Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › INVERTER WITH CONVERTER › 2011.12–2014.12
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277927 INVERTER WITH CONVERTER A

HYBRID / BATTERY CONTROL  INVERTER WITH CONVERTER  REMOVAL  


PROCEDURE

Hide G9223 4.REMOVE INVERTER TERMINAL COVER

a.
A266706E07
2.521,0.906 2.521,1.25 true 2.438,1.271 2.708,1.448 0.271,0.177 10 false *1

Remove the 2 bolts and inverter terminal cover.

Text in Illustration
*1 Interlock Connector

CAUTION:

An interlock connector is installed to the inverter terminal cover. Make sure to remove the inverter terminal cover before removing the inverter cover.


NOTICE:

Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.



Hide G9221 5.REMOVE INVERTER COVER

CAUTION:

Wear insulated gloves.


a.
A266688

Remove the 7 bolts and inverter cover.

CAUTION:

An interlock connector is installed to the inverter terminal cover. Make sure to remove the inverter terminal cover before removing the inverter cover.



Hide 6.CHECK TERMINAL VOLTAGE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A267098

Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.

Standard voltage:

0 V


HINT:

Use measuring range of DC 750 V or more on the voltmeter.



Hide 82111 7.DISCONNECT ENGINE ROOM MAIN WIRE

CAUTION:

Wear insulated gloves.


NOTICE:
·

Insulate the disconnected terminals with insulating tape.

·

Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.



a.
A266684

Raise the lock lever and disconnect the inverter with converter connector.


b.
A214646

Disconnect the engine wire from the engine room main wire.


c.
A266686

Disconnect the hose clamp.

NOTICE:

Do not remove the hose clamp from the hose.



d.

Remove the 2 bolts.


e.

Disconnect the clamp and engine room main wire.


Hide 82164 8.DISCONNECT FRAME WIRE

CAUTION:

Wear insulated gloves.


NOTICE:
·

Insulate the disconnected terminals with insulating tape.

·

Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.



a.
A266691

Disconnect the harness clamp.


b.
A266689

Remove the 4 bolts, and disconnect the frame wire (high voltage cables of the hybrid battery) from the inverter with converter assembly.


Hide G1148 9.DISCONNECT MOTOR CABLE

CAUTION:

Wear insulated gloves.


NOTICE:
·

Insulate the disconnected terminals with insulating tape.

·

Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.



a.

Disconnect the motor cable (for MG 1)

i.
A266692

Remove the 5 bolts, and disconnect the high voltage cables of the motor cable for (MG1) from the inverter with converter assembly.



b.

Disconnect the motor cable (for MG 2)

i.
A266693

Remove the 5 bolts, and disconnect the high voltage cables of the motor cable (for MG2) from the inverter with converter assembly.



Hide 82122 10.DISCONNECT NO. 2 ENGINE WIRE

CAUTION:

Wear insulated gloves.


NOTICE:
·

Insulate the disconnected terminals with insulating tape.

·

Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.



a.
A266694E05
2.542,0.927 2.75,1.104 0.208,0.177 10 true A 0.906,0.781 1.042,1.021 0.135,0.24 10 false B 1.208,1.271 1.344,1.438 0.135,0.167 10 true B 0.969,1.854 1.104,2.021 0.135,0.167 10 true B 0.125,1.5 0.26,1.667 0.135,0.167 10 true B

Remove the bolt (A).


b.

Remove the 4 bolts (B), and disconnect the No. 2 engine wire (high voltage cables for the air conditioning compressor) from the inverter with converter assembly.


Hide G9221 11.INSTALL INVERTER COVER

CAUTION:

Wear insulated gloves.


a.
A266688

Temporarily install the inverter cover with the 7 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.

NOTICE:

Visually confirm that the inverter cover waterproofing rubber is securely installed before installing the upper inverter cover.



Hide G9223 12.INSTALL INVERTER TERMINAL COVER

CAUTION:

Wear insulated gloves.


a.
A266706E07
2.521,0.906 2.521,1.25 true 2.438,1.271 2.708,1.448 0.271,0.177 10 false *1

Temporarily install the inverter terminal cover with the 2 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.

Text in Illustration
*1 Interlock Connector

NOTICE:
·

Visually confirm that the inverter cover waterproofing rubber is securely installed before installing the inverter terminal cover.

·

Make sure that the interlock is fully engaged.




Hide 82164 13.DISCONNECT FRAME WIRE

a.
A266697

Remove the relay block cover.


b.
A266698

Disconnect the connector.


c.
A266699

Disengage the 2 claws and remove the No. 1 relay block cover.


d.
A267091

Remove the nut and disconnect the No. 2 engine room wire.


e.

Release the 2 claws, and disconnect the No. 2 engine room wire.


Hide G90A0A 14.DISCONNECT NO. 1 INVERTER COOLING HOSE ASSEMBLY

a.
A266702E01
2.534,0.417 2.849,0.705 0.316,0.288 10 *1 1.991,1.03 2.414,0.478 2.414,0.478 2.485,0.478 false

Release the retainer and disconnect the No. 1 inverter cooling hose assembly from the inverter with converter assembly.

Text in Illustration
*1 Retainer


b.
A266708

Put pieces of cloth into the pipes and in the disconnected hose, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.


Hide G90B0 15.DISCONNECT NO. 2 INVERTER COOLING HOSE ASSEMBLY

a.
A266700E02
1.667,1.271 1.313,0.969 1.313,0.969 1.25,0.969 false 1.083,0.896 1.271,1.063 0.188,0.167 10 true *1

Release the retainer and disconnect the No. 2 inverter cooling hose assembly from the inverter with converter assembly.

Text in Illustration
*1 Retainer


b.
A266708

Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hose with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.


Hide G9200 16.REMOVE INVERTER WITH CONVERTER ASSEMBLY

CAUTION:

Wear insulated gloves.


a.
A266707E02
1.979,0.729 2.365,0.354 2.365,0.354 2.427,0.354 true 2.438,0.281 2.656,0.458 0.219,0.177 10 true *1

Temporarily secure the No. 3 engine room wire with the inverter with converter assembly protector as shown in the illustration.

Text in Illustration
*1 Protector

HINT:

To prevent the No. 2 engine room wire from getting caught by other components, connect it to the protector before removing the inverter with converter assembly.



b.
A266704

Remove the 3 bolts and inverter with converter assembly.

NOTICE:
·

Since the inverter with converter assembly is very heavy, 2 people are needed to remove the inverter with converter assembly. When removing the inverter with converter assembly, do not damage the parts around it.

·

To prevent damage, do not hold the inverter with converter assembly by the connectors.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.




c.
A148374

Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the inverter so that coolant does not spill out.


Hide 17.REMOVE HIGH VOLTAGE FUSE

CAUTION:

Wear insulated gloves.


HINT:

Perform this procedure only when replacement of the high voltage fuse is necessary.


a.
A266706E07
2.521,0.906 2.521,1.25 true 2.438,1.271 2.708,1.448 0.271,0.177 10 false *1

Remove the 2 bolts and inverter terminal cover.

Text in Illustration
*1 Interlock Connector

NOTICE:

Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.



b.
A266688

Remove the 7 bolts and inverter cover.


c.
A266696

Remove the 2 bolts and high voltage fuse from the inverter with converter assembly.

NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.



d.
A266688

Temporarily install the inverter cover with the 7 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.

NOTICE:

Visually confirm that the inverter cover waterproofing rubber is securely installed before installing the inverter cover.



e.
A266706E07
2.521,0.906 2.521,1.25 true 2.438,1.271 2.708,1.448 0.271,0.177 10 false *1

Temporarily install the inverter terminal cover with the 2 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.

Text in Illustration
*1 Interlock Connector

NOTICE:
·

Visually confirm that the inverter terminal cover waterproofing rubber is securely installed before installing the inverter terminal cover.

·

Make sure that the interlock is fully engaged.