G92Z0
1.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
Inspect SMRB.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-1 (+) - P5-1 (CBI) | Auxiliary battery voltage is not applied between terminals M40- 1 (SMRB) and M40-2 (GND) | 10 kΩ or higher |
| A-1 (+) - P5-1 (CBI) | Auxiliary battery voltage is applied between terminals M40- 1 (SMRB) and M40-2 (GND) | Below 1 Ω |
| *a | Component without harness connected
(Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M40-1 (SMRB) - M40-2 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
If the result is not as specified, replace the hybrid battery junction block assembly or electric vehicle fuse.
Inspect SMRG.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| c1-1 (-) - P4-1 (CEI) | Auxiliary battery voltage is not applied between terminals M40- 3 (SMRG) and M40-2 (GND) | 10 kΩ or higher |
| c1-1 (-) - P4-1 (CEI) | Auxiliary battery voltage is applied between terminals M40- 3 (SMRG) and M40-2 (GND) | Below 1 Ω |
| *a | Component without harness connected
(Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M40-3 (SMRG) - M40-2 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
If the result is not as specified, replace the hybrid battery junction block assembly.
Inspect SMRP.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| P4-1 (CEI) - c1-1 (-) | Auxiliary battery voltage is not applied between terminals M40-4 (SMRP) and M40-2 (GND) | 10 kΩ or higher |
| P4-1 (CEI) - c1-1 (-) | Auxiliary battery voltage is applied between terminals M40-4 (SMRP) and M40-2 (GND) | 28.5 to 31.5 Ω |
| *a | Component without harness connected
(Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M40-4 (SMRP) - M40-2 (GND) | -40 to 80°C (-40 to 176°F) | 112 to 274 Ω |
If the result is not as specified, replace the hybrid battery junction block assembly.