16363
1.INSPECT COOLING FAN MOTOR
Check that the motor operates smoothly when the auxiliary battery is connected to the cooling fan motor connector.
| *a | Component without harness connected
(Cooling Fan Motor) |
Clamp the 400 A probe of an ammeter over the (+) wire of the cooling fan motor.
Measure the current while the motor is operating.
| Item | Condition | Specified Condition |
|---|---|---|
| Cooling fan motor | 20°C (68°F) at 12 V | 12.2 to 15.7 A |
If the result is not as specified, replace the cooling fan motor.