Home › Power Source / Network › 1NZ-FXE BATTERY / CHARGING › BATTERY THERMOMETER SENSOR
RM2170E _57 Power Source / Network _057031 1NZ-FXE BATTERY / CHARGING _0278064 BATTERY THERMOMETER SENSOR G

1NZ-FXE BATTERY / CHARGING  BATTERY THERMOMETER SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 28865 1.INSPECT BATTERY THERMOMETER SENSOR

a.

Disconnect the connector from the battery thermometer sensor.

E319152E02
2.979,1.292 2.635,0.406 2.635,0.406 2.438,0.406 false 4.948,1.385 5.24,0.938 5.24,0.938 5.438,0.938 false 6.531,2.531 6.958,2.771 0.427,0.24 10 false (140) 3.76,0.208 4.896,0.542 1.135,0.333 10 false Resistance (kΩ) 6.594,2.375 7.031,2.781 0.438,0.406 10 false 60 6.073,2.531 6.5,2.771 0.427,0.24 10 false (122) 4.302,2.375 4.74,2.781 0.438,0.406 10 false 10 4.74,2.375 5.177,2.781 0.438,0.406 10 false 20 5.208,2.375 5.646,2.781 0.438,0.406 10 false 30 5.688,2.375 6.125,2.781 0.438,0.406 10 false 40 6.146,2.375 6.583,2.781 0.438,0.406 10 false 50 5.625,2.531 6.052,2.771 0.427,0.24 10 false (104) 5.188,2.531 5.615,2.771 0.427,0.24 10 false (86) 4.719,2.531 5.146,2.771 0.427,0.24 10 false (68) 4.281,2.531 4.708,2.771 0.427,0.24 10 false (50) 5.469,0.865 6.635,1.24 1.167,0.375 10 false Allowable Range 2.719,2.385 4.146,2.729 1.427,0.344 10 false Temperature (°C (°F)) 4.104,0.469 7.156,0.688 3.052,0.219 10 false 4.0 4.104,0.688 7.156,0.906 3.052,0.219 10 false 3.5 4.104,0.906 7.156,1.125 3.052,0.219 10 false 3.0 4.104,1.135 7.156,1.354 3.052,0.219 10 false 2.5 4.104,1.365 7.156,1.583 3.052,0.219 10 false 2.0 4.104,1.594 7.156,1.813 3.052,0.219 10 false 1.5 4.104,1.813 7.156,2.031 3.052,0.219 10 false 1.0 4.104,2.052 7.156,2.271 3.052,0.219 10 false 0.5 4.104,2.271 7.156,2.49 3.052,0.219 10 false 0.0 2.25,0.313 2.531,0.542 0.281,0.229 10 false *2 0.135,0.115 0.417,0.344 0.281,0.229 10 false *1


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
1 - 2 15°C (59°F) 2.45 to 2.88 kΩ
1 - 2 20°C (68°F) 1.95 to 2.30 kΩ
1 - 2 25°C (77°F) 1.60 to 1.80 kΩ
1 - 2 30°C (86°F) 1.28 to 1.47 kΩ
1 - 2 35°C (95°F) 1.00 to 1.22 kΩ
1 - 2 40°C (104°F) 0.80 to 1.00 kΩ
1 - 2 45°C (113°F) 0.65 to 0.85 kΩ
1 - 2 50°C (122°F) 0.50 to 0.70 kΩ
1 - 2 55°C (131°F) 0.44 to 0.60 kΩ
1 - 2 60°C (140°F) 0.36 to 0.50 kΩ


Text in Illustration
*1 Component without harness connected
(Battery Thermometer Sensor)
*2 Sensing Portion

NOTICE:
·

Hold the sensor only by its connector. Touching the sensor may change the resistance value.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).