25860D
1.INSPECT PURGE VSV
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 23 to 26 Ω |
If the result is not as specified, replace the purge VSV.
Apply auxiliary battery voltage between the terminals of the purge VSV and check that the following occurs when blowing air into port E.
| Measurement Condition | Specified Condition |
|---|---|
| Auxiliary battery voltage applied between terminals 1 and 2 | Air flows from port F |
| Auxiliary battery voltage not applied between terminals 1 and 2 | Air does not flow |
| *a | Air |
If the result is not as specified, replace the purge VSV.