Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM › 2011.12–2017.06
RM2170E _59 Vehicle Exterior _057045 WINDOW / GLASS _0278147 POWER WINDOW CONTROL SYSTEM U

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM  FAIL-SAFE CHART  


POWER WINDOW OPERATION IN FAIL-SAFE MODE


HINT:

If the pulse sensor built into the power window regulator motor malfunctions, the power window control system enters fail-safe mode.


a.

The power window control system prohibits the following power window operations when the pulse sensor for the jam protection function has problems and the window position or the learned value is abnormal.

Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Power switch on (IG) Power switch off
(Key-off operation permitted)
Power switch off
(Key-off operation prohibited)
Manual up (Driver door window) X X -
Manual down (Driver door window) ○ X -
Auto up (Driver door window)
(hold switch at auto up position)
○* X -
Auto up (Driver door window) X X -
Auto down (Driver door window) X X -

HINT:
·

○: Operates

·

X: Operation prohibited

·

*: Operates in manual mode without jam protection



i.

Power window regulator master switch LED control

HINT:

During normal operation (fail-safe is not operating), or during fail-safe mode when there is a pulse sensor malfunction or the window position or learned value is abnormal, the LED illuminates as shown in the illustration.


1.

For driver door:

U181519E02
0.681,1.634 1.337,1.954 0.656,0.320 10 Key-off operation: 1.753,2.164 2.441,2.306 0.687,0.142 10 Prohibition 1.726,1.675 2.440,1.815 0.714,0.141 10 Permission 0.668,3.578 1.528,3.901 0.860,0.323 10 Window lock switch signal: 2.231,3.981 2.445,4.118 0.214,0.137 10 Off 2.231,3.548 2.445,3.730 0.214,0.181 10 On 0.668,2.677 1.037,2.815 0.369,0.137 10 LED: 1.87,3.159 2.442,3.310 0.571,0.151 10 Turns off 1.874,2.67 2.442,2.819 0.568,0.149 10 Turns on 0.66,0.648 1.585,0.797 0.924,0.149 10 Power switch: 2.231,1.178 2.445,1.316 0.214,0.138 10 Off 1.955,0.689 2.442,0.844 0.487,0.155 10 On (IG) 4.183,0.833 5.053,0.833 false 5.368,0.109 6.769,0.253 1.401,0.144 10 Approximately 43 sec. 0.223,0.118 1.639,0.279 1.416,0.161 10 Normal output pattern: 4.574,0.833 5.138,0.202 5.138,0.202 5.303,0.202 false



ii.

Fail-safe deactivation condition

When the pulse sensor is normal, to deactivate fail-safe mode, pull up the power window switch to the auto up position and hold it for at least 1 second to fully close the window from the fully open position. As a result, the auto up/down function will return.




b.

Initialization failure

HINT:

During initialization of the power window regulator motor ECU, when the window position or initialization complete status cannot be properly read from the EEPROM, the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Power switch on (IG) Power switch off
(Key-off operation permitted)
Power switch off
(Key-off operation prohibited)
Manual up (Driver door window) X X -
Manual down (Driver door window) ○ X -
Auto up (Driver door window)
(hold switch at auto up position)
○* X -
Auto up (Driver door window) X X -
Auto down (Driver door window) X X -

HINT:
·

○: Operates

·

X: Operation prohibited

·

*: Operates in manual mode without jam protection



i.

Power window regulator master switch LED control

HINT:

During initialization of the power window regulator motor ECU, when the window position or initialization complete status cannot be properly read from the EEPROM during fail-safe mode, the LED illuminates as shown in the illustration.


1.

For driver door:

U181520E02
0.724,3.597 1.579,3.915 0.855,0.318 10 Window lock switch signal: 2.251,3.944 2.465,4.090 0.214,0.146 10 Off 2.246,3.525 2.464,3.674 0.218,0.149 10 On 0.724,1.785 1.051,1.937 0.327,0.152 10 LED: 1.806,2.126 2.461,2.268 0.655,0.142 10 Turns off 1.884,1.665 2.461,1.811 0.577,0.146 10 Turns on 0.732,0.667 1.658,0.825 0.926,0.158 10 Power switch: 2.232,1.197 2.464,1.334 0.232,0.138 10 Off 1.971,0.666 2.462,0.816 0.492,0.150 10 On (IG) 0.181,0.137 2.289,0.279 2.109,0.142 10 Initialization failure output pattern: 3.131,2.212 3.131,3.331 false 3.275,2.211 3.275,2.589 false 3.42,2.211 3.42,2.939 false 4.007,2.209 4.007,3.35 false 3.575,2.209 3.575,3.35 false 2.581,3.109 3.084,3.109 false 3.962,3.11 3.628,3.11 false 3.575,3.109 3.131,3.109 false 2.581,2.752 3.084,2.752 false 3.546,2.752 3.471,2.752 false 2.581,2.39 3.084,2.39 false 3.399,2.39 3.324,2.39 false 3.278,2.39 3.13,2.39 false 4.066,3.498 4.584,3.692 0.518,0.194 10 1.5 sec. 2.59,3.138 3.108,3.332 0.518,0.194 10 1.5 sec. 2.59,2.78 3.108,2.974 0.518,0.194 10 1.0 sec. 2.59,2.417 3.108,2.612 0.518,0.194 10 0.5 sec. 3.42,2.752 3.131,2.752 false 4.053,3.58 3.968,3.58 3.968,3.58 3.765,3.11 false




c.

LIN communication failure

HINT:

If the LIN communication line malfunctions (communication stop), the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Power switch on (IG)
Manual up ○*
Manual down ○
Auto up (hold switch at auto up position) ○*
Auto up ○*
Auto down ○

HINT:
·

○: Operates

·

*: Jam protection can operate.




d.

LIN communication failure and pulse sensor failure

HINT:

If the LIN communication line malfunctions (communication stop) and the pulse sensor for the jam protection function has problems, the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Always
Manual up X
Manual down X
Auto up (hold switch at auto up position) X
Auto up X
Auto down X

HINT:
·

X: Operation prohibited

·

When the jam protection function does not operate due to a LIN communication failure, the manual up and auto up functions will not operate.




e.

LIN communication failure and abnormal window position learned value or initialization failure

HINT:

If the LIN communication line malfunctions (communication stop) and the window position or the learned value is abnormal, the power window control system prohibits operation as follows:


Power Window Regulator Master Switch Assembly
Power Window Operation Condition
Always
Manual up ○*
Manual down ○
Auto up (hold switch at auto up position) ○*
Auto up X
Auto down X

HINT:
·

○: Operates

·

X: Operation prohibited

·

*: Jam protection can operate and window reverses upon reaching the fully closed position.