (See page General>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE).
The connectors are connected securely and there are no contact pressure problems.
OK
NG
Disconnect connector A71 from the hybrid vehicle control ECU.
Disconnect connector A53 from the inverter water pump assembly.
Measure the resistance according to the value(s) in the table below.
| *a | Rear view of wire harness connector
(to Hybrid Vehicle Control ECU) |
*b | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A53-3 (SWP) - A71-13 (IWP) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A53-3 (SWP) or A71-13 (IWP) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Check the condition (looseness, deterioration, etc.) of the wire to body ground for the inverter water pump assembly.
Connect the hybrid vehicle control ECU connector.
Connect the inverter water pump assembly connector.
OK
NG
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the intelligent tester to the DLC3.
Remove the IGCT No. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / ECU Data List / Inverter W/P Revolution.
Read the Data List.
| Tester Display | Switch Condition | Specified Condition |
|---|---|---|
| Inverter W/P Revolution | Power switch on (IG) | 125 rpm or less |
Turn the power switch off.
Install the IGCT No. 3 fuse.
OK
NG
Disconnect connector A71 from the hybrid vehicle control ECU.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A71-13 (IWP) - G80-6 (E1) | Power switch on (IG) | 11 to 14 V |
| *a | Rear view of wire harness connector
(to Hybrid Vehicle Control ECU) |
Turning the power switch on (IG) with the hybrid vehicle control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Connect the hybrid vehicle control ECU connector.
OK
NG
Turn the power switch on (IG).
While turning the power switch on (IG), check the waveform between the hybrid vehicle control ECU terminals.
| Item | Content |
|---|---|
| Terminal | A71-13 (IWP) - G80-6 (E1) |
| Equipment Setting | 5 V/DIV., 50 ms./DIV. |
| Condition | Power switch on (IG) |
| *a | Component with Harness Connected
(Hybrid Vehicle Control ECU) |
Waveform duty ratio is between 3% and 9%.
Turn the power switch off.
OK
NG
NEXT
After replacing the inverter water pump assembly, add HV coolant and perform air bleeding.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>COOLANT(for Inverter)>REPLACEMENT