89451A
1.INSPECT SHIFT LEVER POSITION SENSOR
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Shift Lever Position | Specified Condition |
|---|---|---|
| 7 (+B) - 1 (DB1) | D or B | Below 1 Ω |
| Except D or B | 10 kΩ or higher | |
| 7 (+B) - 2 (N) | N | Below 1 Ω |
| Except N | 10 kΩ or higher | |
| 7 (+B) - 3 (PR) | P or R | Below 1 Ω |
| Except P or R | 10 kΩ or higher | |
| 7 (+B) - 4 (PNB) | P, N or B | Below 1 Ω |
| Except P, N or B | 10 kΩ or higher | |
| 7 (+B) - 6 (DB2) | D or B | Below 1 Ω |
| Except D or B | 10 kΩ or higher | |
| 7 (+B) - 8 (P) | P | Below 1 Ω |
| Except P | 10 kΩ or higher | |
| 7 (+B) - 9 (R) | R | Below 1 Ω |
| Except R | 10 kΩ or higher |
| *a | Component without harness connected
(Shift Lever Position Sensor) |
If the result is not as specified, replace the shift lever position sensor.