Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2014.12
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277924 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0E05-328  Generator Phase V Current Sensor Circuit Range / Performance  P0E09-336  Generator Phase W Current Sensor Circuit Range / Performance  P1C3E-333  Generator Phase V Current Sensor Correlation  P1C3F-341  Generator Phase W Current Sensor Correlation  P1C54-326  Generator Phase V Current Sensor Sub Circuit Range / Performance  P1C59-334  Generator Phase W Current Sensor Sub Circuit Range / Performance  P1C71-515  Generator Phase V Current Sensor Offset Range / Performance  P1C72-516  Generator Phase W Current Sensor Offset Range / Performance  


DESCRIPTION

The MG ECU located in the inverter with converter assembly monitors the generator inverter current sensors. P0A72 and P0A75 indicate malfunctions in the current sensors, and they do not indicate malfunctions in the high-voltage system.

DTC No. INF Code DTC Detection Condition Trouble Area
P0E05 328 Malfunction in generator inverter current sensor (phase V main sensor)*
(1 trip detection logic)
Inverter with converter assembly
P0E09 336 Malfunction in generator inverter current sensor (phase W main sensor)*
(1 trip detection logic)
P1C3E 333 Malfunction in generator inverter current sensor (performance problem or open of phase V sensors)*
Detects an abnormal condition when the difference between the output of the phase V main sensor and phase V sub sensor is larger than the standard.
(1 trip detection logic)
P1C3F 341 Malfunction in generator inverter current sensor (performance problem or open of phase W sensors)*
Detects an abnormal condition when the difference between the output of the phase W main sensor and phase W sub sensor is larger than the standard.
(1 trip detection logic)
P1C54 326 Malfunction in generator inverter current sensor (phase V sub sensor)*
(1 trip detection logic)
P1C59 334 Malfunction in generator inverter current sensor (phase W sub sensor)*
(1 trip detection logic)
P1C71 515 Malfunction in generator inverter current sensor (phase V main and sub sensors offset)*
(1 trip detection logic)
P1C72 516 Malfunction in generator inverter current sensor (phase W main and sub sensors offset)*
(1 trip detection logic)

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the power switch on (IG) and wait for 5 seconds or more.

2.

Turn the power switch on (READY) with the shift lever in P and wait for 5 seconds or more.

3.

Move the shift lever to N and wait for 5 seconds or more.

4.

Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.

5.

Drive the vehicle forward with the shift lever in D for 5 m or more.

6.

Drive the vehicle backward with the shift lever in R for 5 m or more.



PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Check if DTCs are output.

Result:
Result Proceed to
Only P0A72 or P0A75 is output, or DTCs other than the ones in the table below are also output. A
P0A7A-203 is output. B



e.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

OK

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

NG

CONNECT SECURELY