84330
1.INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (TB) - 1 (E) | Hazard warning signal switch off | 10 kΩ or higher |
| Hazard warning signal switch on | Below 1 Ω |
| *a | Component without harness connected
(Hazard Warning Signal Switch Assembly) |
If the result is not as specified, replace the hazard warning signal switch assembly.
Illumination Inspection
Apply auxiliary battery voltage to the hazard warning signal switch assembly and check that the switch illuminates.
| Tester Connection | Specified Condition |
|---|---|
| Auxiliary battery positive (+) → Terminal 3 (ILL+)
Auxiliary battery negative (-) → Terminal 2 (ILL-) |
Illuminates |
| *a | Component without harness connected
(Hazard Warning Signal Switch Assembly) |
If the result is not as specified, replace the hazard warning signal switch assembly.