1NZ-FXE EMISSION CONTROL  CANISTER(w/o Canister Pump Module)  INSPECTION  


PROCEDURE

Hide 1.CHECK CANISTER (FUEL SUCTION TUBE WITH PUMP AND GAUGE ASSEMBLY)

a.

Visually check the canister (fuel suction tube with pump and gauge assembly).

i.

Visually check the canister (fuel suction tube with pump and gauge assembly) for cracks or damage.

If cracks or damage are found, replace the canister (fuel suction tube with pump and gauge assembly).



b.

Inspect the ventilation of the canister (fuel suction tube with pump and gauge assembly).

i.
A345645C01
2.448,1.052 2.979,1.052 true 0.854,0.219 1.031,0.219 1.031,0.219 1.323,0.635 false 0.615,0.146 0.917,0.344 0.302,0.198 10 false *a 3.052,0.969 3.365,1.208 0.313,0.24 10 false *b 0.198,0.635 0.521,0.865 0.323,0.229 10 false *c
*a Port (A)
*b Port (B)
*c Air


Apply compressed air to the port (A) and check that the air flows out from the port (B).

OK:

The air flows from the port (B).



ii.
A345646C01
2.448,1.042 3.073,1.042 true 0.917,0.188 1.094,0.188 1.094,0.188 1.313,0.635 false 0.688,0.135 1.01,0.365 0.323,0.229 10 false *a 3.177,0.99 3.427,1.198 0.25,0.208 10 false *b 3.021,1.573 3.323,1.833 0.302,0.26 10 false *c
*a Port (A)
*b Port (B)
*c Air


Close the port (A), apply compressed air to the port (B).

OK:

Air does not flow at first. By gradually increasing the pressure, air flows when the pressure in the port reaches a certain level.



iii.
A345647C01
2.208,0.292 2.667,0.292 false 2.281,2.052 2.51,1.448 2.51,1.448 2.656,1.448 true 0.906,1.51 1.125,1.51 1.125,1.51 1.323,1.76 false 0.688,1.438 0.938,1.635 0.25,0.198 10 false *a 2.75,1.396 2.99,1.604 0.24,0.208 10 false *b 2.75,0.198 3.104,0.427 0.354,0.229 10 false *c
*a Port (A)
*b Port (B)
*c Vacuum Pump


Using a vacuum pump, apply vacuum to the port (B) with the port (A) closed.

OK:

The vacuum is maintained at first. By gradually increasing the vacuum, air flows and the vacuum decreases after the vacuum reaches a certain level.