1.INSPECT POWER SWITCH
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 5 (SS1) - 6 (AGND) | Pushed | Below 1 Ω |
| 1 (SS2) - 6 (AGND) | Pushed | Below 1 Ω |
| 5 (SS1) - 6 (AGND) | Not pushed | 10 kΩ or higher |
| 1 (SS2) - 6 (AGND) | Not pushed | 10 kΩ or higher |
If the result is not as specified, replace the power switch.
Apply battery voltage between the terminals of the switch, and check the illumination condition of the power switch.
| *a | Power Switch Illumination | - | - |
| Measurement Condition | Specified Condition |
|---|---|
| Auxiliary battery positive (+) →Terminal 9 (SWIL)
Auxiliary battery negative (-) →Terminal 6 (AGND) |
Illuminates
(Power Switch Illumination) |
If the result is not as specified, replace the power switch.