The certification ECU (smart key ECU assembly) blinks the security indicator light when the immobiliser is set (power switch off, or driver door is opened and closed with power switch on (IG)).
Before replacing the certification ECU (smart key ECU assembly), refer to Service Bulletin.
When an engine immobiliser system DTC is output, first perform troubleshooting for the DTC.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Entry&Start / Active Test.
Perform the Active Test according to the display on the intelligent tester.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Immobiliser Indicator | Security indicator light | OFF/ON | - |
The security indicator light operates normally.
OK
NG
Disconnect the G1 combination meter assembly connector.
Disconnect the G79 certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G79-18 (IND)- G1-13 (LP) | Always | Below 1 Ω |
| G79-18 (IND) - Body ground | Always | 10 kΩ or higher |
OK
NG
Reconnect the G79 certification ECU (smart key ECU assembly) connector.
Measure the voltage and check the pulse according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G1-13 (LP) - Body ground | Power switch off → power switch on (IG) | Pulse generation → Below 2 V |
OK
NG