Home › Vehicle Exterior › LIGHTING (EXT) › LIGHTING SYSTEM
RM2170E _59 Vehicle Exterior _057049 LIGHTING (EXT) _0278196 LIGHTING SYSTEM U

LIGHTING (EXT)  LIGHTING SYSTEM  FAIL-SAFE CHART  


LED HEADLIGHT SYSTEM


The light control ECU operates in fail-safe mode if an abnormal condition such as those listed below has been detected.

Item Abnormality Detection Condition Return Condition Master Warning Light Multi-information Display
Abnormal input voltage (High input voltage) Abnormal power source voltage (more than 17 V) is detected. Normal power source voltage (10 to 16 V) is detected. Flashes CHECK HEADLIGHT SYSTEM
Abnormal input voltage (Low input voltage)*1 If the power source voltage is too low (8.5 to 10 V), LED output current will be limited. (Headlights will remain illuminated.) Output current limit is canceled when the voltage returns to the specified operation voltage (10 to 16 V). Flashes CHECK HEADLIGHT SYSTEM
If the power source voltage is too low (7.1 to 8.5 V), headlight operation will stop. If the voltage returns to 8.5 V or more, headlight operation will resume.
Abnormal output
·

Open in output side circuit

·

Short between output terminal and body ground


Light control switch is turned off to head. Flashes CHECK HEADLIGHT SYSTEM

*1: When the headlights are on and the input voltage becomes between 6 and 10 V, the headlights dim.