Home › Engine / Hybrid System › 1NZ-FXE EMISSION CONTROL › CANISTER(w/ Canister Pump Module) › from 2017.06
RM2170E _51 Engine / Hybrid System _057007 1NZ-FXE EMISSION CONTROL _0320446 CANISTER(w/ Canister Pump Module) G

1NZ-FXE EMISSION CONTROL  CANISTER(w/ Canister Pump Module)  INSPECTION  


PROCEDURE

Hide 77740 1.INSPECT CANISTER (CHARCOAL CANISTER ASSEMBLY)

a.

Visually check the canister (charcoal canister assembly).

i.
A267653

Visually check the canister (charcoal canister assembly) for cracks or damage.

If cracks or damage are found, replace the canister (charcoal canister assembly).



b.

Check canister (charcoal canister assembly) operation.

i.
U159053C01
0.771,0.156 0.885,0.156 0.885,0.156 1.146,0.646 false 0.792,1.219 1.01,1.219 1.01,1.219 1.156,1.125 false 1.344,2 1.219,2 1.219,2 1.063,1.552 false 0.594,0.083 0.719,0.229 0.125,0.146 10 false A 1.427,1.906 1.552,2.052 0.125,0.146 10 false B 0.604,1.125 0.729,1.271 0.125,0.146 10 false C 0.427,0.615 0.698,0.979 0.271,0.365 10 true *a
*a Air


With port C closed, blow 5 kPa (0.1 kgf/cm2, 0.7 psi) of air into port A, and check that air flows from port B.

If the result is not as specified, replace the canister (charcoal canister assembly).


ii.
U159054C01
1.417,0.146 1.271,0.146 1.271,0.146 1.135,0.646 false 1.313,2.01 1.167,2.01 1.167,2.01 1.052,1.552 false 0.563,0.76 0.688,0.76 0.688,0.76 1.125,1.042 false 1.49,0.063 1.615,0.208 0.125,0.146 10 false A 1.396,1.917 1.521,2.063 0.125,0.146 10 false B 0.375,0.667 0.5,0.813 0.125,0.146 10 false C 0.323,1.385 0.615,1.677 0.292,0.292 10 false *a
*a Air


With port A closed, blow 5 kPa (0.1 kgf/cm2, 0.7 psi) of air into port B, and check that air flows from port C.

If the result is not as specified, replace the canister (charcoal canister assembly).



c.

Check for air leaks.

i.
U159055C01
1.781,0.417 1.135,0.417 false 1.24,1.469 0.813,1.469 0.813,1.469 0.979,1.979 false 0.438,2.656 0.667,2.656 0.667,2.656 0.865,2.458 false 1.052,3.281 0.969,3.281 0.969,3.281 0.781,2.885 false 1.344,1.375 1.469,1.521 0.125,0.146 10 false A 1.135,3.188 1.26,3.333 0.125,0.146 10 false B 0.281,2.563 0.406,2.708 0.125,0.146 10 false C 0.948,0.323 1.229,0.646 0.281,0.323 10 false *a
*a Pressure Gauge


Connect a pressure gauge to port A of the canister (charcoal canister assembly).


ii.

With port C and port B closed, apply 20 kPa (150 mmHg, 5.91 in.Hg) of pressurized air into port A, then confirm that pressure is retained for 1 minute.

If the result is not as specified, replace the canister (charcoal canister assembly).



Hide 77745 2.INSPECT NO. 1 CHARCOAL CANISTER FILTER

a.

Visually check the No. 1 charcoal canister filter.

i.
A267658

Visually check the No. 1 charcoal canister filter for cracks or damage.

If cracks or damage are found, replace the charcoal canister with bracket assembly.



b.

Check canister operation.

i.
U159056C01
2.906,1.208 2.188,1.208 false 2.604,0.219 2.708,0.219 2.708,0.219 2.865,0.583 false 2.99,1.125 3.115,1.271 0.125,0.146 10 false A 2.427,0.135 2.552,0.281 0.125,0.146 10 false B 1.458,1.208 1.677,1.49 0.219,0.281 10 false *a
*a Air


Blow 0.5 kPa (0.005 kgf/cm2, 0.1 psi) of air into port A, and check that air flows from port B.

If the result is not as specified, replace the No. 1 charcoal canister filter.



c.

Check for air leaks.

i.
U159057C01
2.99,2.333 2.354,2.333 false 2.844,2.094 2.448,2.094 2.448,2.094 2.229,1.927 false 2.698,0.167 2.792,0.167 2.792,0.167 2.885,0.573 false 2.938,2 3.063,2.146 0.125,0.146 10 false A 2.531,0.083 2.656,0.229 0.125,0.146 10 false B 3.01,2.24 3.25,2.531 0.24,0.292 10 false *a
*a Pressure Gauge


Connect a pressure gauge to port A of the No. 1 charcoal canister filter.


ii.

With port B closed, apply 20 kPa (150 mmHg, 5.91 in.Hg) of pressurized air into port A, then confirm that pressure is retained for 1 minute.

If the result is not as specified, replace the No. 1 charcoal canister filter.



d.

Check the leak detection pump sub-assembly.

i.
A259522

Connect a positive (+) lead from the auxiliary battery to terminal 5 and a negative (-) lead to terminal 1.


ii.

Check that a clicking sound is heard from the leak detection pump sub-assembly.

If the result is not as specified, replace the leak detection pump sub-assembly.