| *1 | Battery Smart Unit | - | - |
| Terminal No.
(Symbols) |
Wiring Color | Terminal Description | Condition | Standard (V) |
|---|---|---|---|---|
| d1-2 (TB2) - d1-8 (GB2) | L - L | Battery temperature sensor 2 | HV battery temperature: -40 to 90 °C (-40 to 194 °F) | 4.8 (-40 °C (-40 °C)) to 1.0 (90 °C (194 °F)) |
| d1-3 (TB1) - d1-9 (GB1) | W - W | Battery temperature sensor 1 | HV battery temperature: -40 to 90 °C (-40 to 194 °F) | 4.8 (-40 °C (-40 °C)) to 1.0 (90 °C (194 °F)) |
| d1-4 (TBO) - d1-10 (GBO) | R - R | Battery temperature sensor 0 | HV battery temperature: -40 to 90 °C (-40 to 194 °F) | 4.8 (-40 °C (-40 °C)) to 1.0 (90 °C (194 °F)) |
| d1-5 (IB) - d1-12 (GIB) | Y - B | Current sensor | Power switch on (READY) | 0.5 to 4.5 |
| d1-6 (VIB) - d1-12 (GIB) | BR - B | Power source for battery current sensor | Power switch on (IG) | 4.5 to 5.5 |
| M39-3 (IGCT) - M39-6 (GND) | L - W-B | Control signal | Power switch on (READY) | 11 to 14 |
| M39-1 (BTH+) - M39-6 (GND) | R - W-B | Serial communication | Power switch on (IG) | Pulse generation
(waveform 1) |
| M39-4 (BTH-) - M39-6 (GND) | G - W-B | Serial communication | Power switch on (IG) | Pulse generation
(waveform 2) |
| M39-5 (FP0) - M39-6 (GND) | B - W-B | Battery cooling blower No. 0 monitor signal | Cooling blower activated | Pulse generation
(waveform 3) |
| Cooling blower stopped | 4.5 to 5.5 V | |||
| M39-6 (GND) - Body ground | W-B | Ground | Always (continuity check) | Below 1 Ω |
Oscilloscope waveforms
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1
| Item | Content |
|---|---|
| Terminal | M39-1 (BTH+) - M39-6 (GND) |
| Equipment Setting | 2 V/DIV., 500 μs/DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 2
| Item | Content |
|---|---|
| Terminal | M39-4 (BTH-) - M39-6 (GND) |
| Equipment Setting | 2 V/DIV., 500 μs/DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 3
| Item | Content |
|---|---|
| Terminal | M39-5 (FP0) - M39-6 (GND) |
| Equipment Setting | 5 V/DIV., 1 ms/DIV. |
| Condition | Battery cooling blower assembly operating (Active Test of cooling fan being performed) |
The frequency of the waveform will vary with the operating speed of the battery cooling blower assembly.